跳到主要内容

6. Definitions

    RFC1271-MIB DEFINITIONS ::= BEGIN

        IMPORTS
            Counter                              FROM RFC1155-SMI
            DisplayString                        FROM RFC1158-MIB
            mib-2                                FROM RFC1213-MIB
            OBJECT-TYPE                          FROM RFC-1212;

    --  This MIB module uses the extended OBJECT-TYPE macro as
    --  defined in [9].


    --  Remote Network Monitoring MIB

        rmon    OBJECT IDENTIFIER ::= { mib-2 16 }


        -- textual conventions

        OwnerString ::= DisplayString
        -- This data type is used to model an administratively
        -- assigned name of the owner of a resource. This
        -- information is taken from the NVT ASCII character set.
        -- It is suggested that this name contain one or more
        -- of the following:
        -- IP address, management station name, network manager's
        -- name, location, or phone number.
        -- In some cases the agent itself will be the owner of
        -- an entry.  In these cases, this string shall be set
        -- to a string starting with 'monitor'.



        --
        -- SNMP access control is articulated entirely in terms of
        -- the contents of MIB views; access to a particular SNMP
        -- object instance depends only upon its presence or
        -- absence in a particular MIB view and never upon its
        -- value or the value of related object instances. Thus,
        -- objects of this type afford resolution of resource
        -- contention only among cooperating managers; they
        -- realize no access control function with respect
        -- to uncooperative parties.
        --
        -- By convention, objects with this syntax are declared
        -- as having
        --
        --      SIZE (0..127)


        EntryStatus ::= INTEGER
                   { valid(1),
                     createRequest(2),
                     underCreation(3),
                     invalid(4)
                   }

        -- The status of a table entry.
        --
        -- Setting this object to the value invalid(4) has the
        -- effect of invalidating the corresponding entry.
        -- That is, it effectively disassociates the mapping
        -- identified with said entry.
        -- It is an implementation-specific matter as to whether
        -- the agent removes an invalidated entry from the table.
        -- Accordingly, management stations must be prepared to
        -- receive tabular information from agents that corresponds
        -- to entries currently not in use.  Proper
        -- interpretation of such entries requires examination
        -- of the relevant EntryStatus object.
        --
        -- An existing instance of this object cannot be set to
        -- createRequest(2).  This object may only be set to
        -- createRequest(2) when this instance is created.  When
        -- this object is created, the agent may wish to create
        -- supplemental object instances to complete a conceptual
        -- row in this table.  Immediately after completing the
        -- create operation, the agent must set this object to
        -- underCreation(3).
        --
        -- Entries shall exist in the underCreation(3) state until



        -- the management station is finished configuring the
        -- entry and sets this object to valid(1) or aborts,
        -- setting this object to invalid(4).  If the agent
        -- determines that an entry has been in the
        -- underCreation(3) state for an abnormally long time,
        -- it may decide that the management station has
        -- crashed.  If the agent makes this decision,
        -- it may set this object to invalid(4) to reclaim the
        -- entry.  A prudent agent will understand that the
        -- management station may need to wait for human input
        -- and will allow for that possibility in its
        -- determination of this abnormally long period.


        statistics        OBJECT IDENTIFIER ::= { rmon 1 }
        history           OBJECT IDENTIFIER ::= { rmon 2 }
        alarm             OBJECT IDENTIFIER ::= { rmon 3 }
        hosts             OBJECT IDENTIFIER ::= { rmon 4 }
        hostTopN          OBJECT IDENTIFIER ::= { rmon 5 }
        matrix            OBJECT IDENTIFIER ::= { rmon 6 }
        filter            OBJECT IDENTIFIER ::= { rmon 7 }
        capture           OBJECT IDENTIFIER ::= { rmon 8 }
        event             OBJECT IDENTIFIER ::= { rmon 9 }


    -- The Statistics Group
    --
    -- Implementation of the Statistics group is optional.
    --
    -- The statistics group contains statistics measured by the
    -- probe for each monitored interface on this device.  These
    -- statistics take the form of free running counters that
    -- start from zero when a valid entry is created.
    --
    -- This group currently has statistics defined only for
    -- Ethernet interfaces.  Each etherStatsEntry contains
    -- statistics for one Ethernet interface.  The probe must
    -- create one etherStats entry for each monitored Ethernet
    -- interface on the device.

    etherStatsTable OBJECT-TYPE
        SYNTAX SEQUENCE OF EtherStatsEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of Ethernet statistics entries."
        ::= { statistics 1 }




    etherStatsEntry OBJECT-TYPE
        SYNTAX EtherStatsEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A collection of statistics kept for a particular
            Ethernet interface."
        INDEX { etherStatsIndex }
        ::= { etherStatsTable 1 }

    EtherStatsEntry ::= SEQUENCE {
        etherStatsIndex                    INTEGER (1..65535),
        etherStatsDataSource               OBJECT IDENTIFIER,
        etherStatsDropEvents               Counter,
        etherStatsOctets                   Counter,
        etherStatsPkts                     Counter,
        etherStatsBroadcastPkts            Counter,
        etherStatsMulticastPkts            Counter,
        etherStatsCRCAlignErrors           Counter,
        etherStatsUndersizePkts            Counter,
        etherStatsOversizePkts             Counter,
        etherStatsFragments                Counter,
        etherStatsJabbers                  Counter,
        etherStatsCollisions               Counter,
        etherStatsPkts64Octets             Counter,
        etherStatsPkts65to127Octets        Counter,
        etherStatsPkts128to255Octets       Counter,
        etherStatsPkts256to511Octets       Counter,
        etherStatsPkts512to1023Octets      Counter,
        etherStatsPkts1024to1518Octets     Counter,
        etherStatsOwner                    OwnerString,
        etherStatsStatus                   INTEGER
    }

    etherStatsIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The value of this object uniquely identifies this
            etherStats entry."
        ::= { etherStatsEntry 1 }

    etherStatsDataSource OBJECT-TYPE
        SYNTAX OBJECT IDENTIFIER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION



            "This object identifies the source of the data that
            this etherStats entry is configured to analyze.  This
            source can be any ethernet interface on this device.
            In order to identify a particular interface, this
            object shall identify the instance of the ifIndex
            object, defined in [4,6], for the desired interface.
            For example, if an entry were to receive data from
            interface #1, this object would be set to ifIndex.1.

            The statistics in this group reflect all packets
            on the local network segment attached to the
            identified interface.

            This object may not be modified if the associated
            etherStatsStatus object is equal to valid(1)."
        ::= { etherStatsEntry 2 }

    etherStatsDropEvents OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of events in which packets
            were dropped by the probe due to lack of resources.
            Note that this number is not necessarily the number of
            packets dropped; it is just the number of times this
            condition has been detected."
        ::= { etherStatsEntry 3 }

    etherStatsOctets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of octets of data (including
            those in bad packets) received on the
            network (excluding framing bits but including
            FCS octets)."
        ::= { etherStatsEntry 4 }

    etherStatsPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets (including error packets)
            received."
        ::= { etherStatsEntry 5 }



    etherStatsBroadcastPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of good packets received that were
            directed to the broadcast address."
        ::= { etherStatsEntry 6 }

    etherStatsMulticastPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of good packets received that were
            directed to a multicast address.  Note that this
            number does not include packets directed to the
            broadcast address."
        ::= { etherStatsEntry 7 }

    etherStatsCRCAlignErrors OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets received that
            had a length (excluding framing bits, but
            including FCS octets) of between 64 and 1518
            octets, inclusive, but were not an integral number
            of octets in length or had a bad Frame Check
            Sequence (FCS)."
        ::= { etherStatsEntry 8 }

    etherStatsUndersizePkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets received that were
            less than 64 octets long (excluding framing bits,
            but including FCS octets) and were otherwise well
            formed."
        ::= { etherStatsEntry 9 }

    etherStatsOversizePkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory



        DESCRIPTION
            "The total number of packets received that were
            longer than 1518 octets (excluding framing bits,
            but including FCS octets) and were otherwise
            well formed."
        ::= { etherStatsEntry 10 }

    etherStatsFragments OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets received that were not an
            integral number of octets in length or that had a bad
            Frame Check Sequence (FCS), and were less than 64
            octets in length (excluding framing bits but
            including FCS octets)."
        ::= { etherStatsEntry 11 }

    etherStatsJabbers OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets received that were
            longer than 1518 octets (excluding framing bits,
            but including FCS octets), and were not an
            integral number of octets in length or had
            a bad Frame Check Sequence (FCS)."
        ::= { etherStatsEntry 12 }

    etherStatsCollisions OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The best estimate of the total number of collisions
            on this Ethernet segment."
        ::= { etherStatsEntry 13 }

    etherStatsPkts64Octets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets (including error
            packets) received that were 64 octets in length
            (excluding framing bits but including FCS octets)."



        ::= { etherStatsEntry 14 }

    etherStatsPkts65to127Octets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets (including error
            packets) received that were between
            65 and 127 octets in length inclusive
            (excluding framing bits but including FCS octets)."
        ::= { etherStatsEntry 15 }

    etherStatsPkts128to255Octets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets (including error
            packets) received that were between
            128 and 255 octets in length inclusive
            (excluding framing bits but including FCS octets)."
        ::= { etherStatsEntry 16 }

    etherStatsPkts256to511Octets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets (including error
            packets) received that were between
            256 and 511 octets in length inclusive
            (excluding framing bits but including FCS octets)."
        ::= { etherStatsEntry 17 }

    etherStatsPkts512to1023Octets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets (including error
            packets) received that were between
            512 and 1023 octets in length inclusive
            (excluding framing bits but including FCS octets)."
        ::= { etherStatsEntry 18 }






    etherStatsPkts1024to1518Octets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets (including error
            packets) received that were between
            1024 and 1518 octets in length inclusive
            (excluding framing bits but including FCS octets)."
        ::= { etherStatsEntry 19 }

    etherStatsOwner OBJECT-TYPE
        SYNTAX OwnerString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is
            therefore using the resources assigned to it."
        ::= { etherStatsEntry 20 }

    etherStatsStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The status of this etherStats entry."
        ::= { etherStatsEntry 21 }


    -- The History Group

    -- Implementation of the History group is optional.
    --
    -- The history group records periodic statistical samples from
    -- a network and stores them for later retrieval.  The
    -- historyControl table stores configuration entries that each
    -- define an interface, polling period, and other parameters.
    -- Once samples are taken, their data is stored in an entry
    -- in a media-specific table.  Each such entry defines one
    -- sample, and is associated with the historyControlEntry that
    -- caused the sample to be taken.  Currently the only media-
    -- specific table defined is the etherHistoryTable, for
    -- Ethernet networks.
    --
    -- If the probe keeps track of the time of day, it should
    -- start the first sample of the history at a time such that
    -- when the next hour of the day begins, a sample is
    -- started at that instant.  This tends to make more



