TCP to User Messages
2.4.1 TYPE CODES
All messages include a type code which identifies the type of user call to which the message applies. Types are:
0 - General message, does not apply to a particular user call
1 - Applies to OPEN
2 - Applies to CLOSE
3 - Applies to INTERRUPT
10 - Applies to SEND
20 - Applies to RECEIVE
30 - Applies to STATUS
2.4.2 MESSAGE FORMAT [notional]
All messages include the following three fields:
Type code
Local connection name
Event code
For message types 0-3 [General, Open, Close, Interrupt] only these three fields are necessary.
For message type 10 [Send] one additional field is necessary:
Buffer address
For message type 20 [Receive] three additional fields are necessary:
Buffer address
Byte count
End-of-letter flag
For message type 30 [status] additional data might include;
Local socket, foreign socket
Send window [measures buffer space at foreign TCP]
Receive window [measures buffer space at local TCP]
Connection state [see section 4.3.6]
Number of letters awaiting acknowledgment
Number of letters awaiting receipt
Retransmission timeout
2.4.3 EVENT CODES
The event code specifies the particular event that the TCP wishes to communicate to the user.
In addition to the event code, three flags may be useful to classify the event into major categories and facilitate event processing by the user:
E flag: set if event is an error
L/F flag: indicates whether event was generated by Local TCP, or
Foreign TCP or network
P/T flag: indicates whether the event is Permanent or Temporary
[retry may succeed]
Events are encoded into 8 bits with the high order bits set to indicate the state of the E, L/F, and P/T flags, respectively.
Events specified so far are listed below with their codes and flag settings. A * means a flag does not apply or can take both values for this event. Additional events may be defined in the course of experimentation.
0 0** general success
1 ELP connection illegal for this process
2 OF* unspecified foreign socket has become bound
3 ELP connection not open
4 ELT no room for TCB
5 ELT foreign socket unspecified
6 ELP connection already open
EFP unacceptable SYN [or SYN/ACK] arrived at foreign
TCP. Note: This is not a misprint, the local meaning is different
from foreign.
7 EFP connection does not exist at foreign TCP
8 EFT foreign TCP inaccessible [may have subcases]
9 ELT retransmission timeout
10 E*P buffer flushed due to interrupt
11 OF* interrupt to user
12 **P connection closing
13 E** general error
14 E*P connection reset
Possible events for each message type are as follows:
Type 0[general]: 2,11,12,14
Type 1[open]: 0,1,4,6,13
Type 2[close]: 0,1,3,13
Type 3[interrupt]: 0,1,3,5,7,8,9,12,13
Type 10[send]: 0,1,3,5,7,8,9,10,11,12,13
Type 20[receive]: 0,1,3,10,12,13
Type 30[status]: 0,1,13
Note that events 6(foreign), 7, 8 are generated at the foreign TCP or in the network[s], and these same codes are used in the error field of the internet packet [see section 4.2.1].