2B. Syntax and Semantics
2B.1 Type B0 and B8 (indefinite bitstream modes)
Type B0 and B8 (indefinite bitstream modes) transactions terminate only when the NCP connection is "closed". There is no other escape convention defined in DTP at this level. It should be noted, that closing connection in bitstream mode represents an implicit file separator (see section 2B.5).
2B.2 Type B1 and B0 (transparent block modes)
Type B1 and B0 (transparent block modes) transactions terminate when the byte sequence DLE ETX is encountered. The sender shall replace any occurrence of DLE in data stream by the sequence DLE DLE. The receiver shall strip the extra DLE. The transaction is assumed to by byte-oriented. The code for DLE is Hex '90' or Octal '220' (this is different from the ASCII DLE which is Hex '10' or Octal '020). ETX is Hex '03' or Octal '03' (the same as ASCII ETX) [4].
2B.3 Type B2 and BA (descriptor and counts modes)
Type B2 and BA (descriptor and counts modes) transactions have three fields, a 9-byte (72-bits) descriptor field [5] and variable length (including zero) info and filler fields, as shown below. The total length of a transaction is (72+info+filler) bits.
|<B2 or BA><Info count><NUL><Seq #><NUL><filler count>|<info><filler> |
| 3-bits 24-bits 8-bits 16-bits 8-bits 8-bits |Variable length|
|<----- 72-bit descriptor field --------------------->|info and filler|
Info count is a binary count of number of bits in info field, not including descriptor or filler bits. Number of info bits is limited to (2**24 - 1), as there are 24 bits in info count field.
Sequence # is a sequential count in round-robin manner of B2 and BA type transaction. The inclusion of sequence numbers would help in debugging and error control, as sequence numbers may be used to check for missing transactions, and aid in locating errors. Hosts not wishing to implement this mechanism should have all 1's in the field. The count shall start from zero and continue sequentially to all 1's, after which it is reset to all zeros. The permitted sequence numbers are one greater than the previous, and all 1's.
Filler count is a binary count of bits used as fillers (i.e., not information) after the end of meaningful data. Number of filler bits is limited to 255, as there are 8 bits in filler count field.
The NUL bytes contain all 0's.
2B.4 Type B3 (modes available) transactions
Type B3 (modes available) transactions have a fixed length of 3 bytes, as shown below. First byte defines transaction type as B3, second byte defines modes available for send, and third byte defines modes available for receive.
+------------------+---------------------+---------------------+
| Type | I send | I receive |
| | | | | | | | | | | | | | | | | |
| B3 |0|0|BA|B2|B9|B1|B8|B0|0|0|BA|B2|B9|B1|B8|B0|
+------------------+---------------------+---------------------+
The modes are indicated by bit-coding, as shown above. The particular bit or bits, if set to logical "1", indicate that mode to be available. The 2 most significant bits should be set to logical "0". The use of type B3 transactions is discussed in section 3B.
2B.5 Type B4 (information separator) transactions
Type B4 (information separator) transactions have fixed length of 2 bytes, as shown below. First byte defines transaction type as B4, and second byte defines the separator.
+------------------+------------------+
| Type | End Code |
| | | |R| |
| | |G|E| |
| B4 | F|R|C|U|
| | I|O|O|N|
| | L|U|R|I|
| | E|P|D|T|
+------------------+------------------+
The following separator codes are assigned:
Code Meaning
Hex Octal
01 001 Unit separator
03 003 Record separator
07 007 Group separator
0F 017 File separator
Files, groups, records, and units may be data blocks that a user defines to be so. The only restriction is that of the hierarchical relationship File>Groups>Records>Units (where '>' means 'contains'). Thus a file separator marks not only the end of file, but also the end of group, record, and unit. These separators may provide a convenient "logical" separation of data at the data transfer level. Their use is governed by the applications protocol.
2B.6 Type B5 (error codes) transactions
Type B5 (error codes) transactions have a fixed length of 3 bytes, as shown below. First byte defines transaction type as B5, second byte indicates an error code, and third byte may indicate the sequence number on which error occurred.
+------------------+-------------------+-----------------+
| Type | Error Code | Sequence # |
| | | |
| B5 | | |
+------------------+-------------------+-----------------+
The following error codes are assigned:
Error Code Meaning
Hex Octal
00 000 Undefined error
01 001 Out of sync. (type code other
than B0 through BF).
02 002 Broken sequence (the sequence #
field contains the first expected
but not received sequence number).
03 003 Illegal DLE sequence (other than
DLE DLE or DLE ETX).
B0 260
through through The transaction type (indicated by
BF 277 by error code) is not implemented.
The error code transaction is defined only for the purpose of error control. DTP does not require the receiver of an error code to take any recovery action. The receiver may discard the error code transaction. In addition, DTP does not require that sequence numbers be remembered or transmitted.
2B.7 Type B6 (abort) transactions
Type B6 (abort) transactions have a fixed length of 2 bytes, as shown below. First byte defines transaction type as B6, and second byte defines the abort function.
+-------------------+--------------------+
| Type | Function |
| | | | |R| |
| | | |G|E| |
| | |F|R|C|U|
| | |I|O|O|N|
| | |L|U|R|I|
| | |E|P|D|T|
+-------------------+--------------------+
The following abort codes are assigned:
Abort Code Meaning
Hex Octal
00 000 Abort preceding transaction
01 001 Abort preceding unit
02 002 Abort preceding record
07 007 Abort preceding group
0F 017 Abort preceding file
DTP does not require the receiver of an abort to take specific action, therefore sender should not necessarily make any assumptions. The manner in which abort is handled is to be specified by higher-level applications protocols.
2B.8 Type B7 (NoOp) transactions
Type B7 (NoOp) transactions are one byte long, and indicate no operation. These may be useful as fillers when byte size used for network connections is other than 8-bits.