    -- user-friendly reports, and enables comparison of reports
    -- from different probes that have relatively accurate time
    -- of day.
    --
    -- The monitor is encouraged to add two history control entries
    -- per monitored interface upon initialization that describe
    -- a short term and a long term polling period.  Suggested
    -- parameters are 30 seconds for the short term polling
    -- period and 30 minutes for the long term period.

    historyControlTable OBJECT-TYPE
        SYNTAX SEQUENCE OF HistoryControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of history control entries."
        ::= { history 1 }

    historyControlEntry OBJECT-TYPE
        SYNTAX HistoryControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of parameters that set up a periodic
            sampling of statistics."
        INDEX { historyControlIndex }
        ::= { historyControlTable 1 }

    HistoryControlEntry ::= SEQUENCE {
        historyControlIndex             INTEGER (1..65535),
        historyControlDataSource        OBJECT IDENTIFIER,
        historyControlBucketsRequested  INTEGER (1..65535),
        historyControlBucketsGranted    INTEGER (1..65535),
        historyControlInterval          INTEGER (1..3600),
        historyControlOwner             OwnerString,
        historyControlStatus            INTEGER
    }

    historyControlIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry in the
            historyControl table.  Each such entry defines a
            set of samples at a particular interval for an
            interface on the device."
        ::= { historyControlEntry 1 }



    historyControlDataSource OBJECT-TYPE
        SYNTAX OBJECT IDENTIFIER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This object identifies the source of the data for
            which historical data was collected and
            placed in a media-specific table on behalf of this
            historyControlEntry.  This source can be any
            interface on this device.  In order to identify
            a particular interface, this object shall identify
            the instance of the ifIndex object, defined
            in [4,6], for the desired interface.  For example,
            if an entry were to receive data from interface #1,
            this object would be set to ifIndex.1.

            The statistics in this group reflect all packets
            on the local network segment attached to the
            identified interface.

            This object may not be modified if the associated
            historyControlStatus object is equal to valid(1)."
        ::= { historyControlEntry 2 }

    historyControlBucketsRequested OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The requested number of discrete time intervals
            over which data is to be saved in the part of the
            media-specific table associated with this
            historyControl entry.

            When this object is created or modified, the probe
            should set historyControlBucketsGranted as closely to
            this object as is possible for the particular probe
            implementation and available resources."
        DEFVAL { 50 }
        ::= { historyControlEntry 3 }

    historyControlBucketsGranted OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of discrete sampling intervals
            over which data shall be saved in the part of



            the media-specific table associated with this
            historyControl entry.

            When the associated historyControlBucketsRequested
            object is created or modified, the probe
            should set this object as closely to the requested
            value as is possible for the particular
            probe implementation and available resources.  The
            probe must not lower this value except as a result
            of a modification to the associated
            historyControlBucketsRequested object.

            There will be times when the actual number of
            buckets associated with this entry is less than
            the value of this object.  In this case, at the
            end of each sampling interval, a new bucket will
            be added to the media-specific table.

            When the number of buckets reaches the value of
            this object and a new bucket is to be added to the
            media-specific table, the oldest bucket associated
            with this historyControlEntry shall be deleted by
            the agent so that the new bucket can be added.

            When the value of this object changes to a value less
            than the current value, entries are deleted
            from the media-specific table associated with this
            historyControlEntry.  Enough of the oldest of these
            entries shall be deleted by the agent so that their
            number remains less than or equal to the new value of
            this object.

            When the value of this object changes to a value
            greater than the current value, the number of
            associated media-specific entries may be allowed
            to grow."
        ::= { historyControlEntry 4 }

    historyControlInterval OBJECT-TYPE
        SYNTAX INTEGER (1..3600)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The interval in seconds over which the data is
            sampled for each bucket in the part of the
            media-specific table associated with this
            historyControl entry.  This interval can
            be set to any number of seconds between 1 and



            3600 (1 hour).

            Because the counters in a bucket may overflow at their
            maximum value with no indication, a prudent manager
            will take into account the possibility of overflow
            in any of the associated counters.  It is important
            to consider the minimum time in which any counter
            could overflow on a particular media type and set
            the historyControlInterval object to a value less
            than this interval.  This is typically most
            important for the 'octets' counter in any
            media-specific table.  For example, on an Ethernet
            network, the etherHistoryOctets counter could overflow
            in about one hour at the Ethernet's maximum
            utilization.

            This object may not be modified if the associated
            historyControlStatus object is equal to valid(1)."
        DEFVAL { 1800 }
        ::= { historyControlEntry 5 }

    historyControlOwner OBJECT-TYPE
        SYNTAX OwnerString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is therefore
            using the resources assigned to it."
        ::= { historyControlEntry 6 }

    historyControlStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The status of this historyControl entry.

            Each instance of the media-specific table associated
            with this historyControlEntry will be deleted by the
            agent if this historyControlEntry is not equal to
            valid(1)."
        ::= { historyControlEntry 7 }


    -- Ether History table

    etherHistoryTable OBJECT-TYPE
        SYNTAX SEQUENCE OF EtherHistoryEntry



        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of Ethernet history entries."
        ::= { history 2 }

    etherHistoryEntry OBJECT-TYPE
        SYNTAX EtherHistoryEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "An historical sample of Ethernet statistics on a
            particular Ethernet interface.  This sample is
            associated with the historyControlEntry which set
            up the parameters for a regular collection of these
            samples."
        INDEX { etherHistoryIndex , etherHistorySampleIndex }
        ::= { etherHistoryTable 1 }

    EtherHistoryEntry ::= SEQUENCE {
        etherHistoryIndex                 INTEGER (1..65535),
        etherHistorySampleIndex           INTEGER,
        etherHistoryIntervalStart         TimeTicks,
        etherHistoryDropEvents            Counter,
        etherHistoryOctets                Counter,
        etherHistoryPkts                  Counter,
        etherHistoryBroadcastPkts         Counter,
        etherHistoryMulticastPkts         Counter,
        etherHistoryCRCAlignErrors        Counter,
        etherHistoryUndersizePkts         Counter,
        etherHistoryOversizePkts          Counter,
        etherHistoryFragments             Counter,
        etherHistoryJabbers               Counter,
        etherHistoryCollisions            Counter,
        etherHistoryUtilization           INTEGER (0..10000)
    }

    etherHistoryIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The history of which this entry is a part.  The
            history identified by a particular value of this
            index is the same history as identified
            by the same value of historyControlIndex."
        ::= { etherHistoryEntry 1 }




    etherHistorySampleIndex OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies the particular
            sample this entry represents among all samples
            associated with the same historyControlEntry.
            This index starts at 1 and increases by one
            as each new sample is taken."
        ::= { etherHistoryEntry 2 }

    etherHistoryIntervalStart OBJECT-TYPE
        SYNTAX TimeTicks
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The value of sysUpTime at the start of the interval
            over which this sample was measured.  If the probe
            keeps track of the time of day, it should start
            the first sample of the history at a time such that
            when the next hour of the day begins, a sample is
            started at that instant.  Note that following this
            rule may require the probe to delay collecting the
            first sample of the history, as each sample must be
            of the same interval.  Also note that the sample which
            is currently being collected is not accessible in this
            table until the end of its interval."
        ::= { etherHistoryEntry 3 }

    etherHistoryDropEvents OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of events in which packets
            were dropped by the probe due to lack of resources
            during this interval.  Note that this number is not
            necessarily the number of packets dropped, it is just
            the number of times this condition has been detected."
        ::= { etherHistoryEntry 4 }

    etherHistoryOctets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of octets of data (including



            those in bad packets) received on the
            network (excluding framing bits but including
            FCS octets)."
        ::= { etherHistoryEntry 5 }

    etherHistoryPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets (including error packets)
            received during this sampling interval."
        ::= { etherHistoryEntry 6 }

    etherHistoryBroadcastPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of good packets received during this
            sampling interval that were directed to the
            broadcast address."
        ::= { etherHistoryEntry 7 }

    etherHistoryMulticastPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of good packets received during this
            sampling interval that were directed to a
            multicast address.  Note that this number does not
            include packets addressed to the broadcast address."
        ::= { etherHistoryEntry 8 }

    etherHistoryCRCAlignErrors OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets received during this
            sampling interval that had a length (excluding
            framing bits but including FCS octets) between
            64 and 1518 octets, inclusive, but were not an
            integral number of octets in length or had a
            bad Frame Check Sequence (FCS)."
        ::= { etherHistoryEntry 9 }




    etherHistoryUndersizePkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets received during this
            interval that were less than 64 octets long
            (excluding framing bits but including FCS
            octets) and were otherwise well formed."
        ::= { etherHistoryEntry 10 }

    etherHistoryOversizePkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets received during this
            interval that were longer than 1518 octets
            (excluding framing bits but including FCS
            octets) but were otherwise well formed."
        ::= { etherHistoryEntry 11 }

    etherHistoryFragments OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total number of packets received during this
            sampling interval that were not an integral
            number of octets in length or that
            had a bad Frame Check Sequence (FCS), and
            were less than 64 octets in length (excluding
            framing bits but including FCS octets)."
        ::= { etherHistoryEntry 12 }

    etherHistoryJabbers OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets received during this
            interval that were longer than 1518 octets
            (excluding framing bits but including FCS octets),
            and were not an integral number of octets in
            length or had a bad Frame Check Sequence (FCS)."
        ::= { etherHistoryEntry 13 }





    etherHistoryCollisions OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The best estimate of the total number of collisions
            on this Ethernet segment during this interval."
        ::= { etherHistoryEntry 14 }

    etherHistoryUtilization OBJECT-TYPE
        SYNTAX INTEGER (0..10000)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The best estimate of the mean physical layer
            network utilization on this interface during this
            interval, in hundredths of a percent."
        ::= { etherHistoryEntry 15 }


