Skip to main content

Sequencing, Broadcasting and Index 0

4i. Sequencing​

Once communication between the Host and the FE has been established and each side is "Ready for Business" (see Section 4b) the Host may at any time send BEGIN or LISTEN commands for new indexes. The FE will acknowledge a BEGIN or LISTEN with a REPLY and the index is then set-up providing that the REPLY indicates no errors. Other BEGIN or LISTEN commands for the new paths on the same index may be sent at any time after the index is set-up.

The FE will send a RESPONSE command for each path on completion of its attempts to fulfill the Host's instructions. If an attempt failed (indicated by the CODE field) then the path remains closed and another BEGIN or LISTEN for that path can be sent. If the attempt was successful, then MESSAGE or INTERRUPT commands can be sent after the Host has REPLYED to the RESPONSE.

An INTERRUPT or END command may be sent on any opened path after receiving a REPLY for the previous command on the same path in the same direction. A MESSAGE command may be sent if in addition the READY bit was on in the last REPLY command.

New paths on the same index may be opened at any time after the index has been set-up, or particular paths may be ENDed and then have new BEGINs or LISTENs for them issued. An index remains set-up, even if all its paths are closed, until an END command with PATH=0 is issued for the index.

Communication between the Host and the FE is terminated by an END with INDEX=0 and this will abort any remaining open paths and indexes.

4j. Broadcasting​

Broadcasting is an optional feature of the protocol. If it has been enabled by the installation parameter, then the Host may send a MESSAGE or INTERRUPT command on a particular index with PATH=0. This instructs the FE to send the data contained in the TEXT field of the MESSAGE command (or an interrupt) on every network connection corresponding to an open path of the specified index.

This feature will only occur on MESSAGEs from the Host to the FE (since no utilization of it in the other direction is envisaged).

A broadcast MESSAGE is replied to with one or two REPLYs in the same way as any other MESSAGE command. Flow control within the index is maintained as if broadcast MESSAGEs were sent on a separate path, i.e., flow control on other paths is not directly affected.

Note that for a broadcast MESSAGE command the FE will perform translation on the data for each path in accordance with the BEGIN or LISTEN which initiated that path. Thus, care must be taken when all paths of the particular index do not have the same format on the Host side specified in their TRANS-TYPE (see Section 6b).

5. Index 0​

5a. Introduction​

Index 0 provides a control link between the Host and the FE, and thus has no network connections directly associated with it. The commands on this index are used to establish and terminate the connection between Host and FE and to control other indexes.

5b. Path 0​

Path 0 of Index 0 is used to pass global commands - i.e., those which do not refer to any particular index or path. The currently defined commands are :

MESSAGE INDEX=0 COUNT PAD TEXT

where TEXT = COMMAND [PARM1] [PARM2]
COMMAND is 8 bits long
PARM1 and PARM2 are 16 bits long

a) COMMAND=1 , PARM1=Hostid

This is the "Ready for Business" command which must be sent by both Host and FE to establish communication between them. Count gives the length of the TEXT field as usual. If COUNT=8, then just the COMMAND field is present. If COUNT=24, then both the COMMAND and Hostid are present.

The FE will never send a Hostid. The Host may send its Hostid in the event that the FE is connected to more than one IMP or if alternate routes to the network exist (e.g., via patch panels).

Until both sides have sent this command no other command is valid.

b) COMMAND=2 , PARM1=M , PARM2=N

This is the "CLOSING" command which is a purely information indication that the sender's FEP module has been told that communication will be terminated in M minutes for a period of N minutes (N=0 implies unknown).

No action is required of the receiver, however he may be able to distribute the information to his users.

c) COMMAND=3

This is the "CONTINUE" command which indicates that any previous CLOSING command is now no longer true.

END INDEX=0 PATH+0 CODE

This command terminates the connection between the HOST and FE. All other paths/indexes are automatically aborted and the FE will close all network connections. The values of the CODE field are the same as in the general END command.

5c. Path 1​

Path 1 is reserved for commands specific to a particular path or index. No commands are presently defined; they will be at a later date when more experience has been gained on the need for them.

5d. Path 2​

Path 2 of Index 0 is used for Operator-to-Operator communication between the Host and the FE. It is an optional feature which is enabled by an installation parameter.

MESSAGE commands are formatted in the normal manner with the sender requesting that the TEXT field be displayed to the receiver's system operator.