Part 1: The Survey Database
Every twenty minutes, DMS's program SURVEY wakes up and performs the initial connection protocol from the PDP-10 at DMS to the logger socket (socket 1) of each 28 network hosts.
SURVEY records a date time, host, status,and response time for each host. A host may be in one of these states:
- undetermined or not surveyed
- disconnect from the network or dead
- network control program not responding
- ICP to logger aborted by the host
- ICP to logger timed out by SURVEY after 20 seconds
- logger available and responding within 20 seconds
SURVEY records response times responding in tenths of seconds.
When the data for all 28 hosts has been assembled, SURVEY transmits that data to CCA's datacomputer. If for some reason the datacomputer cannot accept the information, it is held at DMS and sent another time.
The datacomputer's survey database is inverted by host, status, month, and year. That is to say that the datacomputer maintains several indices to records of one attempt to establish a full duplex connection to one host's logger: it maintains one such index for each host, one for each status, one for each month, and one for each year. The datacomputer can select records that are specified in boolean expressions by performing boolean operations on the inversion, and without consulting the data itself. The inversion thus facilitates rapid interaction between the survey retrieval program described below and the survey database at the datacomputer.
SURVEY expresses the record of each attempt to access one host in 17 ASCII characters. The record of one survey then occupies 17 * 28 = 476 characters, and each day the datacomputer receives 3 * 24 * 476 = 34,272 characters from DMS.