Skip to main content

2.3. Callback

2.3. Callback​

Description​

This Configuration Option provides a method for an implementation to request a dial-up peer to call back. This option might be used for many diverse purposes, such as savings on toll charges. When Callback is successfully negotiated, and authentication is complete, the Authentication phase proceeds directly to the Termination phase, and the link is disconnected. Then, the peer re-establishes the link, without negotiating Callback. A peer which agrees to this option SHOULD request the Authentication-Protocol Configuration Option. The user information learned during authentication can be used to determine the user location, or to limit a user to certain locations, or merely to determine whom to bill for the service. Authentication SHOULD be requested in turn by the implementation when it is called back, if mutual authentication is desired. A summary of the Callback Option format is shown below. The fields are transmitted from left to right. 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1

   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Type | Length | Operation | Message ...
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

Type​

13

Length​

= 3

Operation​

The Operation field is one octet and indicates the contents of the Message field. 0 location is determined by user authentication 1 Dialing string, the format and contents of which assumes configuration knowledge of the specific device which is making the callback. 2 Location identifier, which may or may not be human readable, to be used together with the authentication information for a database lookup to determine the callback location. 3 E.164 number. 4 Distinguished name.

Message​

The Message field is zero or more octets, and its general contents are determined by the Operation field. The actual format of the information is site or application specific, and a robust implementation SHOULD support the field as undistinguished octets. The size is determined from the Length field. It is intended that only an authorized user will have correct site specific information to make use of the Callback. The codification of the range of allowed usage of this field is outside the scope of this specification.