Appendix B. Data Compression
When message-bags are shipped between MPMs the data should be compressed according to the following scheme:
shipping-unit := compression-type message-bag
compression-type := A one octet compression type indicator.
compression-type value description
---------------------- -----------
0 no compression used
1 basic compression
basic compression
This basic compression procedure is the same as that defined for use with the ARPANET FTP [8]. Three types of compression-units may be formed, sequence-units, replication-units, and filler-units. The data is formed into a series of compression-units independent of the structure or object and element boundaries.
sequence-unit
A sequence-unit is a one octet flag and count followed by that many data octets.
+-+-------+--------+--------+----
!0! n ! n data octets ...
+-+-------+--------+--------+----
The flag and count octet has its high order bit zero and the remaining bits indicate the count (in the range 0 to 127) of following data octets.
replication-unit
A replication-unit is a one octet flag and count followed by one data octet, which is to be replicated count times.
+--+------+--------+
!10! n ! data !
+--+------+--------+
The flag and count octet has its high order two bits equal one-zero and the remaining six bits indicate the count (in the range 0 to 63) of number of time to replicate the data octet.
filler-unit
A filler-unit is a one octet flag and count, indicating that a filler octet is to be inserted count times.
+--+------+
!11! n !
+--+------+
The flag and count octet has its high order two bits equal one-one and the remaining six bits indicate the count (in the range 0 to 63) of number of time to insert the filler octet.
The filler octet is zero, the octet with all bits zero.