    -- The Alarm Group

    -- Implementation of the Alarm group is optional.
    --
    -- The Alarm Group requires the implementation of the Event
    -- group.
    --
    -- The Alarm group periodically takes statistical samples from
    -- variables in the probe and compares them to thresholds
    -- that have been configured.  The alarm table stores
    -- configuration entries that each define a variable,
    -- polling period, and threshold parameters.  If a sample is
    -- found to cross the threshold values, an event is
    -- generated.  Only variables that resolve to an ASN.1
    -- primitive type of INTEGER (INTEGER, Counter,
    -- Gauge, or TimeTicks) may be monitored in this way.
    --
    -- This function has a hysteresis mechanism to limit the
    -- generation of events.  This mechanism generates one event
    -- as a threshold is crossed in the appropriate direction.
    -- No more events are generated for that threshold until the
    -- opposite threshold is crossed.
    --
    -- In the case of a sampling a deltaValue, a probe may
    -- implement this mechanism with more precision if it takes
    -- a delta sample twice per period, each time comparing the
    -- sum of the latest two samples to the threshold.  This
    -- allows the detection of threshold crossings



    -- that span the sampling boundary.  Note that this does not
    -- require any special configuration of the threshold value.
    -- It is suggested that probes implement this more precise
    -- algorithm.

    alarmTable OBJECT-TYPE
        SYNTAX SEQUENCE OF AlarmEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of alarm entries."
        ::= { alarm 1 }

    alarmEntry OBJECT-TYPE
        SYNTAX AlarmEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of parameters that set up a periodic checking
            for alarm conditions."
        INDEX { alarmIndex }
        ::= { alarmTable 1 }

    AlarmEntry ::= SEQUENCE {
        alarmIndex                    INTEGER (1..65535),
        alarmInterval                 INTEGER,
        alarmVariable                 OBJECT IDENTIFIER,
        alarmSampleType               INTEGER,
        alarmValue                    INTEGER,
        alarmStartupAlarm             INTEGER,
        alarmRisingThreshold          INTEGER,
        alarmFallingThreshold         INTEGER,
        alarmRisingEventIndex         INTEGER (1..65535),
        alarmFallingEventIndex        INTEGER (1..65535),
        alarmOwner                    OwnerString,
        alarmStatus                   INTEGER
    }

    alarmIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry in the
            alarm table.  Each such entry defines a
            diagnostic sample at a particular interval
            for an object on the device."
        ::= { alarmEntry 1 }



    alarmInterval OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The interval in seconds over which the data is
            sampled and compared with the rising and falling
            thresholds.  When setting this variable, care
            should be given to ensure that the variable being
            monitored will not exceed 2^31 - 1 and roll
            over the alarmValue object during the interval.

            This object may not be modified if the associated
            alarmStatus object is equal to valid(1)."
        ::= { alarmEntry 2 }

    alarmVariable OBJECT-TYPE
        SYNTAX OBJECT IDENTIFIER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The object identifier of the particular variable to
            be sampled.  Only variables that resolve to an ASN.1
            primitive type of INTEGER (INTEGER, Counter, Gauge,
            or TimeTicks) may be sampled.

            Because SNMP access control is articulated entirely
            in terms of the contents of MIB views, no access
            control mechanism exists that can restrict the value of
            this object to identify only those objects that exist
            in a particular MIB view.  Because there is thus no
            acceptable means of restricting the read access that
            could be obtained through the alarm mechanism, the
            probe must only grant write access to this object in
            those views that have read access to all objects on
            the probe.

            During a set operation, if the supplied variable
            name is not available in the selected MIB view, a
            badValue error must be returned.  If at any time
            the variable name of an established alarmEntry is
            no longer available in the selected MIB view, the
            probe must change the status of this alarmEntry
            to invalid(4).

            This object may not be modified if the associated
            alarmStatus object is equal to valid(1)."
        ::= { alarmEntry 3 }



    alarmSampleType OBJECT-TYPE
        SYNTAX INTEGER {
            absoluteValue(1),
            deltaValue(2)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The method of sampling the selected variable and
            calculating the value to be compared against the
            thresholds.  If the value of this object is
            absoluteValue(1), the value of the selected variable
            will be compared directly with the thresholds at the
            end of the sampling interval.  If the value of this
            object is deltaValue(2), the value of the selected
            variable at the last sample will be subtracted from
            the current value, and the difference compared with
            the thresholds.

            This object may not be modified if the associated
            alarmStatus object is equal to valid(1)."
        ::= { alarmEntry 4 }

    alarmValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The value of the statistic during the last sampling
            period.  The value during the current sampling period
            is not made available until the period is completed."
        ::= { alarmEntry 5 }

    alarmStartupAlarm OBJECT-TYPE
        SYNTAX INTEGER {
            risingAlarm(1),
            fallingAlarm(2),
            risingOrFallingAlarm(3)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The alarm that may be sent when this entry is first
            set to valid.  If the first sample after this entry
            becomes valid is greater than or equal to the
            risingThreshold and alarmStartupAlarm is equal to
            risingAlarm(1) or risingOrFallingAlarm(3), then a
            single rising alarm will be generated.  If the first



            sample after this entry becomes valid is less than
            or equal to the fallingThreshold and
            alarmStartupAlarm is equal to fallingAlarm(2) or
            risingOrFallingAlarm(3), then a single falling
            alarm will be generated.

            This object may not be modified if the associated
            alarmStatus object is equal to valid(1)."
        ::= { alarmEntry 6 }

    alarmRisingThreshold OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "A threshold for the sampled statistic.  When the
            current sampled value is greater than or equal to
            this threshold, and the value at the last sampling
            interval was less than this threshold, a single
            event will be generated.
            A single event will also be generated if the first
            sample after this entry becomes valid is greater
            than or equal to this threshold and the associated
            alarmStartupAlarm is equal to risingAlarm(1) or
            risingOrFallingAlarm(3).

            After a rising event is generated, another such event
            will not be generated until the sampled value
            falls below this threshold and reaches the
            alarmFallingThreshold.

            This object may not be modified if the associated
            alarmStatus object is equal to valid(1)."
        ::= { alarmEntry 7 }

    alarmFallingThreshold OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "A threshold for the sampled statistic.  When the
            current sampled value is less than or equal to
            this threshold, and the value at the last sampling
            interval was greater than this threshold, a single
            event will be generated.
            A single event will also be generated if the first
            sample after this entry becomes valid is less than or
            equal to this threshold and the associated



            alarmStartupAlarm is equal to fallingAlarm(2) or
            risingOrFallingAlarm(3).

            After a falling event is generated, another such event
            will not be generated until the sampled value
            rises above this threshold and reaches the
            alarmRisingThreshold.

            This object may not be modified if the associated
            alarmStatus object is equal to valid(1)."
        ::= { alarmEntry 8 }

    alarmRisingEventIndex OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The index of the eventEntry that is
            used when a rising threshold is crossed.  The
            eventEntry identified by a particular value of
            this index is the same as identified by the same value
            of the eventIndex object.  If there is no
            corresponding entry in the eventTable, then
            no association exists.  In particular, if this value
            is zero, no associated event will be generated, as
            zero is not a valid event index.

            This object may not be modified if the associated
            alarmStatus object is equal to valid(1)."
        ::= { alarmEntry 9 }

    alarmFallingEventIndex OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The index of the eventEntry that is
            used when a falling threshold is crossed.  The
            eventEntry identified by a particular value of
            this index is the same as identified by the same value
            of the eventIndex object.  If there is no
            corresponding entry in the eventTable, then
            no association exists.  In particular, if this value
            is zero, no associated event will be generated, as
            zero is not a valid event index.

            This object may not be modified if the associated
            alarmStatus object is equal to valid(1)."



        ::= { alarmEntry 10 }

    alarmOwner OBJECT-TYPE
        SYNTAX OwnerString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is
            therefore using the resources assigned to it."
        ::= { alarmEntry 11 }

    alarmStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The status of this alarm entry."
        ::= { alarmEntry 12 }


    -- The Host Group

    -- Implementation of the Host group is optional.
    --
    -- The host group discovers new hosts on the network by
    -- keeping a list of source and destination MAC Addresses seen
    -- in good packets.  For each of these addresses, the host
    -- group keeps a set of statistics.  The hostControlTable
    -- controls which interfaces this function is performed on,
    -- and contains some information about the process.  On
    -- behalf of each hostControlEntry, data is collected on an
    -- interface and placed both the hostTable and the
    -- hostTimeTable.  If the monitoring device finds itself
    -- short of resources, it may delete entries as needed.  It
    -- is suggested that the device delete the least recently
    -- used entries first.

    -- The hostTable contains entries for each address
    -- discovered on a particular interface.  Each entry
    -- contains statistical data about that host.  This table
    -- is indexed by the MAC address of the host, through
    -- which a random access may be achieved.

    -- The hostTimeTable contains data in the same format as the
    -- hostTable, and must contain the same set of hosts, but is
    -- indexed using hostTimeCreationOrder rather than hostAddress.
    -- The hostTimeCreationOrder is an integer which reflects
    -- the relative order in which a particular entry was



    -- discovered and thus inserted into the table.  As this
    -- order, and thus index, is among those entries currently
    -- in the table, the index for a particular entry may change
    -- if an (earlier) entry is deleted.  Thus the association
    -- between hostTimeCreationOrder and hostTimeEntry may be
    -- broken at any time.

    -- The hostTimeTable has two important uses.  The first is the
    -- fast download of this potentially large table.  Because the
    -- index of this table runs from 1 to the size of the table,
    -- inclusive, its values are predictable.  This allows very
    -- efficient packing of variables into SNMP PDU's and allows
    -- a table transfer to have multiple packets outstanding.
    -- These benefits increase transfer rates tremendously.

    -- The second use of the hostTimeTable is the efficient
    -- discovery by the management station of new entries added
    -- to the table.  After the management station has
    -- downloaded the entire table, it knows that new entries
    -- will be added immediately after the end of the current
    -- table.  It can thus detect new entries there
    -- and retrieve them easily.

