Skip to main content

Sequencing of Commands and Replies

The communication between the user and server is intended to be an alternating dialogue. As such, the user issues an FTP command and the server responds with a prompt primary reply. The user should wait for this initial primary success or failure response before sending further commands.

Certain commands require a second reply for which the user should also wait. These replies may, for example, report on the progress or completion of file transfer or the closing of the data connection. They are secondary replies to file transfer commands.

The third class of replies are informational and spontaneous replies which may arrive at any time. The user-PI should be prepared to receive them. These replies are listed below as sponteneous.

One important group of spontaneous replies is the connection greetings. Under normal circumstances, a server will send a 300 reply, "awaiting input", when the ICP is completed. The user should wait for this greeting message before sending any commands. If the server is unable to accept input right away, he should send a 000 "announcing FTP" or a 020 "expected delay" reply immediately and a 300 reply when ready. The user will then know not to hang up if there is a delay.

The table below lists alternative success and failure replies for each command. These must be strictly adhered to; a server may substitute text in the replies, but the meaning and action implied by the code numbers and by the specific command reply sequence cannot be altered.

                COMMAND-REPLY CORRESPONDENCE TABLE

COMMAND             SUCCESS         FAILURE

USER                230,330         430-432,500-505,507
PASS                230,330         430-432,500-507
ACCT                230             430-432,500-507
REIN                232,233         401,436,500-507
   Secondary Reply  300
BYE                 231,232         500-505,507
BYTE                200,331         402,500-505,507
SOCK                200,331         500-505,507
PASV                200,331         500-507
TYPE                200,331         402,500-505,507
STRU                200,331         500-505,507
MODE                200,331         402,500-505,507
RETR                250             402,433,450,451,454,455,457,
                                      500-505,507,550
   Secondary Reply  252,257         452
STOR                250             402,433,451,454,455,457,
                                      500-505,507,550
   Secondary Reply  252,257         452,453
APPE                250             402,433,451,454,455,457,500-507,
                                      550
   Secondary Reply  252,257         452,453
ALLO                200,331         402,500-507
REST                200,331         500-507
RNFR                200             402,433,450,451,455,500-507,550
RNTO                253             402,433,450,451,455,456,500-507,
                                      550
ABOR                201,202,331     500-507
DELE                254             402,433,450,451,455,500-507,550
LIST                250             402,433,450,451,454,455,457,
                                      500-507,550
   Secondary Reply  252,257         452
NLST                250             402,433,450,451,454,455,457,
                                      500-507,550
   Secondary Reply  252,257         452
SITE                200,331         402,500-507
STAT                100,110,        450,451,455,500-507,550
                      150,151,331
HELP                030,050         500-507
NOOP                200             500-505,507
Spontaneous Replies 000,010,020,    400,401,434-436
                      300,301,251,255