3. The Data Link Layer
The Point-to-Point Protocol uses the principles, terminology, and frame structure of the International Organization For Standardization's (ISO) High-level Data Link Control (HDLC) procedures (ISO 3309-1979 [2]), as modified by ISO 3309:1984/PDAD1 "Addendum 1: Start/stop transmission" [5]. ISO 3309-1979 specifies the HDLC frame structure for use in synchronous environments. ISO 3309:1984/PDAD1 specifies proposed modifications to ISO 3309-1979 to allow its use in asynchronous environments.
The PPP control procedures use the definitions and Control field encodings standardized in ISO 4335-1979 [3] and ISO 4335-1979/Addendum 1-1979 [4]. The PPP frame structure is also consistent with CCITT Recommendation X.25 LAPB [6], since that too is based on HDLC.
The purpose of this memo is not to document what is already standardized in ISO 3309. We assume that the reader is already familiar with HDLC, or has access to a copy of [2] or [6]. Instead, this paper attempts to give a concise summary and point out specific options and features used by PPP. Since "Addendum 1: Start/stop transmission", is not yet standardized and widely available, it is summarized in Appendix A.
To remain consistent with standard Internet practice, and avoid confusion for people used to reading RFCs, all binary numbers in the following descriptions are in Most Significant Bit to Least Significant Bit order, reading from left to right, unless otherwise indicated. Note that this is contrary to standard ISO and CCITT practice which orders bits as transmitted (i.e., network bit order). Keep this in mind when comparing this document with the international standards documents.
3.1. Frame Format
A summary of the standard PPP frame structure is shown below. This figure does not include start/stop bits (for asynchronous links), nor any bits or octets inserted for transparency. The fields are transmitted from left to right.
+----------+----------+----------+----------+------------
| Flag | Address | Control | Protocol | Information
| 01111110 | 11111111 | 00000011 | 16 bits | *
+----------+----------+----------+----------+------------
---+----------+----------+-----------------
| FCS | Flag | Inter-frame Fill
| 16 bits | 01111110 | or next Address
---+----------+----------+-----------------
Inter-frame Time Fill
For asynchronous links, inter-frame time fill SHOULD be accomplished in the same manner as inter-octet time fill, by transmitting continuous "1" bits (mark-hold state).
For synchronous links, the Flag Sequence SHOULD be transmitted during inter-frame time fill. There is no provision for inter-octet time fill.
Implementation Note:
Mark idle (continuous ones) SHOULD NOT be used for idle synchronous inter-frame time fill. However, certain types of circuit-switched links require the use of mark idle, particularly those that calculate accounting based on bit activity. When mark idle is used on a synchronous link, the implementation MUST ensure at least 15 consecutive "1" bits between Flags, and that the Flag Sequence is generated at the beginning and end of a frame.
Flag Sequence
The Flag Sequence is a single octet and indicates the beginning or end of a frame. The Flag Sequence consists of the binary sequence 01111110 (hexadecimal 0x7e).
The Flag is a frame separator. Only one Flag is required between two frames. Two consecutive Flags constitute an empty frame, which is ignored.
Implementation Note:
The "shared zero mode" Flag Sequence "011111101111110" SHOULD NOT be used. When not avoidable, such an implementation MUST ensure that the first Flag Sequence detected (the end of the frame) is promptly communicated to the link layer.
Address Field
The Address field is a single octet and contains the binary sequence 11111111 (hexadecimal 0xff), the All-Stations address. PPP does not assign individual station addresses. The All-Stations address MUST always be recognized and received. The use of other address lengths and values may be defined at a later time, or by prior agreement. Frames with unrecognized Addresses SHOULD be silently discarded, and reported through the normal network management facility.
Control Field
The Control field is a single octet and contains the binary sequence 00000011 (hexadecimal 0x03), the Unnumbered Information (UI) command with the P/F bit set to zero. Frames with other Control field values SHOULD be silently discarded.
