Approach
So that the plasma terminal would communicate like a Teletype when tied to a TIP, and still be able to work with the PLATO System through the Network, it was decided to build an interface that could be operated in two modes. There would be an "ASCII" mode to send and receive Network oriented data (such as TIP log-on or running at some arbitrary Network site); and a "PLATO System" mode to allow data, imbedded in 8-bit codes, to pass transparently through the Network.
Since there is a possibility that when in the PLATO mode, re-formatted codes can appear to be standard ACSII characters that will be seized upon by intervening TIPs or HOSTs, the interface must insure that no recognizable codes be sent. For example, the @ is recognized by a TIP as the beginning of a TIP command string. Therefore the interface must either "double-up" this code (@@) or not send it at all.
With the above requirement, and with other limitations, the prototype interface, now in use at UCSB, operates as follows:
-
In ASCII mode, the plasma terminal has been made to send and receive 8-bit ASCII code. In this mode, there is no graphics capability. The keyboard that is provided can only send 124 codes, therefore 4 seldom used ASCII codes have been excluded, and certain ASCII characters cannot be displayed.
-
In PLATO mode, PLATO data is embedded in 8-bit codes. The capability of running the keyboard in ASCII mode while the display remains in PLATO mode has also been provided.