8.11-9. Reject, TPDU Error and Conformance
8.11 Reject (RJ)
(Not used in Classes 0, 2, and 4)
8.11.1 Structure
Normal Format
1 2 3 4 EOT 5 6 p
LI RJ CDT DST-REFERENCE . YR-TU-NR Variable Part
0101 0.
Extended Format
1 2 3 4 EOT 5,6,7,8 9,10 11 p
LI RJ DST-REFERENCE . YR-TU-NR CDT Variable
0l0l0000 Part
8.11.2 LI
See Section 8.2.1
8.11.3 Fixed Part
(Octets 2 to 5, normal format; 2 to 10, extended format)
RJ: Reject Command Code: 0101
CDT: Credit Value (set to 0 in class 1)
DST-REFERENCE: Same as Section 8.4.3
YR-TU-NR: Sequence number indicating the next expected
TPDU from which retransmission should occur.
8.11.4 Variable Part
No parameters exclusive to this TPDU type.
8.12 TPDU Error (ERR)
1 2 3 4 5 6
LI ERR DST-REFERENCE Reject Parameters
01110000 Cause
8.12.1 LI
See Section 8.2.1
8.12.2 Fixed Part
ERR: TPDU Error Code: 0111
DST-REFERENCE: Same as Section 8.4.3
REJECT CAUSE:
00000000 Reason not specified
00000001 Invalid parameter code
00000010 Invalid TPDU type
00000011 Invalid parameter value
8.12.3 Variable Part (Octets 6 to the end)
Parameter Code: 1100001
Parameter Value Field:
Contains the bit pattern of the rejected TPDU up to and including the octet which caused the rejection. This parameter is mandatory in Class 0.
Checksum (See Section 8.2.3.1)
SECTION THREE - CONFORMANCE
9. CONFORMANCE
Implementations claiming conformance to this standard shall:
-
Implement either Class 0 or Class 2 or both.
-
If other classes are implemented, the following rules shall be observed:
a) If Class 3 or Class 4 is implemented then Class 2 must be implemented
b) If Class 1 is implemented then Class 0 must be implemented.
-
The following table defines the requirements for the implementation of the options defined in previous sections:
Class
0 1 2 3 4
TPDU with Checksum no no no no m
TPDU without Checksum m m m m o
Expedited Data Transfer no m m m m
No Expedited Data Transfer m m m m m
Flow Control in Class 2 no no m no no
No Flow Control in Class 2 no no o no no
7 bits format (normal) m m m m m
31 bits format (extended) no no o o o
Use of Receipt Confirmation in no o no no no
Class 1
No use of Receipt Confirmation in no m no no no
Class 1
Use of Network Expedited in Class no o no no no
1, if T-EXPEDITED DATA necessary
No use of Network Expedited in no m no no no
Class 1, if T-EXPEDITED DATA necessary
o - optional: An implementation may or may not
provide this user-selected option.
m - mandatory: An implementation must provide for this
option
no - An implementation shall not provide
this option.
-
Implementations claiming conformance shall support a TPDU length of 128 octets. If larger maximum TPDU sizes can be supported in Classes 1,2,3, or 4, then all permitted TPDU sizes between the maximum and 128 octets shall be supported.
-
Claims of conformance shall state:
a) which class of protocol is supported.
b) which additional options indicated by the letter 'o' in the above table are supported.