Appendixes C - G: Summaries
Appendix C. Data Element Identifier Octets
Identifier Identifier Data Element Name
00 000 No-Op
01 001 End-of-Constructor
02 002 ASCII-String
08 010 Boolean
09 011 Unique-ID
0A 012 Sequence
0B 013 Set
20 040 Integer
21 041 Padding
24 044 Property-List
28 050 Date
43 103 Bit-String
45 105 Property
46 106 Compressed
47 107 Encrypted
4C 114 Field
4D 115 Message
7E 176 Extension
7F 177 Vendor-Defined
Appendix D. Summary of Message Fields by Compliance Category
This appendix is for reference use. It contains no new information, but rather abstracts from that presented in Section 3.1.
This appendix contains the message field names arranged alphabetically within compliance category. (Appendix E orders the field names within functional category.) Complete field definitions appear in Appendix A.
Required fields must appear in a message. Basic fields must be recognized and processed by all CBM systems. Optional fields need not be supported by a CBMS but, if supported, must be processed according to the meanings defined by the message format specification.
D.1 REQUIRED Fields
From
Posted-Date
To
D.2 BASIC Fields
Cc
Reply-To
Subject
Text
D.3 OPTIONAL Fields
Attachments
Author
Bcc
Circulate-Next
Circulate-To
Comments
Date
End-Date
In-Reply-To
Keywords
Message-Class
Message-ID
Obsoletes
Originator-Serial-Number
Precedence
Received-Date
Received-From
References
Reissue-Type
Sender
Start-Date
Warning-Date
Appendix E. Summary of Message Semantics by Function
This appendix is for reference use. It contains no new information, but rather abstracts from that presented in Section 3.1.
This appendix contains the message field names arranged alphabetically within functional class. (Appen orders the field names within compliance class.) Complete field definitions appear in Appendix A.
E.1 Circulation
Circulate-Next
Circulate-To
E.2 Cross Referencing
In-Reply-To
Message-ID
Obsoletes
Originator-Serial-Number
References
E.3 Life spans
End-Date
Start-Date
Warning-Date
E.4 Delivery System
Received-Date
Received-From
E.5 Miscellaneous Fields Used Generally
Attachments
Comments
Keywords
Message-Class
Precedence
Subject
Text
E.6 Reply Generation
Reply-To
E.7 Reissuing
Reissue-Type
E.8 Sending (Normal Transmission)
Author
Bcc
Cc
Date
From
Posted-Date
Sender
To
Appendix F. Summary of Data Element Syntax
This appendix summarizes data element syntax by diagramming the components of data elements. Detailed presentation of data element syntax appears in Section 4.3.1.
In these diagrams, required components of a data element appear as follows. (The double border signifies "required".)
+========+ +===//===+
| | | |
+========+ +===//===+
always one one or more
octet long octets long
Optional components of data elements are represented as follows. (The single border signifies "not required".)
+--------+ +---//---+
| | | |
+--------+ +---//---+
always one one or more
octet long octets long
The first octet in a data element is the identifier octet. In diagrams of data elements, all eight bits of the identifier octet are always shown. Bits with fixed values show the fixed values as 1s and 0s. Bits with variable values are shown as x's and y's.
The first bit in an identifier octet is the P-bit. Its value indicates whether a data element contains a property list. (A P-bit value of 1 indicates the presence of a property list.) The remaining seven bits contain the rest of the identifier.
Other octets in a data element belong to one of four classes, Length Code, Qualifier, Property-List, and Contents. In diagrams of syntax the data element components are labeled according to their class.
Component Class Label
Length code Length
Qualifier Qual
Property-List P-List
Contents Contents
Data elements must follow this form.
+========+===//===+---//---+---//---+---//---+
|Pxxxxxxx| Length | Qual | P-List |contents|
+========+===//===+---//---+---//---+---//---+
The value of the Length component is the total number of octets following the length code octet in the data element.
Appendix G. Summary of Data Elements by Compliance Category
Compliance categories for syntactic elements are basic and optional. Every CBMS is required to recognize and process basic elements. A CBMS is not required to process optional elements although many are strongly recommended by the semantics.
This appendix summarizes data elements by listing them according to their compliance category.
G.1 BASIC Data Elements
ASCII-String (primitive) 02 002
16 8
Date (constructor) 28 050
16 8
End-Of-Constructor (primitive) 01 001
16 8
Field (constructor) 4C 114
16 8
Message (constructor) 4D 115
16 8
G.2 OPTIONAL Data Elements
Bit-String (primitive) 43 103
16 8
Boolean (primitive) 08 010
16 8
Compressed (constructor) 46 106
16 8
Encrypted (constructor) 47 107
16 8
Extension (constructor) 7E 176
16 8
Integer (primitive) 20 040
16 8
No-Op (primitive) 00 000
16 8
Padding (primitive) 21 041
16 8
Property (constructor) 45 105
16 8
Property-List (constructor) 24 044
16 8
Sequence (constructor) 0A 012
16 8
Set (constructor) 0B 013
16 8
Unique-ID (constructor) 09 011
16 8
Vendor-Defined (constructor) 7F 377