Skip to main content

2. The Control Protocol

Throughout this document the 12-bit MESSAGE-ID (see BBN Report 1822) is referred to as LINK (its 8 MSBs) and SUB-LINK (its 4 LSBs).

The control protocol starts with an initial connection phase on link 377 and continues on other links assigned at run time.

Four links are used for each voice communication:

Link L    will be used for control, from CALLER to ANSWERER.
Link K will be used for control, from ANSWERER to CALLER.
Link L+1 will be used for data, from CALLER to ANSWERER.
Link K+1 will be used for data, from ANSWERER to CALLER.

Both L and K should be between 340 and 375 (octal). L and K need not differ.

The first message (CALLER to ANSWERER) on link 377 indicates which user wants to talk to whom and specifies K. As a response (on K), the ANSWERER either refuses the call or accepts it and assigns L.

The CALLER then calls again (this time on link L). The ANSWERER initiates a negotiation session to verify the compatibility of the two parties.

The negotiation consists of suggestions put forth by one of the parties, which are either accepted or rejected by the other party. The suggesting party in the negotiation is called the NEGOTIATION MASTER. The other party is called the NEGOTIATION SLAVE. Usually the ANSWERER is the negotiation master, unless agreed otherwise by the method described later.

If the negotiation fails, either party may terminate the call by sending a "GOODBYE". If the negotiation is successfully ended, the ANSWERER rings bells to draw human attention and sends "RINGING" to the CALLER. When the call is answered (by a human), a "READY" is sent to the CALLER and the data starts flowing (on L+1 and K+1). However, a "READY" can be sent without a preceeding "RINGING".

This bell ringing occurs only after the initial call (not after renegotiation).

The assignment of L and K cannot be changed after the initial connection phase.

Only one control message can be sent in a network-message. Extra bits needed to fill the network-message are ignored.

The length of control messages should never exceed a single-packet (i.e., 1,007 data bits).

Control messages not recognized by their receiver should be ignored and should not cause any error condition resuting in termination of the connection. These messages may result from differences in implementation level between systems.

Summary of the Control Messages​

#1   "1,<WHO>,<WHOM>,K"

#2 "2,<CODE>" or only "2"

#3 "3,<WHAT>,<N>,<HOW(1),...HOW(N)>"

#4 "4,<WHAT>,<HOW>"

#5 "5,<WHAT>,<HOW>" or only "5,<WHAT>"

#6 "6,L" or only "6"

#7 "7"

#8 "8"

#9 "9"

#10 "10,<ID>"

#11 "11,<ID>"

#12 "12,<IM>"

#13 "13,<YM>,<OK>"