Asynchronous Stop Replies
These replies (op-code between 100 and 177 octal) are sent by the PDP-11 wherever a process being debugged stops running for any reason other than in response to the
STOP (Process)
command. Each of these replies includes the entire state vector for the process.
Op-Code 100 - TRAP (Process, Reason, 0, STATE VECTOR)
This informs the remote host that a process has "trapped", or terminated abnormally. The reason is a system error code, or could be a trap vector address in the stand-alone case.
Op-Code 101 - HALT (Process, 0,0, STATE VECTOR)
This informs the remote host that the given process has terminated normally.
Op-Code 102 - BPT (Process, 0, 0, STATE VECTOR)
This informs the remote host that the given process has hit a breakpoint trap.
Op-Code 103 - TTRAP (Process, 0, 0, STATE VECTOR)
This informs the remote host that the given process has hit a trace trap, i.e. has just executed one instruction in response to the
SINGLE STEP (Process)
command.