Error Messages
These messages contain one or more words. If acknowledge messages are suppressed, then only one word is sent. (The assumption was made that brevity of response would also be desired for error messages if it were also desired for normal output.)
The first (or only) word contains a left half of 2. (Identifying this as an error message). The right half contains the number of the error condition recognized; these numbers are summarized below.
If the long form of the error message is being used, additional words are sent, the first contains a positive count of the remaining words in the left half and zero in the right half. Words following the count word contain five 7-bit ASCII characters per word (the last word may end in null characters) which spell out a descriptive error message. These messages are summarized below:
| Error Condition Number | Error Message |
|---|---|
| 0 | UNRECOGNIZED OPERATION CODE |
| 1 | PREVIOUS SETUP REQUIRED |
| 2 | INVALID MODE OR OPERAND FIELD |
| 3 | PREVIOUS EXECUTE FAILED |
| 4 | DISPLAY PROCESSOR OCCUPIED |
| 5 | OUTPUT AREA OVERRUN |
| 6 | DISPLAY ERROR: TWO SECOND TIME OUT |
| 7 | DISPLAY ERROR: IMPROPER DISPLAY STOP |
| 8 | DISPLAY ERROR: MEMORY PROTECTION VIOLATION |