    -- Because the association between hostTimeCreationOrder and
    -- hostTimeEntry may be broken at any time, the management
    -- station must monitor the related hostControlLastDeleteTime
    -- object.  When the management station thus detects a deletion,
    -- it must assume that any such associations have been broken,
    -- and invalidate any it has stored locally.  This includes
    -- restarting any download of the hostTimeTable that may have
    -- been in progress, as well as rediscovering the end of the
    -- hostTimeTable so that it may detect new entries.  If the
    -- management station does not detect the broken association,
    -- it may continue to refer to a particular host by its
    -- creationOrder while unwittingly retrieving the data
    -- associated with another host entirely.  If this happens
    -- while downloading the host table, the management station
    -- may fail to download all of the entries in the table.


    hostControlTable OBJECT-TYPE
        SYNTAX SEQUENCE OF HostControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of host table control entries."
        ::= { hosts 1 }




    hostControlEntry OBJECT-TYPE
        SYNTAX HostControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of parameters that set up the discovery of
            hosts on a particular interface and the collection
            of statistics about these hosts."
        INDEX { hostControlIndex }
        ::= { hostControlTable 1 }

    HostControlEntry ::= SEQUENCE {
        hostControlIndex            INTEGER (1..65535),
        hostControlDataSource       OBJECT IDENTIFIER,
        hostControlTableSize        INTEGER,
        hostControlLastDeleteTime   TimeTicks,
        hostControlOwner            OwnerString,
        hostControlStatus           INTEGER
    }

    hostControlIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry in the
            hostControl table.  Each such entry defines
            a function that discovers hosts on a particular
            interface and places statistics about them in the
            hostTable and the hostTimeTable on behalf of this
            hostControlEntry."
        ::= { hostControlEntry 1 }

    hostControlDataSource OBJECT-TYPE
        SYNTAX OBJECT IDENTIFIER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This object identifies the source of the data for
            this instance of the host function.  This source
            can be any interface on this device.  In order
            to identify a particular interface, this object shall
            identify the instance of the ifIndex object, defined
            in [4,6], for the desired interface.  For example,
            if an entry were to receive data from interface #1,
            this object would be set to ifIndex.1.

            The statistics in this group reflect all packets



            on the local network segment attached to the
            identified interface.

            This object may not be modified if the associated
            hostControlStatus object is equal to valid(1)."
        ::= { hostControlEntry 2 }

    hostControlTableSize OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of hostEntries in the hostTable and the
            hostTimeTable associated with this hostControlEntry."
        ::= { hostControlEntry 3 }

    hostControlLastDeleteTime OBJECT-TYPE
        SYNTAX TimeTicks
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The value of sysUpTime when the last entry
            was deleted from the portion of the hostTable
            associated with this hostControlEntry.  If no
            deletions have occurred, this value shall be zero."
        ::= { hostControlEntry 4 }

    hostControlOwner OBJECT-TYPE
        SYNTAX OwnerString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is
            therefore using the resources assigned to it."
        ::= { hostControlEntry 5 }

    hostControlStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The status of this hostControl entry.

            If this object is not equal to valid(1), all
            associated entries in the hostTable,
            hostTimeTable, and the hostTopNTable shall be
            deleted by the agent."
        ::= { hostControlEntry 6 }



    hostTable OBJECT-TYPE
        SYNTAX SEQUENCE OF HostEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of host entries."
        ::= { hosts 2 }

    hostEntry OBJECT-TYPE
        SYNTAX HostEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A collection of statistics for a particular host
            that has been discovered on an interface of this
            device."
        INDEX { hostIndex, hostAddress }
        ::= { hostTable 1 }

    HostEntry ::= SEQUENCE {
        hostAddress             OCTET STRING,
        hostCreationOrder       INTEGER (1..65535),
        hostIndex               INTEGER (1..65535),
        hostInPkts              Counter,
        hostOutPkts             Counter,
        hostInOctets            Counter,
        hostOutOctets           Counter,
        hostOutErrors           Counter,
        hostOutBroadcastPkts    Counter,
        hostOutMulticastPkts    Counter
    }

    hostAddress OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The physical address of this host."
        ::= { hostEntry 1 }

    hostCreationOrder OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that defines the relative ordering of
            the creation time of hosts captured for a
            particular hostControlEntry.  This index shall



            be between 1 and N, where N is the value of
            the associated hostControlTableSize.  The ordering
            of the indexes is based on the order of each entry's
            insertion into the table, in which entries added
            earlier have a lower index value than entries added
            later.

            It is important to note that the order for a
            particular entry may change as an (earlier) entry
            is deleted from the table.  Because this order may
            change, management stations should make use of the
            hostControlLastDeleteTime variable in the
            hostControlEntry associated with the relevant
            portion of the hostTable.  By observing
            this variable, the management station may detect
            the circumstances where a previous association
            between a value of hostCreationOrder
            and a hostEntry may no longer hold."
        ::= { hostEntry 2 }

    hostIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The set of collected host statistics of which
            this entry is a part.  The set of hosts
            identified by a particular value of this
            index is associated with the hostControlEntry
            as identified by the same value of hostControlIndex."
        ::= { hostEntry 3 }

    hostInPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets without errors transmitted to
            this address since it was added to the hostTable."
        ::= { hostEntry 4 }

    hostOutPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets including errors transmitted
            by this address since it was added to the hostTable."



        ::= { hostEntry 5 }

    hostInOctets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of octets transmitted to this address
            since it was added to the hostTable (excluding
            framing bits but including FCS octets), except for
            those octets in packets that contained errors."
        ::= { hostEntry 6 }

    hostOutOctets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of octets transmitted by this address
            since it was added to the hostTable (excluding
            framing bits but including FCS octets), including
            those octets in packets that contained errors."
        ::= { hostEntry 7 }

    hostOutErrors OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of error packets transmitted by this
            address since this host was added to the hostTable."
        ::= { hostEntry 8 }

    hostOutBroadcastPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of good packets transmitted by this
            address that were directed to the broadcast address
            since this host was added to the hostTable."
        ::= { hostEntry 9 }

    hostOutMulticastPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION



            "The number of good packets transmitted by this
            address that were directed to a multicast address
            since this host was added to the hostTable.
            Note that this number does not include packets
            directed to the broadcast address."
        ::= { hostEntry 10 }


    -- host Time Table

    hostTimeTable OBJECT-TYPE
        SYNTAX SEQUENCE OF HostTimeEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of time-ordered host table entries."
        ::= { hosts 3 }

    hostTimeEntry OBJECT-TYPE
        SYNTAX HostTimeEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A collection of statistics for a particular host
            that has been discovered on an interface of this
            device.  This collection includes the relative
            ordering of the creation time of this object."
        INDEX { hostTimeIndex, hostTimeCreationOrder }
        ::= { hostTimeTable 1 }

    HostTimeEntry ::= SEQUENCE {
        hostTimeAddress              OCTET STRING,
        hostTimeCreationOrder        INTEGER (1..65535),
        hostTimeIndex                INTEGER (1..65535),
        hostTimeInPkts               Counter,
        hostTimeOutPkts              Counter,
        hostTimeInOctets             Counter,
        hostTimeOutOctets            Counter,
        hostTimeOutErrors            Counter,
        hostTimeOutBroadcastPkts     Counter,
        hostTimeOutMulticastPkts     Counter
    }

    hostTimeAddress OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION



            "The physical address of this host."
        ::= { hostTimeEntry 1 }

    hostTimeCreationOrder OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry in
            the hostTime table among those entries associated
            with the same hostControlEntry.  This index shall
            be between 1 and N, where N is the value of
            the associated hostControlTableSize.  The ordering
            of the indexes is based on the order of each entry's
            insertion into the table, in which entries added
            earlier have a lower index value than entries added
            later.  Thus the management station has the ability
            to learn of new entries added to this table without
            downloading the entire table.

            It is important to note that the index for a
            particular entry may change as an (earlier) entry
            is deleted from the table.  Because this order may
            change, management stations should make use of the
            hostControlLastDeleteTime variable in the
            hostControlEntry associated with the relevant
            portion of the hostTimeTable.  By observing
            this variable, the management station may detect
            the circumstances where a download of the table
            may have missed entries, and where a previous
            association between a value of hostTimeCreationOrder
            and a hostTimeEntry may no longer hold."
        ::= { hostTimeEntry 2 }

    hostTimeIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The set of collected host statistics of which
            this entry is a part.  The set of hosts
            identified by a particular value of this
            index is associated with the hostControlEntry
            as identified by the same value of hostControlIndex."
        ::= { hostTimeEntry 3 }






    hostTimeInPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets without errors transmitted to
            this address since it was added to the hostTimeTable."
        ::= { hostTimeEntry 4 }

    hostTimeOutPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets including errors transmitted
            by this address since it was added to the
            hostTimeTable."
        ::= { hostTimeEntry 5 }

    hostTimeInOctets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of octets transmitted to this address
            since it was added to the hostTimeTable (excluding
            framing bits but including FCS octets), except for
            those octets in packets that contained errors."
        ::= { hostTimeEntry 6 }

    hostTimeOutOctets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of octets transmitted by this address since
            it was added to the hostTimeTable (excluding framing
            bits but including FCS octets), including those
            octets in packets that contained errors."
        ::= { hostTimeEntry 7 }

    hostTimeOutErrors OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of error packets transmitted by this
            address since this host was added to the



            hostTimeTable."
        ::= { hostTimeEntry 8 }

    hostTimeOutBroadcastPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of good packets transmitted by this
            address that were directed to the broadcast address
            since this host was added to the hostTimeTable."
        ::= { hostTimeEntry 9 }

    hostTimeOutMulticastPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of good packets transmitted by this
            address that were directed to a multicast address
            since this host was added to the hostTimeTable.
            Note that this number does not include packets
            directed to the broadcast address."
        ::= { hostTimeEntry 10 }


    -- The Host Top "N" Group

    -- Implementation of the Host Top N group is optional.
    --
    -- The Host Top N group requires the implementation of the
    -- host group.
    --
    -- The Host Top N group is used to prepare reports that
    -- describe the hosts that top a list ordered by one of
    -- their statistics.  The available statistics are samples
    -- of one of their base statistics, over an interval
    -- specified by the management station.  Thus, these
    -- statistics are rate based.  The management
    -- station also selects how many such hosts are reported.

    -- The hostTopNControlTable is used to initiate the generation
    -- of such a report.  The management station may select the
    -- parameters of such a report, such as which interface,
    -- which statistic, how many hosts, and the start and stop
    -- times of the sampling.  When the report is prepared,
    -- entries are created in the hostTopNTable associated with
    -- the relevant hostTopNControlEntry.  These entries are



    -- static for each report after it has been prepared.

    hostTopNControlTable OBJECT-TYPE
        SYNTAX SEQUENCE OF HostTopNControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of top N host control entries."
        ::= { hostTopN 1 }

    hostTopNControlEntry OBJECT-TYPE
        SYNTAX HostTopNControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A set of parameters that control the creation of a
            report of the top N hosts according to several
            metrics."
        INDEX { hostTopNControlIndex }
        ::= { hostTopNControlTable 1 }

    HostTopNControlEntry ::= SEQUENCE {
        hostTopNControlIndex    INTEGER (1..65535),
        hostTopNHostIndex       INTEGER (1..65535),
        hostTopNRateBase        INTEGER,
        hostTopNTimeRemaining   INTEGER,
        hostTopNDuration        INTEGER,
        hostTopNRequestedSize   INTEGER,
        hostTopNGrantedSize     INTEGER,
        hostTopNStartTime       TimeTicks,
        hostTopNOwner           OwnerString,
        hostTopNStatus          INTEGER
    }

    hostTopNControlIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry
            in the hostTopNControl table.  Each such
            entry defines one top N report prepared for
            one interface."
        ::= { hostTopNControlEntry 1 }

    hostTopNHostIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write



        STATUS mandatory
        DESCRIPTION
            "The host table for which a top N report will be
            prepared on behalf of this entry.  The host table
            identified by a particular value of this index is
            associated with the same host table as identified
            by the same value of hostIndex.

