Skip to main content

Third Level Description

Notation​

There is no standard notation for describing system calls, which initiate and close connections or cause data to be sent, so the following ad hoc notation will be used.

Init​

Init (local = l, foreign = f, size = s)

causes the local Host to attempt to establish a connection between socket l at the local Host and socket f, with a byte size of s for the connection.

  • l is a 32 bit local socket number,
  • f is a 40 bit foreign socket number, the high-order eight bits of which specify the foreign Host, and
  • s is an eight bit non-zero byte size.

The sum of l and f must be odd.

Listen​

Listen (local = l, size = s)

causes the local Host to wait for a request for connection to local socket l with byte size s. The process will be woken when a connection is established. The parameters l and s are the same as for Init.

Send​

Send (socket = l, data = d)

The data named by d is sent over the connection attached to local socket l. l must be a send socket attached to a connection. d is the name of a data area.

Receive​

Receive (socket = l, data = d)

The receive side counterpart to send.

Close​

Close (socket = l)

Any connection currently attached to local socket l is closed.

A Family of ICPs​

Briefly, a server process at a site attaches a well-advertised send socket L and listens. A user process initiates connection to L from its receive socket U. The byte size for this connection is 32. The server process then transmits a 32-bit even number S and closes the connection. The 32-bit number S and its successor, S+1, are the socket numbers the server will use. The final steps are for sockets S and S+1 at the server site to be connected to sockets U+3 and U+2 respectively at the user site.

Using the notation, the server executes the following sequence:

   Listen (socket = L, size = 32)
[Wait until a user connects]
Send (socket = L, data = S)
Close (socket = L)
Init (local = S, foreign = U+3, size = Bu)
Init (local = S+1, foreign = U+2, size = Bs)

The user executes the following:

   Init (local = U, foreign = L, size = 32)
Receive (socket = U, data = S)
Optional Close (socket = U)
Listen or Init (local = U+3, foreign = S, size = Bu)
Listen or Init (local = U+2, foreign = S+1, size = Bs)

Note that L is a send socket (odd), while S and U are receive sockets (even). Where L, S, or U are used as values of local, they are 32-bit numbers; where they are values of foreign, they are 40-bit numbers. The parameters Bs and Bu are the byte sizes to be sent by the server and user, respectively. If the user side declines to close socket U, then it must be handled automatically by the second level (see the Second Level Description).

Examination of the above sequences reveals that an ICP is characterized by three numbers L, Bs, and Bu, and must meet the restrictions that

  • (a) L is a send socket,
  • (b) Bs and Bu are legal byte sizes, and
  • (c) for each L there is only one pair of associated byte sizes.

This last restriction prevents two district services from being available through the same socket and distinguished only by the byte sizes.