III. The Form Interpreter
Interpreter Overview
The interpreter is a simple minded machine having the virtue of helping the compiler writer by providing a rather powerful instruction set for hard-to-compile operations. Figure 1 shows the machine configuration:
+-------------+ +--------------+
| inputstream | | outputstream |
+-------------+ +--------------+
/\ /
\ /
\ /
\ \/
+-----------------------+
| CPU |
+-----------------------+
| /\
| |
| |
\/ |
+-----------------------+
Storage: | Instruction |
| Sequence |
+-----------------------+
| Label Table |
+-----------------------+
| Literal/Identifier |
| Pool |
+-----------------------+
| Variable length |
| string area |
+-----------------------+
Figure 1. Form Interpreter
The CPU is a box full of miscellaneous parts, the most important being the Arithmetic Logic Unit and the instruction decoding unit. The CPU also maintains a collection of state registers to keep track of what it is doing. Figure 2 shows the rough layout.
+-----------------+ +---------------+
| Instruction | | Instruction |
| Counter | | Register |
+-----------------+ +---------------+
|
|
V
+----------------+
| Operation Code |
| Decoding |
Run Time Stack +----------------+
+------------------+ / | \
| Operands | / | \
+------------------+ \/ V \/
| | +-----------------+
+------------------+ / Instruction \
| | | Interpreter |
+------------------+ | Routines |
| | \ /
+------------------+ +---------------+
| | | /\
+------------------+ | |
| | | |
+------------------+ V |
| | +---------------+
+------------------+ <------------- | Arithmetic |
| | -------------> | Logic Unit |
+------------------+ +---------------+
| |
+------------------+
| |
+------------------+
+------------------+ +------------------+
|Initial Input Ptr.| | Output pointer |
+------------------+ +------------------+
+------------------+ +------------------+
|Current Input Ptr.| | True/False Flag |
+------------------+ +------------------+
Figure 2. The Central Processor
The CPU is a stack machine driven by a Polish postfix instruction sequence. Operands placed on the Run Time Stack are used for arithmetic expression evaluation and for parameter passing between the interpreter and the built-in functions.
The Current Input Pointer and the Output Pointer keep track of the two data streams. Two input pointers are needed because of the backup requirement in the event of rule failure. All of these pointers are bit pointers into the two streams.
Various implementations of the Run Time Stack are independent of the interpretation of the DRS machine's instruction set. It is suggested that the stack will contain instruction operands from the instruction stream.
The format of a compiled instruction sequence for a form is shown in Fig. 3.
16 bits
+--------/\---------+
/ \
+---------------------+
| length n in bytes |
+-- +---------------------+
| | |
| | compiled |
| | 16-bit |
n < | instructions |
| | |
| | |
+-- +---------------------+
Fig. 3. Compiled Instruction Sequence Format
The format of the compiled Label Table is shown in Fig. 4.
16 bits
+-----/\-------+
/ \
+-----------------+
| length n |
| in bytes |
+-- +------------------+-----------------+
| | numeric value of | byte offset |
| | statement number | in inst. seq. |
| +------------------+-----------------+
| | : : |
n < | : : |
| | : : |
| | |
| | |
| | |
+-- +------------------------------------+
\_________________ _________________/
V
32 bits
Fig. 4. Compiled Label Table
Literals and Identifiers are compiled as shown in fig. 5.
2 2
+----/\----+ +----/\----+
/ \ / \
+-------------+--------------+
1 1 | length n | length n |
___/\____ ___/\____ | in bytes | in bytes |
+---------+----------+-------------+--------------+
/ | |//////////| | |
| | Type |//////////| bit length | byte offset |
| | |//////////| | |
| +---------+----------+-------------+--------------+
5*n < | : |
| | : |
| | : | Identifiers
| | |
| | |
\ | |
+-------------------------------------------------+
/ | |
| | literals are |
| | byte-aligned | Literals
m < | |
| | |
| | |
| | |
\ +-------------------------------------------------+
Legend:
Type 0 = undefined
1 = B (binary)
2 = 0 (octal)
3 = X (hexadecimal)
4 = E (EBCDIC)
5 = A (ASCII)
6 = ED (EBCDIC encoded decimal)
7 = AD (ASCII encoded decimal)
8 = SB (signed binary, two's complement)
Fig. 5. Compiled Literals and Identifiers
Types B, 0, X, AD, ED, and SB point to 32-bit word-aligned data shown below.
