7 Structure and Encoding of PDUs (7.3-7.5.1)
7.3 Address Part
7.3.1 General
Address parameters are distinguished by their location, immediately
following the fixed part of the PDU header. The address part is
illustrated below:
Octet
+--------------------------------------+
| |
| Destination Address Length Indicator | 10
| |
|--------------------------------------|
| | 11
| Destination Address |
| | m-1
|--------------------------------------|
| |
| Source Address Length Indicator | m
| |
|--------------------------------------|
| | m+1
| Source Address |
| | n-1
+--------------------------------------+
Figure 7-3. PDU header--Address Part
7.3.1.1 Destination and Source Address Information
The Destination and Source addresses are Network Service Access
Point addresses as defined in ISO 8348/DAD2, Addendum to the Network
Service Definition Covering Network Layer Addressing.
The Destination and Source Address information is of variable
length.
The Destination Address Length Indicator field specifies the length
of the Destination Address in number of octets. The Destination
Address field follows the Destination Address Length Indicator
field. The Source Address Length Indicator field specifies the
length of the Source Address in number of octets. The Source Address
Length Indicator field follows the Destination Address field. The
Source Address field follows the Source Address Length Indicator
field.
Each address parameter is encoded as follows:
Bits 8 7 6 5 4 3 2 1
+---------------------------------------------+
| Octet | Address parameter Length Indicator |
| n | (e.g., 'm') |
|---------------------------------------------|
| Octets | |
| n+1 | Address Parameter Value |
| thru | |
| n+m | |
+---------------------------------------------+
Table 7-2. Address Parameters
7.4 Segmentation Part
If the Segmentation Permitted Flag in the Fixed Part of the PDU Header
(Octet 4, Bit 8) is set to one, the segmentation part of the header,
illustrated below, must be present:
Octet
+------------------------+
| Data Unit Identifier | n,n+1
|------------------------|
| Segment Offset | n+2,n+3
|------------------------|
| Total Length | n+4,n+5
+------------------------+
Figure 7-4. PDU Header--Segmentation Part
Where the "Segmentation Permitted" flag is set to zero, the
nonsegmenting protocol subset is in use.
7.4.1 Data Unit Identifier
The Data Unit Identifier identifies an Initial PDU (and hence, its
Derived PDUs) so that a segmented data unit may be correctly
reassembled by the destination network-entity. The Data Unit
Identifier size is two octets.
7.4.2 Segment Offset
For each segment the Segment Offset field specifies the relative
position of the segment in the data part of the Initial PDU with
respect to the start of the data field. The offset is measured in
units of octets. The offset of the first segment is zero.
7.4.3 PDU Total Length
The Total Length field specifies the entire length of the Initial
PDU, including both the header and data. This field is not changed in
any segment (Derived PDU) for the lifetime of the PDU.
7.5 Options Part
7.5.1 General
The options part is used to convey optional parameters. If the
options part is present, it contains one or more parameters. The
number of parameters that may be contained in the options part is
indicated by the length of the options part which is:
PDU Header Length - (length of fixed part +
length of address part +
length of segmentation part).
The options part of the PDU header is illustrated below:
Octet
+--------------------+
| | n+6
| Options |
| | p
+--------------------+
Figure 7-5. PDU Header--Options Part
Each parameter contained within the options part of the PDU header is
encoded as follows:
BITS 8 7 6 5 4 3 2 1
+------------------------------------------+
| Octets | |
| n | Parameter Code |
|------------------------------------------|
| n+1 | Parameter Length (e.g., 'm') |
|------------------------------------------|
| n+2 | Parameter Value |
| n+m+1 | |
+------------------------------------------+
Table 7-3. Encoding of Parameters
The parameter code field is coded in binary and, without extensions,
provides a maximum number of 255 different parameters. However, as
noted below, bits 8 and 7 cannot take every possible value, so the
practical maximum number of different parameters is less. A parameter
code of 255 (binary 1111 1111) is reserved for possible extensions of
the parameter code.
The parameter length field indicates the length, in octets, of the
parameter value field. The length is indicated by a binary number,
'm', with a theoretical maximum value of 255. The practical maximum
value of 'm' is lower. For example, in the case of a single parameter
contained within the options part, two octets are required for the
parameter code and the parameter length indication itself. Thus, the
value of 'm' is limited to:
253 - (length of fixed part +
length of address part +
length of segmentation part).
For each succeeding parameter the maximum value of 'm' decreases.
The parameter value field contains the value of the parameter
identified in the parameter code field.
No parameter codes use bits 8 and 7 with the value 00.
Implementations shall accept the parameters defined in the options
part in any order. Duplication of options (where detected) is not
permitted. Receipt of a PDU with an option duplicated should be
treated as a protocol error. The rules governing the treatment of
protocol errors are described in Section 6.10, Error Reporting
Function.
The following parameters are permitted in the options part.