Skip to main content

C. New NETRJS

Last Fall, CCN installed a new implementation of its NETRJS server. An internal NETRJS rewrite was necessitated by other system changes and was timed to coincide with installation on September 5 of the "last release" of OS/360, Release 21.7. The new version of NETRJS contains a number of internal improvements over the original version written two years ago. There are also a few external differences, as follows:

1. No More Squish​

The long-standing "squish" problem in NETRJS has been fixed. This problem arose because of the "squishiness" of Network data transfer, i.e. the variable delay between originator and receiver processes due to NCP buffering. The result was that a short print output file could be "transmitted" by RJS, dequeued, and discarded at CCN before the first message had actually reached the remote host. If the remote host crashed or the user tried to cancel (and save) the output stream, it was too late; the output was lost in the "squish". We were careless about this in the first version. Now NETRJS awaits the RFNM from the end-of-data mark before telling RJS to discard the job output.

2. Timeouts​

The new verson is a little tougher on timeouts, to free CCN resources when users are slow.

a. Signon Timeout​

If the user, after connecting to NETRJS and receiving the READY message, fails to send a valid SIGNON command within 3 minutes, CCN will close the Telnet connections.

b. Data Transfer Timeout​

(1) CCN will abort the READER data transfer connection if the user site leaves the connection open without sending any bits for 5 minutes.

(2) CCN will abort the PRINTER or PUNCH data transfer connection if the user site stops accepting bits for 5 minutes.

3. New Messages​

The NETRJS messages to the remote terminal have been revised to better distinguish problems at CCN, at the user site, or in the Network. See Reference 8 for a complete list.

4. Subsystem Interrupt​

The user can send a Control-C to terminate his NETRJS session either before or after signon. Continuation is not possible after the Control-C.

This provides an escape for a user who for some reason can't signon or signoff or close his Telnet connection. If the user entered via the RJS command in Socket 1, Control C will return him to the Server Telnet command level.

One other improvement will reduce user frustration: NETRJS now returns an INVALID SIGNON message if the user enters anything but a valid SIGNON command after initially connecting to the NETRJS server.