Skip to main content

IV. The Significance of Measurement Results

First of all let me state my complete agreement with Barry Wessler (Ref. "Revelations in Network Host Measurements" NWG/RFC 557, NIC 18457) that the measurement results should be taken in the spirit: "Here is a place to make the Network better" rather than: "Look, isn't the Network terrible." We take these measurements in the same spirit and have found the measurement effort to be quite fruitful. In several instances, with the aid of our measurement facilities, we have been able to improve the performance of our Network programs by an order-of-magnitude (just as Don Allen at BBN improved Greg Hicks' RJS program).

Our measurement results are in close agreement with the BBN FTP measurements (8.2 cpu seconds/Mb for 8-bit byte and 2 CPU seconds/Mb for 36-bit byte transfers). We also find the 36-bit byte transfer to be an order-of-magnitude more efficient than 8-bit byte transfer. The processing cost (assuming $6.00 per CPU minute) for transferring a Megabit of information comes to about $1.90 for ASCII-8 mode as compared to only $0.30 for Image-36 mode. The difference in transfer rate is equally astounding being 9.4 Kbps for Image-36 as compared to only 2 Kbps for ASCII-8.

It is therefore recommended that Image-36 mode be used as much as possible to transfer data between PDP-10s (of which there are many on the ARPANET). It is strongly urged that protocols and programs allow (and use) the Image-36 mode for all data transfers including mailing files (MLFL), listing directories (LIST, NLST), and sending/retrieving NIC Journal documents. Many of the MID-DMS user programs such as "COPY" and "FTP" take advantage of the fact that the remote Host is a PDP-10 (there is a table of PDP-10's in "COPY") and use the more efficient Image-36 mode. Such a procedure is highly recommended.

The effective IMP-IMP data transfer rate is about 37.5 Kbps over the 50 Kbps telephone line (Ref. McQuillan John M., "Throughput in the ARPA Network--Analysis and Measurement," BBN Report 2491, NIC 14188, January 1971). The Host-to-Host data transfer measurement performed by BBN (above reference, p. 28) have indicated a transfer rate of 30-35 kbps BBN-to-BBN (0 IMP hops) and 12-16 Kbps BBN-to-SRI (5 hops) using single link. As FTP transfers data via a single link, a maximum transfer rate between 12 and 35 Kbps (depending on number of IMP hops) can be expected if that file transfer is the only activity going on. In this light our maximum transfer rate of 27 Kbps to BBN (2 hops) is probably the most one can expect out of any program. The average transfer rate of 9.4 Kbps (for Image-36) transfer also appears reasonable in view of the fact that during many of the transfers other network activity is also going on, and that many of the transfers are performed when the respective computer systems are quite heavily loaded. Our measurement data does reveal that transfer rate is appreciably higher during the times a computer is likely to be lightly loaded.

The above does not mean that improvements are not possible or not required in the state of the ARPANET data transfer. Our measurement data has revealed areas in which improvements can be and should be made. For example, the transfer of data to other MIT Hosts (0 IMP hops) and back to ourselves should be faster than what we currently achieve (transfer to BBN is faster!). The probable reason for the above discrepancy is that our allocation (Host-Host protocol) is very small (2944 bits) as compared to that provided by BBN (17724 bits). This means that to transfer data our Network Control Program (NCP) has to wait for an allocation many more times while communicating to an ITS system than to a TENEX system. Large allocations are always desirable but even more so while transferring files. NCP designers can (and should) modify NCP's to allow large allocates (larger NCP buffers) for file transfer even at the expense of smaller allocates for other types of connections (such as a terminal connected to a computer system) which do not require or use the larger allocation. In addition, a new allocate should be sent as soon as data is read by the receiving program (the NCP should not wait for the allocation to become zero before sending the new allocate).

We also observed that small files are transferred at a significantly lower transfer rate than large files but beyond a file size of 40 Kbits, the file size makes little difference in transfer rate or processing cost per bit transferred. The figure of 40 Kbits is probably related to the size of sending and receiving buffers used by the programs. In general, for most practical values of buffer size, the larger the buffer size and allocations, the faster and more efficient will be the transfer. Unfortunately, large NCP buffers are not easily available in many systems and come at a premium. The information on average file size (240 Kbits for Image and 40 Kbits for ASCII files) may be helpful in optimum allocation of buffer space.