3. Transmission time per scanning line
A total scanning line is defined as the sum of DATA bits plus any required FILL bits plus the EOL bits. The minimum transmission times of the total scanning line should conform to the following:
a. 20 milliseconds recommended standard with an optional fall-back to the 40 milliseconds option;
b. 10 milliseconds recognized option with a mandatory fall-back to the 20 milliseconds standard;
c. 5 milliseconds recognized option with a mandatory fall-back to the 10 milliseconds option and the 20 milliseconds standard;
d. 40 milliseconds recognized option.
The identification and choice of this minimum transmission time is to be made in the pre-message (Phase B) portion of the T.30 control procedure. The maximum transmission time of any total scanning line should be less than 5 seconds.