D. Checking
The nature of remote job entry service is such that a low rate of undetected errors is mandatory. The IMP's use CRC's and sequence numbers over the communication lines, so the effective IMP-IMP error rate should be negligible. Although there is no checking provided for the IMP-Host interface, it seems likely that these interfaces will either be reliable or fail catastrophically; it seems unlikely that "drop-outs" or other random failures will occur. Therefore only the following simple checks are provided:
-
Each block will (at least initially) contain a fixed bit check pattern using both on and off states of each bit path in the 16 bit PDA interface at CCN.
It is anticipated that even this crude check on IMP-Host transmission will be useful both during the initial checkout of hardware and software and also later if the interface becomes marginal. However, either site can omit the check pattern if it sets a bit in the Block Control Byte (BCBYTE); see Section F.
-
Each block contains a sequence number. Again this is intended for initial checkout and to signal catastrophic hardware or software problems. If the receiver detects an incorrect check pattern or block sequence number, he aborts the channel by closing the corresponding network connection; the remote site should then issue an RFC to re-establish the network connection. The sequence number of the first block after an RFC is 0. The numbers are never reset while the connection is open.