            This object may not be modified if the associated
            hostTopNStatus object is equal to valid(1)."
        ::= { hostTopNControlEntry 2 }

    hostTopNRateBase OBJECT-TYPE
        SYNTAX INTEGER {
                hostTopNInPkts(1),
                hostTopNOutPkts(2),
                hostTopNInOctets(3),
                hostTopNOutOctets(4),
                hostTopNOutErrors(5),
                hostTopNOutBroadcastPkts(6),
                hostTopNOutMulticastPkts(7)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The variable for each host that the hostTopNRate
            variable is based upon.

            This object may not be modified if the associated
            hostTopNStatus object is equal to valid(1)."
        ::= { hostTopNControlEntry 3 }

    hostTopNTimeRemaining OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The number of seconds left in the report currently
            being collected.  When this object is modified by
            the management station, a new collection is started,
            possibly aborting a currently running report.  The
            new value is used as the requested duration of this
            report, which is loaded into the associated
            hostTopNDuration object.

            When this object is set to a non-zero value, any
            associated hostTopNEntries shall be made
            inaccessible by the monitor.  While the value of this



            object is non-zero, it decrements by one per second
            until it reaches zero.  During this time, all
            associated hostTopNEntries shall remain
            inaccessible.  At the time that this object
            decrements to zero, the report is made
            accessible in the hostTopNTable.  Thus, the hostTopN
            table needs to be created only at the end of the
            collection interval."
        DEFVAL { 0 }
        ::= { hostTopNControlEntry 4 }

    hostTopNDuration OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of seconds that this report has collected
            during the last sampling interval, or if this
            report is currently being collected, the number
            of seconds that this report is being collected
            during this sampling interval.

            When the associated hostTopNTimeRemaining object is
            set, this object shall be set by the probe to the
            same value and shall not be modified until the next
            time the hostTopNTimeRemaining is set.

            This value shall be zero if no reports have been
            requested for this hostTopNControlEntry."
        DEFVAL { 0 }
        ::= { hostTopNControlEntry 5 }

    hostTopNRequestedSize OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The maximum number of hosts requested for the top N
            table.

            When this object is created or modified, the probe
            should set hostTopNGrantedSize as closely to this
            object as is possible for the particular probe
            implementation and available resources."
        DEFVAL { 10 }
        ::= { hostTopNControlEntry 6 }





    hostTopNGrantedSize OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The maximum number of hosts in the top N table.

            When the associated hostTopNRequestedSize object is
            created or modified, the probe should set this
            object as closely to the requested value as is
            possible for the particular implementation and
            available resources. The probe must not lower this
            value except as a result of a set to the associated
            hostTopNRequestedSize object.

            Hosts with the highest value of hostTopNRate shall be
            placed in this table in decreasing order of this rate
            until there is no more room or until there are no more
            hosts."
        ::= { hostTopNControlEntry 7 }

    hostTopNStartTime OBJECT-TYPE
        SYNTAX TimeTicks
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The value of sysUpTime when this top N report was
            last started.  In other words, this is the time that
            the associated hostTopNTimeRemaining object was
            modified to start the requested report."
        ::= { hostTopNControlEntry 8 }

    hostTopNOwner OBJECT-TYPE
        SYNTAX OwnerString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is
            therefore using the resources assigned to it."
        ::= { hostTopNControlEntry 9 }

    hostTopNStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The status of this hostTopNControl entry.




            If this object is not equal to valid(1), all
            associated hostTopNEntries shall be deleted by
            the agent."
        ::= { hostTopNControlEntry 10 }

    hostTopNTable OBJECT-TYPE
        SYNTAX SEQUENCE OF HostTopNEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of top N host entries."
        ::= { hostTopN 2 }

    hostTopNEntry OBJECT-TYPE
        SYNTAX HostTopNEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A set of statistics for a host that is part of a
            top N report."
        INDEX { hostTopNReport, hostTopNIndex }
        ::= { hostTopNTable 1 }

    HostTopNEntry ::= SEQUENCE {
        hostTopNReport                INTEGER (1..65535),
        hostTopNIndex                 INTEGER (1..65535),
        hostTopNAddress               OCTET STRING,
        hostTopNRate                  INTEGER
    }

    hostTopNReport OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This object identifies the top N report of which
            this entry is a part.  The set of hosts
            identified by a particular value of this
            object is part of the same report as identified
            by the same value of the hostTopNControlIndex object."
        ::= { hostTopNEntry 1 }

    hostTopNIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry in



            the hostTopN table among those in the same report.
            This index is between 1 and N, where N is the
            number of entries in this table.  Increasing values
            of hostTopNIndex shall be assigned to entries with
            decreasing values of hostTopNRate until index N
            is assigned to the entry with the lowest value of
            hostTopNRate or there are no more hostTopNEntries."
        ::= { hostTopNEntry 2 }

    hostTopNAddress OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The physical address of this host."
        ::= { hostTopNEntry 3 }

    hostTopNRate OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The amount of change in the selected variable
            during this sampling interval.  The selected
            variable is this host's instance of the object
            selected by hostTopNRateBase."
        ::= { hostTopNEntry 4 }


    -- The Matrix Group

    -- Implementation of the Matrix group is optional.
    --
    -- The Matrix group consists of the matrixControlTable,
    -- matrixSDTable and the matrixDSTable.  These tables
    -- store statistics for a particular conversation between
    -- two addresses.  As the device detects a new conversation,
    -- including those to a non-unicast address, it creates a
    -- new entry in both of the matrix tables.
    -- It must only create new entries based on information
    -- received in good packets.  If the monitoring device finds
    -- itself short of resources, it may delete entries as needed.
    -- It is suggested that the device delete the least recently
    -- used entries first.

    matrixControlTable OBJECT-TYPE
        SYNTAX SEQUENCE OF MatrixControlEntry
        ACCESS not-accessible



        STATUS mandatory
        DESCRIPTION
            "A list of information entries for the
            traffic matrix on each interface."
        ::= { matrix 1 }

    matrixControlEntry OBJECT-TYPE
        SYNTAX MatrixControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about a traffic matrix on a
            particular interface."
        INDEX { matrixControlIndex }
        ::= { matrixControlTable 1 }

    MatrixControlEntry ::= SEQUENCE {
        matrixControlIndex           INTEGER (1..65535),
        matrixControlDataSource      OBJECT IDENTIFIER,
        matrixControlTableSize       INTEGER,
        matrixControlLastDeleteTime  TimeTicks,
        matrixControlOwner           OwnerString,
        matrixControlStatus          INTEGER
    }

    matrixControlIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry in the
            matrixControl table.  Each such entry defines
            a function that discovers conversations on a particular
            interface and places statistics about them in the
            matrixSDTable and the matrixDSTable on behalf of this
            matrixControlEntry."
        ::= { matrixControlEntry 1 }

    matrixControlDataSource OBJECT-TYPE
        SYNTAX OBJECT IDENTIFIER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This object identifies the source of
            the data from which this entry creates a traffic matrix.
            This source can be any interface on this device.  In
            order to identify a particular interface, this object
            shall identify the instance of the ifIndex object,



            defined in [4,6], for the desired interface.  For
            example, if an entry were to receive data from
            interface #1, this object would be set to ifIndex.1.

            The statistics in this group reflect all packets
            on the local network segment attached to the
            identified interface.

            This object may not be modified if the associated
            matrixControlStatus object is equal to valid(1)."
        ::= { matrixControlEntry 2 }

    matrixControlTableSize OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of matrixSDEntries in the matrixSDTable
            for this interface.  This must also be the value of
            the number of entries in the matrixDSTable for this
            interface."
        ::= { matrixControlEntry 3 }

    matrixControlLastDeleteTime OBJECT-TYPE
        SYNTAX TimeTicks
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The value of sysUpTime when the last entry
            was deleted from the portion of the matrixSDTable
            or matrixDSTable associated with this
            matrixControlEntry.
            If no deletions have occurred, this value shall be
            zero."
        ::= { matrixControlEntry 4 }

    matrixControlOwner OBJECT-TYPE
        SYNTAX OwnerString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is
            therefore using the resources assigned to it."
        ::= { matrixControlEntry 5 }

    matrixControlStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write



        STATUS mandatory
        DESCRIPTION
            "The status of this matrixControl entry.

            If this object is not equal to valid(1), all
            associated entries in the matrixSDTable and the
            matrixDSTable shall be deleted by the agent."
        ::= { matrixControlEntry 6 }

    matrixSDTable OBJECT-TYPE
        SYNTAX SEQUENCE OF MatrixSDEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of traffic matrix entries indexed by
            source and destination MAC address."
        ::= { matrix 2 }

    matrixSDEntry OBJECT-TYPE
        SYNTAX MatrixSDEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A collection of statistics for communications between
            two addresses on a particular interface."
        INDEX { matrixSDIndex,
                matrixSDSourceAddress, matrixSDDestAddress }
        ::= { matrixSDTable 1 }

    MatrixSDEntry ::= SEQUENCE {
        matrixSDSourceAddress       OCTET STRING,
        matrixSDDestAddress         OCTET STRING,
        matrixSDIndex               INTEGER (1..65535),
        matrixSDPkts                Counter,
        matrixSDOctets              Counter,
        matrixSDErrors              Counter
    }

    matrixSDSourceAddress OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The source physical address."
        ::= { matrixSDEntry 1 }






    matrixSDDestAddress OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The destination physical address."
        ::= { matrixSDEntry 2 }

    matrixSDIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The set of collected matrix statistics of which
            this entry is a part.  The set of matrix statistics
            identified by a particular value of this index
            is associated with the same matrixControlEntry
            as identified by the same value of matrixControlIndex."
        ::= { matrixSDEntry 3 }

    matrixSDPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets transmitted from the source
            address to the destination address (this number
            includes error packets)."
        ::= { matrixSDEntry 4 }

    matrixSDOctets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of octets (excluding framing bits but
            including FCS octets) contained in all packets
            transmitted from the source address to the
            destination address."
        ::= { matrixSDEntry 5 }

    matrixSDErrors OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of error packets transmitted from
            the source address to the destination address."



