Specifications
1. Data Transfer
FTP uses the data transfer protocol described in RFC 171, for transferring data and/or control transaction. Both data and control transactions are communicated over the same connection.
2. Data Transactions
Data transactions represent the data contained in a file. There is no data type or byte size information contained in data transactions. The structure of data is instead communicated via control transactions. A file may be transferred as one or more data transactions. The protocol neither specifies nor imposes any limitations on the structure (record, group, etc) or length of file. Such limitations may however be imposed by a serving host. The end of a file may be indicated either by a file separator (as defined in data transfer protocol), or by closing connection (in type B0). In particular a serving or using host should not send the ETX, or other end of file character, unless such a character is part of the data in file (i.e., not provided by system).
3. Control Transactions
The control transactions may be typified as requests, identifiers, and terminates. A request fulfillment sequence begins with a request and ends with receipt of data (followed by End-of-File) or a terminate.
3A. Op Codes
Control transactions are distinguished by their first byte referred as op code. A standard set of opcodes is defined below. Implementation of a workable[4] subset of opcodes is specifically permitted. Additional standard opcodes may be assigned later. Opcodes hex 5A (octal 100) through hex FF (octal 377) are for experimental use.
Op Code Operation
Hex Octal
00 000 Change data type identifier
01 001 Retrieve Request
02 002 Store request (replaced if file already
exists)
03 003 Delete request
04 004 Rename_from request
05 005 Rename_to request
06 006 List_file_directory request
07 007 Username identifier
08 010 Password identifier
09 011 Error or unsuccessful terminate
04 012 Acknowledge or successful terminate
0B 013 Append request (add to existing file)
0C 014
through through Reserved for standard assignment
4F 077
5A 100
through through Reserved for experimental use
FF 377