PPP treats X.25 framing as a bit synchronous link. The link MUST be full-duplex, but MAY be either dedicated (permanent) or switched.

Interface Format

PPP presents an octet interface to the physical layer. There is no provision for sub-octets to be supplied or accepted.

Transmission Rate

PPP does not impose any restrictions regarding transmission rate, other than that of the particular X.25 interface.

Control Signals

Implementation of X.25 requires the provision of control signals, which indicate when the link has become connected or disconnected. These in turn provide the Up and Down events to the LCP state machine.

Because PPP does not normally require the use of control signals, the failure of such signals MUST NOT affect correct operation of PPP. Implications are discussed in [2].

Encoding

The definition of various encodings is the responsibility of the DTE/DCE equipment in use, and is outside the scope of this specification.

While PPP will operate without regard to the underlying representation of the bit stream, X.25 requires NRZ encoding.