Skip to main content

ICS Datagrams and Timestamps

At present, the ICS is provided using either ICMP or GGP datagrams. The only difference between these is that ICMP uses protocol number 1 and GGP uses protocol number 3. In the following these will be referred to interchangably as ICS datagrams. ICS datagrams include an internet header followed by an ICS header in the following format:

 0                   1                   2                   3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Type | Code | Sequence |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Originate Timestamp |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Receive Timestamp |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Transmit Timestamp |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

ICS Datagram Format

The originator fills in all three timestamp fields just before the datagram is forwarded to the net. Each of these fields contain the local time at origination. Although the last two are redundant, they allow roundtrip delay measurements to be made using remote hosts without timestamping facilities. The "Type" field can be either 8 (GGP Echo) or 13 (ICMP Timestamp). The "Code" field should be zero. The "Sequence" field can contain either zero or an optional sequence number provided by the user. The length of the datagram is thus 36 octets inclusive of the 20-octet internet header and exclusive of the local-network leader.

The host or gateway receiving an ICS datagram fills in the "Receive Timestamp" field just as the datagram is received from the net and the "Transmit Timestamp" just as it is forwarded back to the sender. It also sets the "Type" field to 0 (GGP Echo Reply), if the original value was 8, or 14 (ICMP Timestamp Reply), if it was 13. The remaining fields are unchanged.

The timestamp values are in milliseconds from midnight UT and are stored right-justified in the 32-bit fields shown above. Ordinarily, all time calculations are performed modulo-24 hours in milliseconds. This provides a convenient match to those operating systems which maintain a system clock in ticks past midnight. The specified timestamp unit of milliseconds is consistent with the accuracy of existing radio clocks and the errors expected in the timestamping process itself.