2.2. Distant Host Electrical Requirements
Discussion:
The paragraphs below specify a Distant Host option of the JANUS interface which differs substantially from the 1822 Distant Host interface. Several considerations prompted this change. Report 1822 specifies transformer coupling at the receiver, so requirements on signal rise time and hold times were made. To relax these, and to achieve greater tolerance to differences in ground potential, optical isolators are now often used, even in 1822 interfaces. Neither the Report 1822 Distant Host driver, nor the driver adopted for JANUS, generate more than 1.0 volt. Commonly available optical isolators require at least 1.1 volts to overcome their forward drop before they will operate. Thus an optical isolator driver is needed in both the 1822 and the JANUS receivers. The ground potential difference between the communicating interface may exceed the maximum ratings of the input amplifier, so the input circuit must be powered from a floating power supply. Appropriate DC-DC converters for this purpose are available at reasonable cost.
2.2.1. DH Signal Timing
Requirement:
Receiver circuits in distant host interfaces shall be implemented with optical isolators or other means which are not sensitive to rise and hold times, as transformer coupling is. Therefore, the requirements for rise and hold times on distant host signals appearing in Report 1822 are suspended.
2.2.2. DH Signal Levels and Waveforms
Requirement:
Signal levels and waveforms at the driver and the receiver shall follow the specifications in EIA standard RS-422. In particular, the driver must supply a differential of at least 2 and not more than 6 volts; and the receiver must operate correctly on as small a differential as 0.2 volts.
2.2.3. DH Electrical Isolation
Requirement:
The receiver circuit must operate correctly over a common mode voltage range of -100 to +100 volts, and must not be permanently damaged by a common mode voltage of from -300 to +300 volts.
Exception:
If the interface is absolutely never intended for use in an environment where common mode voltage exceeds 7 volts in magnitude, or where the voltage from either signal wire to the signal ground exceeds 10 volts in magnitude, then the electrical isolation required in this paragraph may be suspended, and the corresponding requirements of EIA specification RS-422 applied in its place. Such an implementation is explicitly an exceptional JANUS interface, and is not the standard JANUS interface.
Discussion:
A suggested way to achieve this isolation is an RS-422 receiver chip, such as the Motorola MC3487 or the Advanced Micro Devices Am26LS32, followed by an LED driver as needed, followed by an optical isolator such as the Hewlett-Packard 5082-4360. The receivers and LED drivers for all input lines may be powered from one source, but this power must be floated with respect to ground of the home interface.
2.2.4. DH Cable Shield Grounding
Requirement:
At each end the cable shield in a distant host connection shall be connected through a circuit described below to signal ground. The circuit consists of two components connected in parallel. (1) A 100K, 1/8 watt resistor provides a path to leak off slow accumulations of static charge. (2) A .01 mfd, 600 V ceramic capacitor bypasses sharp noise spikes.
Exception:
In cases of severe noise, one end of the shield or the other (but not both!) may have to be tied directly to ground, sacrificing the symmetry.
Discussion:
Grounding the cable shield only at the host end, as in Report 1822, is undefined when the interface is symmetrical. Instead, the circuit above will be used.
2.2.5. DH Cable
Requirement:
Cable requirements in EIA specification RS-422 must be followed with respect to quality and electrical characteristics, and those in Report 1822 with respect to number of conductors. In particular, at least 10 twisted pairs with impedance of approximately 100 ohms must be supplied.
Discussion:
A suitable cable is PE-39, described in REA Bulletin 345-67. This cable is similar to that mass produced for telephone cable, which is of good, uniform quality, and readily available at reasonable cost. The cable specified in Report 1822 is not as desirable. Note the change in specified characteristic impedance: Report 1822 specified 120 ohms, while the JANUS interfaces follow RS-422 with 100 ohms.
2.2.6. DH Cable Termination
Requirement:
Termination shall be as specified in RS-422, in particular at the receiver. Termination as in Report 1822, at the driver, shall NOT be used.
Discussion:
The source-end termination specified in Report 1822 was to eliminate the voltage drop caused by the cable's series resistance. RS-422 explicitly allows for this sort of signal attenuation as a part of the specification.