To prevent misunderstandings of this type in the future, the IMP/Host interface should be well documented, well understood and invariant. The only way to set up and maintain such an interface is to presume that BBN Report No. 1822 is complete and correct. We understand that it is neither, but operating on the basis of this assumption is the best way to force 1822 to improve.

In our view, the Hosts should proceed under the constraint that anything not specifically guaranteed by 1822 does not exist and should not be used. If there are problems using this approach, please don't "code around" the problem or treat your IMP as a "black box" and extrapolate its characteristics from a series of experiments. Instead, send your comments and problems to the NCC at BBN, and we will fix the IMP system, or 1822, whichever is necessary.