Other Control Messages
Before a SIMP or a host voluntarily disables a SIMP-host link, it should send at least one Link Going Down control message over that link. The format of such a message is illustrated in Figure 30. HAP does not define the action(s) that should be taken by a SIMP or a host when such a message is received; informing the Network Operations Center (NOC) and/or the network users of the impending event is a typical course of action. Note that each Link Going Down message only pertains to the SIMP-host link that it is sent over; if a host and a SIMP are connected by multiple links, these links may be selectively disabled.
A No Operation (NOP) control message may be sent at any time by a SIMP or a host. The format of such a message is illustrated in Figure 31. A NOP message contains up to 32 words of arbitrary data which are undefined by HAP. NOP messages may be required in some cases to clear the state of the SIMP-host link hardware.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
0 | 1|LB|GOPRI| XXXXX | REASON | 7 |
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
1 | HEADER CHECKSUM |
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
2 | TIME UNTIL DOWN |
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
3 | DOWN DURATION |
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
Figure 30 . LINK GOING DOWN
0[15] Message Type = 1 (Control Message).
0[14] Loopback Bit.
0[12-13] Go-Priority.
0[8-11] Reserved.
0[4-7] Reason. This field is used by the SIMP or the host to indicate the reason for disabling this SIMP-host link as follows:
- 0 = NOT going down: Cancel previous Link Going Down message
- 1 = Unspecified reason
- 2 = Scheduled PM
- 3 = Scheduled hardware work
- 4 = Scheduled software work
- 5 = Emergency restart
- 6 = Power outage
- 7 = Software breakpoint
- 8 = Hardware failure
- 9 = Not scheduled up
- 10 = Last warning: The SIMP or host is disabling the link in 10 seconds
- 11-15 = Undefined
0[0-3] Control Message Type = 7 (Link Going Down).
1[0-15] Header Checksum. Covers words 0-3.
2[0-15] Time Until Down. This field specifies the amount of time remaining until the SIMP or host disables the link (in minutes). An entry of zero indicates that there is less than a minute remaining.
3[0-15] Down Duration. This field specifies the amount of time that the SIMP-host link will be down (in minutes). An entry of zero indicates that the down duration will be less than a minute. An entry of -1 (all bits set) indicates an indefinite down duration.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
0 | 1|LB| XXXXX | 6 |
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
1 | HEADER CHECKSUM |
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
2-N | ARBITRARY DATA |
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
Figure 31 . NO OPERATION (NOP)
0[15] Message Type = 1 (Control Message).
0[14] Loopback Bit.
0[4-13] Reserved.
0[0-3] Control Message Type = 6 (NOP).
1[0-15] Header Checksum. Covers words 0-N.
2-N Arbitrary Data. Up to 32 words of data may be sent. The data are undefined by HAP.