Skip to main content

Section 2. Display Module

The DS-1 display module is an Owens-Illinois DIGIVUE_ display/memory unit Model 512-60. It contains the plasma panel, drive electronics, and display logic. These three assemblies are described in the following paragraphs.

PANEL​

The DIGIVUE_ display panel (or plasma panel) is a matrix device. It is constructed from two pieces of 1/4" plate glass, upon which very fine gold electrode lines are deposited. These electrodes are then completely covered by a dielectric film. These two plates are then sealed together with a gap of a few thousandths of an inch between them, and with their electrode patterns orthogonally oriented.

This "sandwich" is then baked out and pumped down to high vacuum, backfilled with a gas mixture consisting largely of Neon, and sealed off. The addition of flexible ribbon cable connectors completes the fabrication of the panel. The device is fat, roughly _" thick, and virtually transparent.

The panel is operated in such a way that any location (i.e., any x, y intersection) may be individually turned "on" or "off" as a source of visible light. Further, such a location has a "memory" and is sustained in the 'on" or "off" state until a new selection signal changes it.

An AC voltage is applied between all x and all y electrodes in parallel, so that an AC signal less than the breakdown potential is applied across the gas at all times. This is called the sustaining voltage, VS. When a single x,y point is to be addressed, a voltage pulse, VP, is applied to the appropriate x and y lines, such that the total addressing voltage at their intersection is given by

V ADD = VS + 2VP,

which exceeds the breakdown potential of the gas, initiation a discharge.

Since the electrodes are covered by a dielectric, no discharge current can flow in the external circuit. Rather, the ions and electrons produced by the discharge are carried by the applied field and are deposited as stored charge on the dielectric surfaces, until the resultant net field is nearly zero, quenching the discharge after about one microsecond. As the AC sustaining voltage changes polarity, however, this stored charge constitutes a bias voltage, adding to the sustaining signal and producing a new discharge, which results in stored charge causing another discharge on the next half cycle, etc. Thus, once addressed, a single x,y location continues to produce a discharge twice in every sustainer period, or about 100 thousand times per second. Naturally, this appears as a continuous glow to the eye. A sustained location may be turned off by addressing in such a way that the stored charge is allowed to return to zero. Thus, a location, or 'cell", may be turned on or off in a bistable, random access manner.

The plasma display has a number of extremely useful visual characteristics. Its transparency permits the use of rear-projected data from microfilm, color slides, maps, forms, etc., to be "mixed" with the dynamic, computer generated data to be displayed (characters, plots, graphics, etc.). In addition to the high brightness of the gas discharge, the contrast ration is extremely nigh. The panel used in the model 512-60 has 512 x 512 lines at 60 lines per inch. This high resolution and large size allows highly readable characters and graphics to be mixed, without distortion or jitter of the data. Dot matrix characters are especially attractive, since the "dots" of the discharge sites have very clean, crisp dimensions.

A significant system characteristic of the plasma display matrix is its random access memory property. Unlike storage tube displays, it may be selectively erased as well as written, changing a single point, curve, or character without altering the contents of other locations on the panel. Large quantities of text, time histories of measured data, or complex memory. This allows more efficient use of the processor and simpler data management within computer memory.

The 512-60 panel used in the DS-1 application will have an active area of 8.5 x 8.5 inches, containing 512 x 512 lines. There will be an additional 4 line peripheral border around the addressable area to provide conditioning of the discharge sites.

The back of the panel will be frosted with an optically diffusing surface suitable for the projection of optical images. A circularly-polarizing neutral density filter with anti-glare coating will be provided on the front of the display. The brightness and contrast will be sufficient for use in a normal lighted laboratory area.

Drive Electronics​

The Drive electronics for the display module will be the standard Owens-Illinois circuits requri3ed to operate a 512 x 512 line panel as part of our model 512-60 standard display unit. They consist of a sustaining generator, which maintains cells, once addressed, in the appropriate state ("on" or "off") after removal of the addressing signal, and pulse-forming circuits for the generation and appropriate mixing of addressing pulses at the selected panel sites.

The sustainer will operate with a basic period of 20 microseconds, with a peak voltage of approximately 130 volts. Exact voltage levels, frequency and waveshape are adjusted for optimal performance subject to power supply constraints and data rate requirements.

The address circuits are multiplexed to reduce the number of active circuits required and employ a non-linear mixing scheme for line selection. A pulse of 100 volts is applied with the proper time phase to achieve writing and erasing. The pulse is disabled in all but the selected line pair.

Provision is also made for bulk erasure in which the entire panel is erased in two sustainer periods. A power supply of high density design will provide the necessary sustaining, addressing, and logical level voltages. The design will employ high-frequency invertors and switching regulation for maximum efficiency and reduced size. It requires about 250 watts, and will be housed inside the processor module.

Display Logic​

The logic included in the display module provides the timing and control required for the sustaining generator and the address pulses, and also provides the logic level interface to the processor module. The interface is TTL compatible. It contains 2 nine-bit address ports X0-X8 and Y0-Y8, which [not legible*], in absolute binary code the x,y intersection which is to be addressed. These addresses are accepted when given a write command or an erase command by the control lines W or E, respectively. These inputs must all be held steady until acceptance of the data and completion of the operation has been indicated by the status line, a logic level output from the display unit. Ad additional control line, B, is used in conjunction with the H line to cause a bulk erasure of the entire screen.

The model 512-60 display unit proposed in this document is of the serial address type, and thus can write or erase a single point each 20 u/seconds. This permits vectors to be drawn at more than 800 inches/second. Characters in a 5x7 dot matrix can be written at a rate of about 1400 characters per second.

A parallel address type display unit is presently being developed at Owens-Illinois. This module, when available, will be compatible with the DS-1 system with no modification to the processor required. This display will address 16 lines in parallel, which will allow more than 6,000 characters per second to be displayed, or a complete page to be generated in .330 seconds.