Protocol Field
The Protocol field is two octets and its value identifies the protocol encapsulated in the Information field of the frame.
This Protocol field is defined by PPP and is not a field defined by HDLC. However, the Protocol field is consistent with the ISO 3309 extension mechanism for Address fields. All Protocols MUST be odd; the least significant bit of the least significant octet MUST equal "1". Also, all Protocols MUST be assigned such that the least significant bit of the most significant octet equals "0". Frames received which don't comply with these rules MUST be considered as having an unrecognized Protocol, and handled as specified by the LCP. The Protocol field is transmitted and received most significant octet first.
Protocol field values in the "0---" to "3---" range identify the network-layer protocol of specific datagrams, and values in the "8---" to "b---" range identify datagrams belonging to the associated Network Control Protocols (NCPs), if any.
Protocol field values in the "4---" to "7---" range are used for protocols with low volume traffic which have no associated NCP. Protocol field values in the "c---" to "f---" range identify
datagrams as link-layer Control Protocols (such as LCP).
The most up-to-date values of the Protocol field are specified in the most recent "Assigned Numbers" RFC [11]. Current values are assigned as follows:
Value (in hex) Protocol Name
0001 to 001f reserved (transparency inefficient)
0021 Internet Protocol
0023 OSI Network Layer
0025 Xerox NS IDP
0027 DECnet Phase IV
0029 Appletalk
002b Novell IPX
002d Van Jacobson Compressed TCP/IP
002f Van Jacobson Uncompressed TCP/IP
0031 Bridging PDU
0033 Stream Protocol (ST-II)
0035 Banyan Vines
0037 reserved (until 1993)
00ff reserved (compression inefficient)
0201 802.1d Hello Packets
0231 Luxcom
0233 Sigma Network Systems
8021 Internet Protocol Control Protocol
8023 OSI Network Layer Control Protocol
8025 Xerox NS IDP Control Protocol
8027 DECnet Phase IV Control Protocol
8029 Appletalk Control Protocol
802b Novell IPX Control Protocol
802d Reserved
802f Reserved
8031 Bridging NCP
8033 Stream Protocol Control Protocol
8035 Banyan Vines Control Protocol
c021 Link Control Protocol
c023 Password Authentication Protocol
c025 Link Quality Report
c223 Challenge Handshake Authentication Protocol
Developers of new protocols MUST obtain a number from the Internet Assigned Numbers Authority (IANA), at [email protected].
Information Field
The Information field is zero or more octets. The Information field contains the datagram for the protocol specified in the Protocol field. The end of the Information field is found by locating the closing Flag Sequence and allowing two octets for the Frame Check Sequence field. The default maximum length of the Information field is 1500 octets. By negotiation, consenting PPP implementations may use other values for the maximum Information field length.
On transmission, the Information field may be padded with an arbitrary number of octets up to the maximum length. It is the responsibility of each protocol to disambiguate padding octets from real information.
Frame Check Sequence (FCS) Field
The Frame Check Sequence field is normally 16 bits (two octets). The use of other FCS lengths may be defined at a later time, or by prior agreement.
The FCS field is calculated over all bits of the Address, Control, Protocol and Information fields not including any start and stop bits (asynchronous) and any bits (synchronous) or octets (asynchronous) inserted for transparency. This does not include the Flag Sequences or the FCS field itself. The FCS is transmitted with the coefficient of the highest term first.
Note: When octets are received which are flagged in the Async-Control-Character-Map, they are discarded before calculating the FCS. See the description in Appendix A.
For more information on the specification of the FCS, see ISO 3309 [2] or CCITT X.25 [6].
Note: A fast, table-driven implementation of the 16-bit FCS algorithm is shown in Appendix B. This implementation is based on [7], [8], and [9].
Modifications to the Basic Frame Format
The Link Control Protocol can negotiate modifications to the standard PPP frame structure. However, modified frames will always be clearly distinguishable from standard frames.