7 Structure and Encoding of PDUs (7.3-7.5.1)

 7.3 Address Part

  7.3.1 General

   Address parameters are distinguished by their location, immediately
   following the fixed part of the PDU header. The address part is
   illustrated below:

                                                      Octet
          +--------------------------------------+
          |                                      |
          | Destination Address Length Indicator |      10
          |                                      |
          |--------------------------------------|
          |                                      |      11
          |         Destination Address          |
          |                                      |      m-1
          |--------------------------------------|
          |                                      |
          |   Source Address Length Indicator    |       m
          |                                      |
          |--------------------------------------|
          |                                      |      m+1
          |           Source Address             |
          |                                      |      n-1
          +--------------------------------------+

                 Figure 7-3.  PDU header--Address Part

   7.3.1.1 Destination and Source Address Information

    The Destination and Source addresses are Network Service Access
    Point addresses as defined in ISO 8348/DAD2, Addendum to the Network
    Service Definition Covering Network Layer Addressing.

    The Destination and Source Address information is of variable
    length.

    The Destination Address Length Indicator field specifies the length
    of the Destination Address in number of octets. The Destination
    Address field follows the Destination Address Length Indicator
    field. The Source Address Length Indicator field specifies the
    length of the Source Address in number of octets. The Source Address
    Length Indicator field follows the Destination Address field. The
    Source Address field follows the Source Address Length Indicator
    field.

    Each address parameter is encoded as follows:

                      Bits   8   7   6   5   4   3   2   1
            +---------------------------------------------+
            | Octet  | Address parameter Length Indicator |
            |   n    |           (e.g., 'm')              |
            |---------------------------------------------|
            | Octets |                                    |
            |  n+1   |     Address Parameter Value        |
            | thru   |                                    |
            |  n+m   |                                    |
            +---------------------------------------------+

                     Table 7-2.  Address Parameters

 7.4 Segmentation Part

  If the Segmentation Permitted Flag in the Fixed Part of the PDU Header
  (Octet 4, Bit 8) is set to one, the segmentation part of the header,
  illustrated below, must be present:

                                               Octet
                +------------------------+
                |  Data Unit Identifier  |     n,n+1
                |------------------------|
                |     Segment Offset     |    n+2,n+3
                |------------------------|
                |      Total Length      |    n+4,n+5
                +------------------------+

               Figure 7-4.  PDU Header--Segmentation Part

  Where the "Segmentation Permitted" flag is set to zero, the
  nonsegmenting protocol subset is in use.

  7.4.1 Data Unit Identifier

   The Data Unit Identifier identifies an Initial PDU (and hence, its
   Derived PDUs) so that a segmented data unit may be correctly
   reassembled by the destination network-entity. The Data Unit
   Identifier size is two octets.

  7.4.2 Segment Offset

   For each segment the Segment Offset field specifies the relative
   position of the segment in the data part of the Initial PDU with
   respect to the start of the data field. The offset is measured in
   units of octets. The offset of the first segment is zero.

  7.4.3 PDU Total Length

   The Total Length field specifies the entire length of the Initial
   PDU, including both the header and data. This field is not changed in
   any segment (Derived PDU) for the lifetime of the PDU.

 7.5 Options Part

  7.5.1 General

   The options part is used to convey optional parameters. If the
   options part is present, it contains one or more parameters. The
   number of parameters that may be contained in the options part is
   indicated by the length of the options part which is:

    PDU Header Length - (length of fixed part +
                         length of address part +
                         length of segmentation part).

   The options part of the PDU header is illustrated below:

                                               Octet
                   +--------------------+
                   |                    |       n+6
                   |      Options       |
                   |                    |       p
                   +--------------------+

                 Figure 7-5.  PDU Header--Options Part

   Each parameter contained within the options part of the PDU header is
   encoded as follows:

                          BITS    8  7  6  5  4  3  2  1
             +------------------------------------------+
             |  Octets  |                               |
             |    n     |  Parameter Code               |
             |------------------------------------------|
             |   n+1    |  Parameter Length (e.g., 'm') |
             |------------------------------------------|
             |   n+2    |  Parameter Value              |
             |  n+m+1   |                               |
             +------------------------------------------+

                   Table 7-3.  Encoding of Parameters

   The parameter code field is coded in binary and, without extensions,
   provides a maximum number of 255 different parameters. However, as
   noted below, bits 8 and 7 cannot take every possible value, so the
   practical maximum number of different parameters is less. A parameter
   code of 255 (binary 1111 1111) is reserved for possible extensions of
   the parameter code.

   The parameter length field indicates the length, in octets, of the
   parameter value field. The length is indicated by a binary number,
   'm', with a theoretical maximum value of 255. The practical maximum
   value of 'm' is lower. For example, in the case of a single parameter
   contained within the options part, two octets are required for the
   parameter code and the parameter length indication itself. Thus, the
   value of 'm' is limited to:

     253 - (length of fixed part +
     length of address part +
     length of segmentation part).

   For each succeeding parameter the maximum value of 'm' decreases.

   The parameter value field contains the value of the parameter
   identified in the parameter code field.

   No parameter codes use bits 8 and 7 with the value 00.

   Implementations shall accept the parameters defined in the options
   part in any order. Duplication of options (where detected) is not
   permitted. Receipt of a PDU with an option duplicated should be
   treated as a protocol error. The rules governing the treatment of
   protocol errors are described in Section 6.10, Error Reporting
   Function.

   The following parameters are permitted in the options part.