1. Introduction
Applicability
This specification is intended for those implementations which desire to use the PPP encapsulation over high speed private point-to-point links, such as intra-campus single-mode fiber which may already be installed and unused. Because the PPP encapsulation has relatively low overhead, it is anticipated that significantly higher throughput can be attained compared to other SONET/SDH payload mappings, at a significantly lower cost for line termination equipment.
PPP was designed as a standard method of communicating over point-to-point links. Initial deployment has been over short local lines, leased lines, and plain-old-telephone-service (POTS) using modems. As new packet services and higher speed lines are introduced, PPP is easily deployed in these environments as well.
This specification is primarily concerned with the use of the PPP encapsulation over SONET/SDH links. Since SONET/SDH is by definition a point-to-point circuit, PPP is well suited to use over these links.
The Synchronous Optical Network (SONET) [3] is an octet-synchronous multiplex scheme that defines a family of standard rates and formats. Despite the name, it is not limited to optical links. Electrical specifications have been defined for single-mode fiber, multi-mode fiber, and CATV 75 ohm coaxial cable. The transmission rates are integral multiples of 51.840 Mbps, which may be used to carry T3/E3 bit-synchronous signals. The allowed multiples are currently specified as
STS-1 51.840 STS-18 933.120
STS-3 155.520 STS-24 1,244.160
STS-9 466.560 STS-36 1,866.240
STS-12 622.080 STS-48 2,488.320
The CCITT Synchronous Digital Heirarchy (SDH) defines a subset of SONET transmission rates beginning at 155.520 Mbps [5].
SONET SDH equivalent
STS-3c STM-1
STS-12c STM-4
STS-48c STM-16