VII. Implementations Notes

The sender involves approximately ten pages of assembly code for the network message interface. Two processes are involved: one which fills a buffer by reading the input data stream, and a second process which sends network messages from the buffer and processes replies from the receiver. The two processes are joined by a coroutine mechanism, but in the future will be two parallel TENEX processes.

The receiver program consists of approximately four pages of BCPL code in addition to IO device drivers and routines which implement queueing primitives.

Each message contained between zero and 255 bytes of data arranged (as a coding convenience) in a way which is directly compatible with the BCPL string handling routines. Messages contained a single byte of checksum which was the low eight bits of the twos complement negation of the twos complement sum of all other bytes in the message. We recommend that some more reliable checksum function be employed in the future; even using eight-bit ones complement arithmetic would be better.

Source files for the various programs are available from the authors at Bolt Beranek and Newman, 50 Moulton Street, Cambridge Mass., 02138.