Skip to main content

7 Structure and Encoding of PDUs (7.1-7.2)

 7.1 Structure

  All Protocol Data Units shall contain an integral number of octets.
  The octets in a PDU are numbered starting from one (1) and increasing
  in the order in which they are put into an SNSDU. The bits in an octet
  are numbered from one (1) to eight (8), where bit one (1) is the
  low-order bit.

  When consecutive octets are used to represent a binary number, the
  lower octet number has the most significant value.

  Any subnetwork supporting this protocol is required to state in its
  specification the way octets are transferred, using the terms "most
  significant bit" and "least significant bit." The PDUs of this
  protocol are defined using the terms "most significant bit" and "least
  significant bit."

   Note:

    When the encoding of a PDU is represented using a diagram in this
    section, the following representation is used:

     a)  octets are shown with the lowest numbered octet to the left,
         higher number octets being further to the right;

     b)  within an octet, bits are shown with bit eight (8) to the left
         and bit one (1) to the right.

  PDUs shall contain, in the following order:

   1)  the header, comprising:

    a)  the fixed part;

    b)  the address part;

    c)  the segmentation part, if present;

    d)  the options part, if present

   and

   2)  the data field, if present.

  This structure is illustrated below:

                       Part:                Described in:

            +-------------------+
            |    Fixed Part     |            Section 7.2
            +-------------------+

            +-------------------+
            |   Address Part    |            Section 7.3
            +-------------------+

            +-------------------+
            | Segmentation Part |            Section 7.4
            +-------------------+

            +-------------------+
            |   Options Part    |            Section 7.5
            +-------------------+

            +-------------------+
            |       Data        |            Section 7.6
            +-------------------+

                       Figure 7-1.  PDU Structure

 7.2 Fixed Part

  7.2.1 General

   The fixed part contains frequently occuring parameters including the
   type code (DT or ER) of the protocol data unit. The length and the
   structure of the fixed part are defined by the PDU code.

   The fixed part has the following format:

                                                      Octet
            +------------------------------------+
            | Network Layer Protocol Identifier  |     1
            |------------------------------------|
            |         Length Indicator           |     2
            |------------------------------------|
            |   Version/Protocol Id Extension    |     3
            |------------------------------------|
            |            Lifetime                |     4
            |------------------------------------|
            |S |M |E/R|         Type             |     5
            | P| S|   |                          |
            |------------------------------------|
            |          Segment Length            |    6,7
            |------------------------------------|
            |             Checksum               |    8,9
            +------------------------------------+

                  Figure 7-2.  PDU Header--Fixed Part

  7.2.2 Network Layer Protocol Identifier

   The value of this field shall be binary 1000 0001. This field
   identifies this Network Layer Protocol as ISO 8473, Protocol for
   Providing the Connectionless-mode Network Service.

  7.2.3 Length Indicator

   The length is indicated by a binary number, with a maximum value of
   254 (1111 1110). The length indicated is the length in octets of the
   header, as described in Section 7.1, Structure. The value 255 (1111
   1111) is reserved for possible future extensions.

    Note:

     The rules for forwarding and segmentation ensure that the header
     length is the same for all segments (Derived PDUs) of the Initial
     PDU, and is the same as the header length of the Initial PDU.

  7.2.4 Version/Protocol Identifier Extension

   The value of this field is binary 0000 0001. This Identifies a
   standard version of ISO 8473, Protocol for Providing the
   Connectionless-mode Network Service.

  7.2.5 PDU Lifetime

   The Lifetime field is encoded as a binary number representing the
   remaining lifetime of the PDU, in units of 500 milliseconds.

   The Lifetime field is set by the originating network-entity, and is
   decremented by every network-entity which processes the PDU. The PDU
   shall be discarded if the value of the field reaches zero.

   When a network-entity processes a PDU, it decrements the Lifetime by
   at least one. The Lifetime shall be decremented by more than one if
   the sum of:

    1)  the transit delay in the subnetwork from which the PDU was
        received; and

    2)  the delay within the system processing the PDU

   exceeds or is estimated to exceed 500 milliseconds. In this case, the
   lifetime field should be decremented by one for each additional 500
   milliseconds of delay. The determination of delay need not be
   precise, but where error exists the value used shall be an
   overestimate, not an underestimate.

   If the Lifetime reaches a value of zero before the PDU is delivered
   to the destination, the PDU shall be discarded. The Error Reporting
   function shall be invoked, as described in Section 6.10, Error
   Reporting Function, and may result in the generation of an ER PDU. It
   is a local matter whether the destination network-entity performs the
   Lifetime Control function.

   When the Segmentation function is applied to a PDU, the Lifetime
   field is copied into all of the Derived PDUs.

  7.2.6 Flags

   7.2.6.1 Segmentation Permitted and More Segments Flags

    The Segmentation Permitted flag determines whether segmentation is
    permitted. A value of one indicates that segmentation is permitted.

    A value of zero indicates that the non-segmenting protocol subset is
    employed. Where this is the case, the segmentation part of the PDU
    header is not present, and the Segment Length field serves as the
    Total Length field.

    The More Segments flag indicates whether the data segment in this
    PDU contains (as its last octet) the last octet of the User Data in
    the NSDU. When the More Segments flag is set to one (1) then
    segmentation has taken place and the last octet of the NSDU is not
    contained in this PDU. The More Segments flag cannot be set to one
    (1) if the Segmentation Permitted flag is not set to one (1).

    When the More Segments flag is set to zero (0) the last octet of the
    Data Part of the PDU is the last octet of the NSDU.

   7.2.6.2 Error Report Flag

    When the Error Report flag is set to one, the rules in Section 6.10
    are used to determine whether to generate an Error Report PDU upon
    discard of the PDU.

    When the Error Report flag is set to zero, discard of the PDU will
    not cause the generation of an Error Report PDU.

  7.2.7 Type Code

   The Type code field identifies the type of the protocol data unit.
   Allowed values are given in Table 7-1:

                                Bits    5 4 3 2 1
                    +-----------------------------+
                    |  DT PDU  |        1 1 1 0 0 |
                    |-----------------------------|
                    |  ER PDU  |        0 0 0 0 1 |
                    +-----------------------------+

                      Table 7-1.  Valid PDU Types

  7.2.8 PDU Segment Length

   The Segment Length field specifies the entire length of the PDU
   segment including both header and data, if present. When the full
   protocol is employed and a PDU is not segmented, then the value of
   this field is identical to the value of the Total Length field
   located in the Segmentation Part of the header.

   When the Non-segmenting protocol subset is employed, no segmentation
   part is present in the header. In this subset, the Segment Length
   field serves as the Total Length field of the header (see Section
   7.4.3).

  7.2.9 PDU Checksum

   The checksum is computed on the entire PDU header. This includes the
   segmentation and options parts, if present. A checksum value of zero
   is reserved to indicate that the checksum is to be ignored. The
   operation of the PDU Header Error Detection function ensures that the
   value zero does not represent a valid checksum. A non-zero value
   indicates that the checksum must be processed or the PDU must be
   discarded.