        ::= { matrixSDEntry 6 }


    -- Traffic matrix tables from destination to source

    matrixDSTable OBJECT-TYPE
        SYNTAX SEQUENCE OF MatrixDSEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of traffic matrix entries indexed by
            destination and source MAC address."
        ::= { matrix 3 }

    matrixDSEntry OBJECT-TYPE
        SYNTAX MatrixDSEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A collection of statistics for communications between
            two address on a particular interface."
        INDEX { matrixDSIndex,
                matrixDSDestAddress, matrixDSSourceAddress }
        ::= { matrixDSTable 1 }

    MatrixDSEntry ::= SEQUENCE {
        matrixDSSourceAddress       OCTET STRING,
        matrixDSDestAddress         OCTET STRING,
        matrixDSIndex               INTEGER (1..65535),
        matrixDSPkts                Counter,
        matrixDSOctets              Counter,
        matrixDSErrors              Counter
    }

    matrixDSSourceAddress OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The source physical address."
        ::= { matrixDSEntry 1 }

    matrixDSDestAddress OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The destination physical address."



        ::= { matrixDSEntry 2 }

    matrixDSIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The set of collected matrix statistics of which
            this entry is a part.  The set of matrix statistics
            identified by a particular value of this index
            is associated with the same matrixControlEntry
            as identified by the same value of matrixControlIndex."
        ::= { matrixDSEntry 3 }

    matrixDSPkts OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets transmitted from the source
            address to the destination address (this number
            includes error packets)."
        ::= { matrixDSEntry 4 }

    matrixDSOctets OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of octets (excluding framing bits
            but including FCS octets) contained in all packets
            transmitted from the source address to the
            destination address."
        ::= { matrixDSEntry 5 }

    matrixDSErrors OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of error packets transmitted from
            the source address to the destination address."
        ::= { matrixDSEntry 6 }


    -- The Filter Group

    -- Implementation of the Filter group is optional.



    --
    -- The Filter group allows packets to be captured with an
    -- arbitrary filter expression.  A logical data and
    -- event stream or "channel" is formed by the packets
    -- that match the filter expression.
    --
    -- This filter mechanism allows the creation of an arbitrary
    -- logical expression with which to filter packets.  Each
    -- filter associated with a channel is OR'ed with the others.
    -- Within a filter, any bits checked in the data and status are
    -- AND'ed with respect to other bits in the same filter.  The
    -- NotMask also allows for checking for inequality.  Finally,
    -- the channelAcceptType object allows for inversion of the
    -- whole equation.
    --
    -- The channel can be turned on or off, and can also
    -- generate events when packets pass through it.

    filterTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FilterEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of packet filter entries."
        ::= { filter 1 }

    filterEntry OBJECT-TYPE
        SYNTAX FilterEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A set of parameters for a packet filter applied on a
            particular interface."
        INDEX { filterIndex }
        ::= { filterTable 1 }

    FilterEntry ::= SEQUENCE {
        filterIndex                 INTEGER (1..65535),
        filterChannelIndex          INTEGER (1..65535),
        filterPktDataOffset         INTEGER,
        filterPktData               OCTET STRING,
        filterPktDataMask           OCTET STRING,
        filterPktDataNotMask        OCTET STRING,
        filterPktStatus             INTEGER,
        filterPktStatusMask         INTEGER,
        filterPktStatusNotMask      INTEGER,
        filterOwner                 OwnerString,
        filterStatus                INTEGER



    }

    filterIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry
            in the filter table.  Each such entry defines
            one filter that is to be applied to every packet
            received on an interface."
        ::= { filterEntry 1 }

    filterChannelIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This object identifies the channel of which this
            filter is a part.  The filters identified by a
            particular value of this object are associated
            with the same channel as identified by the same
            value of the channelIndex object."
        ::= { filterEntry 2 }

    filterPktDataOffset OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The offset from the beginning of each packet where
            a match of packet data will be attempted.  This offset
            is measured from the point in the physical layer
            packet after the framing bits, if any.  For example,
            in an Ethernet frame, this point is at the beginning
            of the destination MAC address.

            This object may not be modified if the associated
            filterStatus object is equal to valid(1)."
        DEFVAL { 0 }
        ::= { filterEntry 3 }

    filterPktData OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The data that is to be matched with the input packet.



            For each packet received, this filter and the
            accompanying filterPktDataMask and
            filterPktDataNotMask will be adjusted for the
            offset.  The only bits relevant to this
            match algorithm are those that have the corresponding
            filterPktDataMask bit equal to one.  The following
            three rules are then applied to every packet:

            (1) If the packet is too short and does not have data
                corresponding to part of the filterPktData, the
                packet will fail this data match.

            (2) For each relevant bit from the packet with the
                corresponding filterPktDataNotMask bit set to
                zero, if the bit from the packet is not equal to
                the corresponding bit from the filterPktData,
                then the packet will fail this data match.

            (3) If for every relevant bit from the packet with the
                corresponding filterPktDataNotMask bit set to one,
                the bit from the packet is equal to the
                corresponding bit from the filterPktData, then
                the packet will fail this data match.

            Any packets that have not failed any of the three
            matches above have passed this data match.

            This object may not be modified if the associated
            filterStatus object is equal to valid(1)."
        ::= { filterEntry 4 }

    filterPktDataMask OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The mask that is applied to the match process.
            After adjusting this mask for the offset, only those
            bits in the received packet that correspond to bits
            set in this mask are relevant for further processing
            by the match algorithm.  The offset is applied to
            filterPktDataMask in the same way it is applied to
            the filter.  For the purposes of the matching
            algorithm, if the associated filterPktData object
            is longer than this mask, this mask is conceptually
            extended with '1' bits until it reaches the
            length of the filterPktData object.




            This object may not be modified if the associated
            filterStatus object is equal to valid(1)."
        ::= { filterEntry 5 }

    filterPktDataNotMask OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The inversion mask that is applied to the match
            process.  After adjusting this mask for the offset,
            those relevant bits in the received packet that
            correspond to bits cleared in this mask must all
            be equal to their corresponding bits in the
            filterPktData object for the packet to be accepted.
            In addition, at least one of those relevant
            bits in the received packet that correspond to bits
            set in this mask must be different to its
            corresponding bit in the filterPktData object.

            For the purposes of the matching algorithm, if
            the associated filterPktData object is longer than
            this mask, this mask is conceptually extended with
            '0' bits until it reaches the length of the
            filterPktData object.

            This object may not be modified if the associated
            filterStatus object is equal to valid(1)."
        ::= { filterEntry 6 }

    filterPktStatus OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The status that is to be matched with the input
            packet.  The only bits relevant to this match
            algorithm are those that have the corresponding
            filterPktStatusMask bit equal to one.

            The following two rules are then applied to every
            packet:

            (1) For each relevant bit from the packet status
                with the corresponding filterPktStatusNotMask
                bit set to zero, if the bit from the packet
                status is not equal to the corresponding bit
                from the filterPktStatus, then the packet will



                fail this status match.

            (2) If for every relevant bit from the packet status
                with the corresponding filterPktStatusNotMask
                bit set to one, the bit from the packet status
                is equal to the corresponding bit from the
                filterPktStatus, then the packet will fail
                this status match.

            Any packets that have not failed either of the two
            matches above have passed this status match.

            The value of the packet status is a sum.  This sum
            initially takes the value zero.  Then, for each
            error, E, that has been discovered in this packet,
            2 raised to a value representing E is added to the sum.
            The errors and the bits that represent them are
            dependent on the media type of the interface that
            this channel is receiving packets from.

            The errors defined for a packet captured off of an
            Ethernet interface are as follows:

                bit #    Error
                    0    Packet is longer than 1518 octets
                    1    Packet is shorter than 64 octets
                    2    Packet experienced a CRC or Alignment
                         error

            For example, an Ethernet fragment would have a
            value of 6 (2^1 + 2^2).

            As this MIB is expanded to new media types, this
            object will have other media-specific errors defined.

            For the purposes of this status matching algorithm, if
            the packet status is longer than this
            object, filterPktStatus this object is conceptually
            extended with '0' bits until it reaches the size of
            the packet status.

            This object may not be modified if the associated
            filterStatus object is equal to valid(1)."
        ::= { filterEntry 7 }

    filterPktStatusMask OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write



        STATUS mandatory
        DESCRIPTION
            "The mask that is applied to the status match process.
            Only those bits in the received packet that correspond
            to bits set in this mask are relevant for further
            processing by the status match algorithm.  For the
            purposes of the matching algorithm, if the
            associated filterPktStatus object is longer than
            this mask, this mask is conceptually extended with
            '1' bits until it reaches the size of the
            filterPktStatus.  In addition, if a packet status is
            longer than this mask, this mask is conceptually
            extended with '0' bits until it reaches the size of
            the packet status.

            This object may not be modified if the associated
            filterStatus object is equal to valid(1)."
        ::= { filterEntry 8 }

    filterPktStatusNotMask OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The inversion mask that is applied to the status match
            process.  Those relevant bits in the received packet
            status that correspond to bits cleared in this mask
            must all be equal to their corresponding bits in the
            filterPktStatus object for the packet to be accepted.
            In addition, at least one of those relevant bits in the
            received packet status that correspond to bits set in
            this mask must be different to its corresponding bit
            in the filterPktStatus object for the packet to be
            accepted.

            For the purposes of the matching algorithm, if the
            associated filterPktStatus object or a packet status
            is longer than this mask, this mask is conceptually
            extended with '0' bits until it reaches the longer of
            the lengths of the filterPktStatus object and the
            packet status.

            This object may not be modified if the associated
            filterStatus object is equal to valid(1)."
        ::= { filterEntry 9 }

    filterOwner OBJECT-TYPE
        SYNTAX OwnerString



        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is
            therefore using the resources assigned to it."
        ::= { filterEntry 10 }

    filterStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The status of this filter entry."
        ::= { filterEntry 11 }

    channelTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ChannelEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of packet channel entries."
        ::= { filter 2 }

    channelEntry OBJECT-TYPE
        SYNTAX ChannelEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A set of parameters for a packet channel applied on a
            particular interface."
        INDEX { channelIndex }
        ::= { channelTable 1 }

    ChannelEntry ::= SEQUENCE {
        channelIndex                 INTEGER (1..65535),
        channelIfIndex               INTEGER (1..65535),
        channelAcceptType            INTEGER,
        channelDataControl           INTEGER,
        channelTurnOnEventIndex      INTEGER (0..65535),
        channelTurnOffEventIndex     INTEGER (0..65535),
        channelEventIndex            INTEGER (0..65535),
        channelEventStatus           INTEGER,
        channelMatches               Counter,
        channelDescription           DisplayString (SIZE (0..127)),
        channelOwner                 OwnerString,
        channelStatus                INTEGER
    }




    channelIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry
            in the channel table.  Each such
            entry defines one channel, a logical data
            and event stream."
        ::= { channelEntry 1 }

    channelIfIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The value of this object uniquely identifies the
            interface on this remote network monitoring device
            to which the associated filters are applied to allow
            data into this channel.  The interface identified by
            a particular value of this object is the same
            interface as identified by the same value of the
            ifIndex object, defined in [4,6].  The filters in
            this group are applied to all packets on the local
            network segment attached to the identified
            interface.

