Cases Where Human Error Detection Is Inadequate
The effectiveness of this means for error detection and initiation of corrective measures when necessary is not adequate in the following cases:
a. For terminal-TIP communication at a medium or higher data rate (say 1200 bps or higher) it is quite possible that the human will skim computer output and not be an effective character-by-character error detector. In particular, when both user input and computer output contain numerical data it is possible that significant undetected errors could occur.
b. For terminals located at a distance from the TIP and connected either by a private line or the switched network more errors may be introduced than with a terminal local to the TIP (see Note 1). When a large number of user terminals are connected to TIP's through telecommunications facilities, whether within a single organization or, even more likely, when users and user groups not needing the full TIP capability are connected to a remote TIP, this problem may arise.
c. For terminals containing a substantial amount of logic, including possibly a minicomputer, a human user is very likely not in the direct terminal-TIP communications loop. This case is important, since both alphanumeric and full graphics terminals containing minis are now becoming popular.
d. An interesting potential application of the network is to provide support for minicomputers used for process control and other laboratory measurement functions. In providing software support for such minis as well as acquiring data from them usually there is no human user in the communication loop.
e. A number of sites already offer a remote job entry service. Although the present sites assume that the unit record devices such as card readers and line printers are files within a multiprogrammed system at another site, it appears natural that remote batch terminals be attached to the network through TIP's. Here again, there would be no human in the loop between the terminal and the TIP.