There are at least the following three views on the use of byte size for network connections*:

  1. Byte size should not be used at all.

  2. Byte size is solely for the convenience of NCP's.

  3. Byte size choice is a user-level prerogative.

The First View​

According to the first view, network connections are bit streams, and messages should contain bit counts (i.e., a byte size of 1). This view existed before the "Glitch Cleaning" of RFC 107, and was discarded in favour of byte stream because of stated reasons of efficiency in storage management and message concatenation.

The Second View​

The second view represents a special interpretation of RFC 107. According to this interpretation, byte size is entirely a 2nd level (i.e., NCP) issue. There is no requirement that 3rd level user processes be able to specify byte size. This view is indicated in RFC 151 by Shoshani.

The Third View​

According to the third view user processes are always allowed to choose byte size for connection, either explicitly (specify a specific byte size parameter) or implicitly (byte size depends on I/O mode). An NCP is allowed to use a default byte size, if the user does not specify it.


* Byte size for connection is the byte size selected by sending NCP, as explained in RFC 107 (Output of Host-Host Protocol Glitch Cleaning Committee).