+---+---+-----+-------+ +-------------------+ word-aligned,
| T |///| L | ---+-----> | | 32-bit right-
+---+---+-----+-------+ +-------------------+ justified
Types E and A point to byte-aligned symbol streams as shown below.
byte-aligned, L <= 256
+---+---+-----+-------+ +------------------------+
| T |///| L | ---+-----> | |
+---+---+-----+-------+ +------------------------+
Instruction Format
Since literals and identifiers will be stored in the same data area, more than 256 literals plus identifiers might be encountered so more than 8 bits are needed to reference literal/id pool. Furthermore, such references must be distinguished from operators in the instruction stream, so a 16-bit instruction will be used, as shown below.
+--------+------------------------+
| 4 | 12 |
+--------+------------------------+
|
/
/
/
|
V
LD = 0 literal or identifier reference (12-bit positive integer)
IC = 1 12-bit two's complement integer constant
OP = 2 operator
AD = 3 address (12-bit positive integer)
ARB = 4 indefinite replication factor
NULL = 5 missing attribute of term
The operation code decoder picks up types 0, 1, 3, 4, and 5 and deposits them on top of the stack (TOS). LD is an index into the literal/identifier table, and AD is an index into the instruction sequence.
The decoder examines OP elements further:
4 4 8
+--------+--------+----------------+
| 0010 | |////////////////|
+--------+--------+----------------+
OP |
+----------> 0 = binary operator
1 = unary operator
2 = special operator
Binary Operators
Let the TOS contain y and the next level, x. The binary operators compute x <bop> y, popping both x, y from stack, and put the result back on top of the stack.
+---+ <-- TOS +-----+ <-- TOS
| y | | x-y |
e.g. x-y => +---+ ===> +-----+
| x | |/////|
+---+ +-----+
Binary Operator Encoding
4 4 4 4
+--------+--------+--------+--------+
| 0010 | 0000 | |////////|
+--------+--------+--------+--------+
|
+--------------------------+
|
V
0 = integer +
1 = integer -
2 = integer x
3 = integer : (or /), no remainder
4 = concatenate ||
All binary operations except concatenate expect the top two elements on the stack to describe type B, 0, X, or SB. The result is always a 32-bit type B element. The concatenate operator fails unless both types are identical. For example:
type L value T L V
+------+------+------+ +------+------+------+
TOS -> | B | 32 | 4 | | B | 32 | 12 | <- TOS
+------+------+------+ ==> +------+------+------+
| B | 8 | 16 | |//////|//////|//////|
+------+------+------+ +------+------+------+
Before-operation after-operation
+------+------+------+ +------+------+------+
TOS -> | A | 2 | DE | | A | 5 |ABCDE | <- TOS
+------+------+------+ ==> +------+------+------+
| A | 3 | ABC | |//////|//////|//////|
+------+------+------+ +------+------+------+
Before || operation after || operation
No binary operator has any effect on the TRUE/FALSE flag.
Unary Operators
4 4 4 4
+--------+--------+--------+--------+
| 0010 | 0001 | | |
+--------+--------+--------+--------+
| |
+--------------+ |
| |
V |
0 = integer minus V
1 = load identifier 0 = evaluated contents
(after dec - binary
conversion)
1 = length field
2 = type field
2 = Label Table Reference
For the unary minus operator the data described by the top of the stack is replaced with its 2's complement. The form fails if the TOS type is not SB, B, 0, or X.
The Load identifier expects the TOS to describe an index into the literal/identifier pool (that is, an LD instruction). The TOS described data is replaced by 32-bit type B values. The operation fails if the contents cannot be converted from encoded decimal to binary. B, 0, and X types are treated as unsigned integers, SB is treated as 2's complement.
The Label Table Reference operator expects a 32-bit type B value described by TOS and searches for this label in the label Table. If found, the TOS described data is replaced by the relative address in the instruction sequence of the label (in the form of an AD instruction). If not found, the form fails.
No Unary operator has any effect on the TRUE/FALSE flag.
Special Operators
4 4 4 4
+--------+--------+--------+--------+
| 0010 | 0010 | | |
+--------+--------+--------+--------+
| |
+-----------------------+ /
| /
V /
0 = store TOS |
1 = return V
2 = branch 0 = true, 1 = false, 2 = unconditional
3 = compare 0 = .EQ. 2 = .LE. 4 = .GE.