            This object may not be modified if the associated
            channelStatus object is equal to valid(1)."
        ::= { channelEntry 2 }

    channelAcceptType OBJECT-TYPE
        SYNTAX INTEGER {
            acceptMatched(1),
            acceptFailed(2)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This object controls the action of the filters
            associated with this channel.  If this object is equal
            to acceptMatched(1), packets will be accepted to this
            channel if they are accepted by both the packet data
            and packet status matches of an associated filter. If
            this object is equal to acceptFailed(2), packets will
            be accepted to this channel only if they fail either
            the packet data match or the packet status match of
            each of the associated filters.



            This object may not be modified if the associated
            channelStatus object is equal to valid(1)."
        ::= { channelEntry 3 }

    channelDataControl OBJECT-TYPE
        SYNTAX INTEGER {
            on(1),
            off(2)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This object controls the flow of data through this
            channel.  If this object is on(1), data, status and
            events flow through this channel.  If this object is
            off(2), data, status and events will not flow through
            this channel."
        DEFVAL { off }
        ::= { channelEntry 4 }

    channelTurnOnEventIndex OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The value of this object identifies the event
            that is configured to turn the associated
            channelDataControl from off to on when the event is
            generated.  The event identified by a particular value
            of this object is the same event as identified by the
            same value of the eventIndex object.  If there is no
            corresponding entry in the eventTable, then no
            association exists.  In fact, if no event is intended
            for this channel, channelTurnOnEventIndex must be
            set to zero, a non-existent event index.

            This object may not be modified if the associated
            channelStatus object is equal to valid(1)."
        ::= { channelEntry 5 }

    channelTurnOffEventIndex OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The value of this object identifies the event
            that is configured to turn the associated
            channelDataControl from on to off when the event is



            generated.  The event identified by a particular value
            of this object is the same event as identified by the
            same value of the eventIndex object.  If there is no
            corresponding entry in the eventTable, then no
            association exists.  In fact, if no event is intended
            for this channel, channelTurnOffEventIndex must be
            set to zero, a non-existent event index.

            This object may not be modified if the associated
            channelStatus object is equal to valid(1)."
        ::= { channelEntry 6 }

    channelEventIndex OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The value of this object identifies the event
            that is configured to be generated when the
            associated channelDataControl is on and a packet
            is matched.  The event identified by a particular value
            of this object is the same event as identified by the
            same value of the eventIndex object.  If there is no
            corresponding entry in the eventTable, then no
            association exists.  In fact, if no event is intended
            for this channel, channelEventIndex must be
            set to zero, a non-existent event index.

            This object may not be modified if the associated
            channelStatus object is equal to valid(1)."
        ::= { channelEntry 7 }

    channelEventStatus OBJECT-TYPE
        SYNTAX INTEGER {
            eventReady(1),
            eventFired(2),
            eventAlwaysReady(3)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The event status of this channel.

            If this channel is configured to generate events
            when packets are matched, a means of controlling
            the flow of those events is often needed.  When
            this object is equal to eventReady(1), a single
            event may be generated, after which this object



            will be set by the probe to eventFired(2).  While
            in the eventFired(2) state, no events will be
            generated until the object is modified to
            eventReady(1) (or eventAlwaysReady(3)).  The
            management station can thus easily respond to a
            notification of an event by re-enabling this object.

            If the management station wishes to disable this
            flow control and allow events to be generated
            at will, this object may be set to
            eventAlwaysReady(3).  Disabling the flow control
            is discouraged as it can result in high network
            traffic or other performance problems."
        DEFVAL { eventReady }
        ::= { channelEntry 8 }

    channelMatches OBJECT-TYPE
        SYNTAX Counter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of times this channel has matched a packet.
            Note that this object is updated even when
            channelDataControl is set to off."
        ::= { channelEntry 9 }

    channelDescription OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..127))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "A comment describing this channel."
        ::= { channelEntry 10 }

    channelOwner OBJECT-TYPE
        SYNTAX OwnerString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is therefore
            using the resources assigned to it."
        ::= { channelEntry 11 }

    channelStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION



            "The status of this channel entry."
        ::= { channelEntry 12 }


    -- The Packet Capture Group

    -- Implementation of the Packet Capture group is optional.
    --
    -- The Packet Capture Group requires implementation of the
    -- Filter Group.
    --
    -- The Packet Capture group allows packets to be captured
    -- upon a filter match.  The bufferControlTable controls
    -- the captured packets output from a channel that is
    -- associated with it.  The captured packets are placed
    -- in entries in the captureBufferTable.  These entries are
    -- associated with the bufferControlEntry on whose behalf they
    -- were stored.

    bufferControlTable OBJECT-TYPE
        SYNTAX SEQUENCE OF BufferControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of buffers control entries."
        ::= { capture 1 }

    bufferControlEntry OBJECT-TYPE
        SYNTAX BufferControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A set of parameters that control the collection of
            a stream of packets that have matched filters."
        INDEX { bufferControlIndex }
        ::= { bufferControlTable 1 }

    BufferControlEntry ::= SEQUENCE {
        bufferControlIndex                INTEGER (1..65535),
        bufferControlChannelIndex         INTEGER (1..65535),
        bufferControlFullStatus           INTEGER,
        bufferControlFullAction           INTEGER,
        bufferControlCaptureSliceSize     INTEGER,
        bufferControlDownloadSliceSize    INTEGER,
        bufferControlDownloadOffset       INTEGER,
        bufferControlMaxOctetsRequested   INTEGER,
        bufferControlMaxOctetsGranted     INTEGER,
        bufferControlCapturedPackets      INTEGER,



        bufferControlTurnOnTime           TimeTicks,
        bufferControlOwner                OwnerString,
        bufferControlStatus               INTEGER
    }

    bufferControlIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry
            in the bufferControl table.  The value of this
            index shall never be zero.  Each such
            entry defines one set of packets that is
            captured and controlled by one or more filters."
        ::= { bufferControlEntry 1 }

    bufferControlChannelIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "An index that identifies the channel that is the
            source of packets for this bufferControl table.
            The channel identified by a particular value of this
            index is the same as identified by the same value of
            the channelIndex object.

            This object may not be modified if the associated
            bufferControlStatus object is equal to valid(1)."
        ::= { bufferControlEntry 2 }

    bufferControlFullStatus OBJECT-TYPE
        SYNTAX INTEGER {
                spaceAvailable(1),
                full(2)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This object shows whether the buffer has room to
            accept new packets or if it is full.

            If the status is spaceAvailable(1), the buffer is
            accepting new packets normally.  If the status is
            full(2) and the associated bufferControlFullAction
            object is wrapWhenFull, the buffer is accepting new
            packets by deleting enough of the oldest packets



            to make room for new ones as they arrive.  Otherwise,
            if the status is full(2) and the
            bufferControlFullAction object is lockWhenFull,
            then the buffer has stopped collecting packets.

            When this object is set to full(2) the probe must
            not later set it to spaceAvailable(1) except in the
            case of a significant gain in resources such as
            an increase of bufferControlOctetsGranted.  In
            particular, the wrap-mode action of deleting old
            packets to make room for newly arrived packets
            must not affect the value of this object."
        ::= { bufferControlEntry 3 }

    bufferControlFullAction OBJECT-TYPE
        SYNTAX INTEGER {
                lockWhenFull(1),
                wrapWhenFull(2)    -- FIFO
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "Controls the action of the buffer when it
            reaches the full status.  When in the lockWhenFull(1)
            state a packet is added to the buffer that
            fills the buffer, the bufferControlFullStatus will
            be set to full(2) and this buffer will stop capturing
            packets."
        ::= { bufferControlEntry 4 }

    bufferControlCaptureSliceSize OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The maximum number of octets of each packet
            that will be saved in this capture buffer.
            For example, if a 1500 octet packet is received by
            the probe and this object is set to 500, then only
            500 octets of the packet will be stored in the
            associated capture buffer.  If this variable is set
            to 0, the capture buffer will save as many octets
            as is possible.

            This object may not be modified if the associated
            bufferControlStatus object is equal to valid(1)."
        DEFVAL { 100 }
        ::= { bufferControlEntry 5 }



    bufferControlDownloadSliceSize OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The maximum number of octets of each packet
            in this capture buffer that will be returned in
            an SNMP retrieval of that packet.  For example,
            if 500 octets of a packet have been stored in the
            associated capture buffer, the associated
            bufferControlDownloadOffset is 0, and this
            object is set to 100, then the captureBufferPacket
            object that contains the packet will contain only
            the first 100 octets of the packet.

            A prudent manager will take into account possible
            interoperability or fragmentation problems that may
            occur if the download slice size is set too large.
            In particular, conformant SNMP implementations are not
            required to accept messages whose length exceeds 484
            octets, although they are encouraged to support larger
            datagrams whenever feasible."
        DEFVAL { 100 }
        ::= { bufferControlEntry 6 }

    bufferControlDownloadOffset OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The offset of the first octet of each packet
            in this capture buffer that will be returned in
            an SNMP retrieval of that packet.  For example,
            if 500 octets of a packet have been stored in the
            associated capture buffer and this object is set to
            100, then the captureBufferPacket object that
            contains the packet will contain bytes starting
            100 octets into the packet."
        DEFVAL { 0 }
        ::= { bufferControlEntry 7 }

    bufferControlMaxOctetsRequested OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The requested maximum number of octets to be
            saved in this captureBuffer, including any



            implementation-specific overhead. If this variable
            is set to -1, the capture buffer will save as many
            octets as is possible.

            When this object is created or modified, the probe
            should set bufferControlMaxOctetsGranted as closely
            to this object as is possible for the particular probe
            implementation and available resources.  However, if
            the object has the special value of -1, the probe
            must set bufferControlMaxOctetsGranted to -1."
        DEFVAL { -1 }
        ::= { bufferControlEntry 8 }

    bufferControlMaxOctetsGranted OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The maximum number of octets that can be
            saved in this captureBuffer, including overhead.
            If this variable is -1, the capture buffer will save
            as many octets as possible.

