Appendix 2: Implementation Recommendations
-
It is recommended that the priority-bit be turned ON in the HOST/IMP header.
-
It is recommended that in all abbreviations, "R" be used for Receiver and "X" for Transmitter.
-
The following identifiers and values are recommended for implementations:
SLNCTH 30 SILENCE-THRESHOLD. Used for LONG-SILENCE definition. See below. Measured in the same units as GAIN, in its X-table.
TBS 1.000 sec TIME-BEGIN-SILENCE. LONG-SILENCE is declared if GAIN<SLNCTH for more than TBS.
TAS 0.500 sec TIME-AFTER-SILENCE. A delay introduced by the receiver after the end of LONG-SILENCE, before restarting the playback.
TES 0.150 sec TIME-END-SILENCE. The amount of time the transmitter backs up at the end of a LONG-SILENCE in order to ensure a smooth transition back to speech.
TRI 2.000 sec TIME-RESPONSE-INITIAL. Time for waiting for response for an initial call (#1 and #3). The initial call is repeated every TRI until an answer arrives, or until TRIGU expires.
TRIGU 20.000 sec TIME-RESPONSE-INITIAL-GIVEUP. If no response to an initial call is received within TRIGU after the FIRST initial call, the system gives up, assuming the other system is down.
TRQ 1.000 sec TIME-RESPONSE-INQUIRY. If no response to an inquiry (#8) is received within TRQ, the inquiry is repeated.
TRQGU 10.000 sec TIME-RESPONSE-INQUIRY-GIVEUP. If no response to an inquiry is received within TRQGU from the FIRST inquiry, the system gives up, assuming the other system is down.
TBDA 3.000 sec TIME-BETWEEN-DATA-ARRIVAL. If no data arrives within TBDA, an INQUIRY (#8) is sent. This repeats every TBDA.
TNR 2.000 sec TIME-NOT-READY. If the other system is in the NOT-READY (#7) state for more than TNR, an INQUIRY (#8) is sent. This repeats every TNR.
TNRGU 10.000 sec TIME-NOT-READY-GIVEUP. If the other system is in the NOT-READY (#7) state for more than TNRGU, then the system gives up, assuming the other system is down.
TBIN 3.000 sec TIME-BUFFER-IN. The input buffer size is equivalent to the time period TBIN (and its size is the DATA-RATE multiplied by the period TBIN). If the INPUT QUEUE ever gets to be longer than TBIN, data is discarded.
TBOUT 3.000 sec TIME-BUFFER-OUT. The output buffer size is equivalent to the time period TBOUT (and its size is the DATA-RATE multiplied by the period TBOUT). If the OUTPUT QUEUE ever gets to be longer than TBOUT, data is discarded.