1 = .NE. 3 = .LT. 5 = .GT.
4 = move input ptr 0 = store current into initial
1 = store initial into current
5 = input call 0 = no compare
1 = compare
6 = output call
Store TOS
The TOS describes an index into the ID table and the next lower element in the stack describes a value to be stored. After execution, both elements are popped off the stack.
Return
The TOS describes a value to be returned to the routine which initiated the FORM MACHINE. The actual mechanism will be implementation dependent, but the FORM MACHINE will relinquish control after this instruction completes execution.
Branch
The TOS describes an index into the instruction sequence to be used as the new instruction counter (IC) if the branch conditions are satisfied. The branch instruction checks the state of the TRUE/FALSE flag register and either increments the IC by 1 or replaces it with the TOS described element. In any case, the TOS is popped.
Compare
The compare operator takes the two elements described by the two top stack entries and compares them (.EQ., .LT., etc.). If n is at the top of the stack, and m is just below, then m.xx.n is performed, and the TRUE/False flag is set accordingly. For .xx. = .EQ. or .NE. we must have identical type, length, and content for equality to hold.
The other boolean comparators will not be attempted if types are different (i.e., form fails), but for same types, B, 0, X cause binary-justified compares, and A, E, AD, ED cause left-justified string compares with the shorter string padded with blanks.
Move Input Pointer
This operator (no operands) replaces the Current Input Pointer with the Initial Input Pointer (back-up), or the Initial Input Pointer with the current one (entry to rule).
Input Call
This is the most complex operator thus far encountered. It requires four operands from the run-time stack:
TOS +----------------------------+
| binary or null | length to find
+----------------------------+
| LD to literal or null | value (literal)
+----------------------------+
| binary code | input data type
+----------------------------+
| binary, arbitrary, or null | replication count
+----------------------------+
The input call operator can be invoked with the "no compare" flag set, in which case the value expression parameter is ignored and only the input type and length expressions are used. In this case, the input routine tries to find in the input stream as many characters of the required type (bits, digits, etc.) as needed to fill the length expression requirement. If successful, the TRUE/FALSE flag is set TRUE, the stack is popped to remove the input parameters, and the string obtained is described by the TOS. If the input stream cannot be matched then the parameters are popped off the stack, and the TRUE/FALSE flag is set FALSE.
If the "compare" flag is set, the input stream must be searched for the value expression. However, we must take some care here to be sure we know what to look for. There are several cases:
- a) The length expression parameter is greater than the length of the value expression but the type of input desired is the same as the value expression type. For
B,0andXtypes, right-justify value expression in length-expression field, sign bit is extended left if typeBS. If typeA,E,AD, orEDpad on the right with blanks. - b) Same as a) but length is too small.
B,0, andXtype strings are truncated on the left.A,E,ADandEDare truncated on the right. - c) The type of the value expression and the type parameter differ. This case is deferred for discussion and presently is considered an error causing form failure.
If the input string matches, then the TRUE/FALSE flag is set true, the parameters are popped from the stack, and the resulting string is described by the TOS. Otherwise, the FALSE flag is set and the parameters are popped.
When a successful match is found the input subroutine always advances the Current Input Pointer by the appropriate amount. Since we are dealing at the bit level this pointer must be maintained as a bit pointer!
Output Call
This routine utilizes the same parameters as the input call, but operates on the output stream. The TRUE/FALSE flag is not distributed by this operator. As for input, there are four parameters on top of the stack, the length expression value, the value expression value, the desired output type, and the replication expression value. When there is a mismatch between the output type and the value expression type, a conversion must take place. The value expression is transformed into the desired output type and fitted into the field length specified by the length expression.
Truncation and Padding Rules
- a) Character -> character (
A,E,AD,ED->A,E,AD,ED) conversion is left-justified and truncated or padded with blanks on the right. - b) Character -> numeric and numeric -> character conversion is right-justified and truncated or padded on the left with zeros. Beware! Two's complement numbers may be bollixed by this.
- c) Numeric -> character conversion is right-justified and left padded with blanks or left-truncated. As for the unary operators, a numeric bit-string is treated as unsigned, except
SBwhich is treated as two's complement. Thus we have:
(1,ED,X"FF",3) = E'255'
(1,ED,X"100",3) = E'256'
but (1,ED,SB"10000000",4) = E'-256'
If the output routine is able to perform the desired action, it advances the Output Stream Pointer, and pops all parameters from the run-time stack.