            When the bufferControlMaxOctetsRequested object is
            created or modified, the probe should set this object
            as closely to the requested value as is possible for
            the particular probe implementation and available
            resources.  However, if the request object has the
            special value of -1, the probe must set this object
            to -1.  The probe must not lower this value except
            as a result of a modification to the associated
            bufferControlMaxOctetsRequested object.

            When this maximum number of octets is reached
            and a new packet is to be added to this
            capture buffer and the corresponding
            bufferControlFullAction is set to wrapWhenFull(2),
            enough of the oldest packets associated with this
            capture buffer shall be deleted by the agent so
            that the new packet can be added.  If the
            corresponding bufferControlFullAction is set to
            lockWhenFull(1), the new packet shall be discarded.
            In either case, the probe must set
            bufferControlFullStatus to full(2).

            When the value of this object changes to a value less
            than the current value, entries are deleted from
            the captureBufferTable associated with this



            bufferControlEntry.  Enough of the
            oldest of these captureBufferEntries shall be
            deleted by the agent so that the number of octets
            used remains less than or equal to the new value of
            this object.

            When the value of this object changes to a value greater
            than the current value, the number of associated
            captureBufferEntries may be allowed to grow."
        ::= { bufferControlEntry 9 }

    bufferControlCapturedPackets OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of packets currently in this captureBuffer."
        ::= { bufferControlEntry 10 }

    bufferControlTurnOnTime OBJECT-TYPE
        SYNTAX TimeTicks
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The value of sysUpTime when this capture buffer was
            first turned on."
        ::= { bufferControlEntry 11 }

    bufferControlOwner OBJECT-TYPE
        SYNTAX OwnerString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is therefore
            using the resources assigned to it."
        ::= { bufferControlEntry 12 }

    bufferControlStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The status of this buffer Control Entry."
        ::= { bufferControlEntry 13 }

    captureBufferTable OBJECT-TYPE
        SYNTAX SEQUENCE OF CaptureBufferEntry
        ACCESS not-accessible



        STATUS mandatory
        DESCRIPTION
            "A list of packets captured off of a channel."
        ::= { capture 2 }

    captureBufferEntry OBJECT-TYPE
        SYNTAX CaptureBufferEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A packet captured off of an attached network."
        INDEX { captureBufferControlIndex, captureBufferIndex }
        ::= { captureBufferTable 1 }

    CaptureBufferEntry ::= SEQUENCE {
        captureBufferControlIndex   INTEGER (1..65535),
        captureBufferIndex          INTEGER,
        captureBufferPacketID       INTEGER,
        captureBufferPacketData     OCTET STRING,
        captureBufferPacketLength   INTEGER,
        captureBufferPacketTime     INTEGER,
        captureBufferPacketStatus   INTEGER
    }

    captureBufferControlIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The index of the bufferControlEntry with which
            this packet is associated."
        ::= { captureBufferEntry 1 }

    captureBufferIndex OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry
            in the captureBuffer table associated with a
            particular bufferControlEntry.  This index will
            start at 1 and increase by one for each new packet
            added with the same captureBufferControlIndex."
        ::= { captureBufferEntry 2 }

    captureBufferPacketID OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only



        STATUS mandatory
        DESCRIPTION
            "An index that describes the order of packets
            that are received on a particular interface.
            The packetID of a packet captured on an
            interface is defined to be greater than the
            packetID's of all packets captured previously on
            the same interface.  As the captureBufferPacketID
            object has a maximum positive value of 2^31 - 1,
            any captureBufferPacketID object shall have the
            value of the associated packet's packetID mod 2^31."
        ::= { captureBufferEntry 3 }

    captureBufferPacketData OBJECT-TYPE
        SYNTAX OCTET STRING
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The data inside the packet, starting at the beginning
            of the packet plus any offset specified in the
            associated bufferControlDownloadOffset, including any
            link level headers.  The length of the data in this
            object is the minimum of the length of the captured
            packet minus the offset, the length of the associated
            bufferControlCaptureSliceSize minus the offset, and the
            associated bufferControlDownloadSliceSize.  If this
            minimum is less than zero, this object shall have a
            length of zero."
        ::= { captureBufferEntry 4 }

    captureBufferPacketLength OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The actual length (off the wire) of the packet stored
            in this entry, including FCS octets."
        ::= { captureBufferEntry 5 }

    captureBufferPacketTime OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of milliseconds that had passed since
            this capture buffer was first turned on when this
            packet was captured."
        ::= { captureBufferEntry 6 }



    captureBufferPacketStatus OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "A value which indicates the error status of this
            packet.

            The value of this object is defined in the same way as
            filterPacketStatus.  The value is a sum.  This sum
            initially takes the value zero.  Then, for each
            error, E, that has been discovered in this packet,
            2 raised to a value representing E is added to the sum.

            The errors defined for a packet captured off of an
            Ethernet interface are as follows:

                bit #    Error
                    0    Packet is longer than 1518 octets
                    1    Packet is shorter than 64 octets
                    2    Packet experienced a CRC or Alignment
                         error
                    3    First packet in this capture buffer after
                         it was detected that some packets were
                         not processed correctly.

            For example, an Ethernet fragment would have a
            value of 6 (2^1 + 2^2).

            As this MIB is expanded to new media types, this object
            will have other media-specific errors defined."
        ::= { captureBufferEntry 7 }


    -- The Event Group

    -- Implementation of the Event group is optional.
    --
    -- The Event group controls the generation and notification
    -- of events from this device.  Each entry in the eventTable
    -- describes the parameters of the event that can be triggered.
    -- Each event entry is fired by an associated condition located
    -- elsewhere in the MIB.  An event entry may also be associated
    -- with a function elsewhere in the MIB that will be executed
    -- when the event is generated.  For example, a channel may
    -- be turned on or off by the firing of an event.
    --
    -- Each eventEntry may optionally specify that a log entry



    -- be created on its behalf whenever the event occurs.
    -- Each entry may also specify that notification should
    -- occur by way of SNMP trap messages.  In this case, the
    -- community for the trap message is given in the associated
    -- eventCommunity object.  The enterprise and specific trap
    -- fields of the trap are determined by the condition that
    -- triggered the event.  Three traps are defined in a companion
    -- document: risingAlarm, fallingAlarm, and packetMatch.
    -- If the eventTable is triggered by a condition specified
    -- elsewhere, the enterprise and specific trap fields
    -- must be specified for traps generated for that condition.

    eventTable OBJECT-TYPE
        SYNTAX SEQUENCE OF EventEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of events to be generated."
        ::= { event 1 }

    eventEntry OBJECT-TYPE
        SYNTAX EventEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A set of parameters that describe an event to be
            generated when certain conditions are met."
        INDEX { eventIndex }
        ::= { eventTable 1 }

    EventEntry ::= SEQUENCE {
        eventIndex          INTEGER (1..65535),
        eventDescription    DisplayString (SIZE (0..127)),
        eventType           INTEGER,
        eventCommunity      OCTET STRING (SIZE (0..127)),
        eventLastTimeSent   TimeTicks,
        eventOwner          OwnerString,
        eventStatus         INTEGER
    }

    eventIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry in the
            event table.  Each such entry defines one event that
            is to be generated when the appropriate conditions



            occur."
        ::= { eventEntry 1 }

    eventDescription OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..127))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "A comment describing this event entry."
        ::= { eventEntry 2 }

    eventType OBJECT-TYPE
        SYNTAX INTEGER {
                none(1),
                log(2),
                snmp-trap(3),    -- send an SNMP trap
                log-and-trap(4)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The type of notification that the probe will make
            about this event.  In the case of log, an entry is
            made in the log table for each event.  In the case of
            snmp-trap, an SNMP trap is sent to one or more
            management stations."
        ::= { eventEntry 3 }

    eventCommunity OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE (0..127))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "If an SNMP trap is to be sent, it will be sent to
            the SNMP community specified by this octet string.
            In the future this table will be extended to include
            the party security mechanism.  This object shall be
            set to a string of length zero if it is intended that
            that mechanism be used to specify the destination of
            the trap."
        ::= { eventEntry 4 }

    eventLastTimeSent OBJECT-TYPE
        SYNTAX TimeTicks
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The value of sysUpTime at the time this event



            entry last generated an event.  If this entry has
            not generated any events, this value will be
            zero."
        ::= { eventEntry 5 }

    eventOwner OBJECT-TYPE
        SYNTAX OwnerString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The entity that configured this entry and is therefore
            using the resources assigned to it.

            If this object contains a string starting with 'monitor'
            and has associated entries in the log table, all
            connected management stations should retrieve those
            log entries, as they may have significance to all
            management stations connected to this device"
        ::= { eventEntry 6 }

    eventStatus OBJECT-TYPE
        SYNTAX EntryStatus
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The status of this event entry.

            If this object is not equal to valid(1), all associated
            log entries shall be deleted by the agent."
        ::= { eventEntry 7 }

    --
    logTable OBJECT-TYPE
        SYNTAX SEQUENCE OF LogEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of events that have been logged."
        ::= { event 2 }

    logEntry OBJECT-TYPE
        SYNTAX LogEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A set of data describing an event that has been
            logged."
        INDEX { logEventIndex, logIndex }



        ::= { logTable 1 }

    LogEntry ::= SEQUENCE {
        logEventIndex           INTEGER (1..65535),
        logIndex                INTEGER,
        logTime                 TimeTicks,
        logDescription          DisplayString (SIZE (0..255))
    }

    logEventIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The event entry that generated this log
            entry.  The log identified by a particular
            value of this index is associated with the same
            eventEntry as identified by the same value
            of eventIndex."
        ::= { logEntry 1 }

    logIndex OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An index that uniquely identifies an entry
            in the log table amongst those generated by the
            same eventEntries.  These indexes are
            assigned beginning with 1 and increase by one
            with each new log entry.  The association
            between values of logIndex and logEntries
            is fixed for the lifetime of each logEntry.
            The agent may choose to delete the oldest
            instances of logEntry as required because of
            lack of memory.  It is an implementation-specific
            matter as to when this deletion may occur."
        ::= { logEntry 2 }

    logTime OBJECT-TYPE
        SYNTAX TimeTicks
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The value of sysUpTime when this log entry was
            created."
        ::= { logEntry 3 }




    logDescription OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..255))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "An implementation dependent description of the
            event that activated this log entry."
        ::= { logEntry 4 }

    END