Skip to main content

Some Real-World Examples

Although the ideas outlined so far seem fairly straightforward, it is surprisingly easy to find real-world examples that pose a challenge in interpretation. In the Xerox/DEC/Intel Ethernet [5, 6], for example, the concept of a network attachment point is elusive, because it collapses into the node name. A node can physical attach to an Ethernet anywhere along it; the node brings with it a 48-bit unique identifier that its interfaces watches for in packets passing by. This identifier should probably be thought of as the name of a network attachment point, even though the physical point of attachment can be anywhere. At the same time, one can adopt a policy that the node will supply from its own memory the 48-bit identifier that is to be used by the Ethernet interface, so a second, equally reasonable, view (likely to be taken elsewhere in the network in interpreting the meaning of these identifiers) is that this 48-bit identifier is the name of the node itself. From a binding perspective this way of using the Ethernet binds the node name and the network attachment point name to be the same 48-bit unique identifier.

This permanent binding of node name to attachment point name has several network management advantages:

  • a node can be moved from one physical location to another without changing any network records.
  • one level of binding tables is omitted. This advantage is particularly noticeable in implementing internetwork routing.
  • a node that is attached to two Ethernets can present the same attachment point name to both networks, which simplifies communication among internet routers and alternate path finding.

But permanent binding also produces a curiosity if is happens that one wants one node to connect to two attachment points on the same Ethernet. The curiosity arises because the only way to make the second attachment point independently addressable by others is to allow the node to use two different 48-bit identifiers, which means that some other network records (the ones that interpret the ID to be a node name) will likely be fooled into believing that there are not one, but two nodes. To avoid this confusion, the same 48-bit identifier could be used in both attachment points, but then there will be no way intentionally to direct a message to one rather than the other. One way or another, the permanent binding of attachment point name to node name has made some function harder to accomplish, though the overall effect of the advantages probably outweighs the lost function in this case.

For another example, the ARPANET NCP protocol provides character string names that appear, from their mnemonics, to be node names or service names, but in fact they are the names of network attachment points [6]. Thus the character string name RADC-Multics is the name of the network attachment point at ARPANET IMP 18, port 0, so reattaching the node (a Honeywell 68/80 computer) to another network attachment point requires either that the users learn a new name for the service or else a change of tables in all other nodes. Changing tables superficially appears to be what rebinding is all about, but the need to change more than one table is the tip-off that something deeper is going on. What is actually happening is the change of the permanent name of the network attachment point. We can see this more clearly by noting that a parallel attachment of that Honeywell 68/80 to a second ARPANET port would be achievable only by assigning a second character string identity; this requirement emphasizes that the name is really of the attachment point, not the node. Unfortunately, because of their mnemonic value, the ARPANET NCP name mnemonics are often thought of as service names. Thus one expects that that the Rome Air Development Center Multics service is operated on the node reached by the name RADC-Multics. This particular assumption doesn't produce any surprises. But any one of the four Digital PDP-10 computers at Bolt, Beranek and Newman can accept mail for any of the others, as can the groups of PDP-10's at the USC Information Sciences Institute, and at the Massachusetts Institute of Technology. If the node to which ones tries to send mail is down, the customer must realize that the same service is available by asking for a different node, using what appears to be a different service name. The need for a customer to realize that he must give a different name to get the same service comes about because in the ARPANET the name is not of a service that is bound to a node that is bound to an attachment point, but rather it is directly the name of an attachment point.

Finally, confusion can arise because the three conceptually distinct binding services (service name resolution, node name location, and route dispensing) may not be mechanically distinct. There is usually suggested only one identifiable service, a "name server". The name server starts with a service name and returns a list of network attachment points that can provide that service. It thereby performs both the first and second conceptual binding services, though it may leave to the customer the final choice of which attachment point to use. Path choice may be accomplished by a distributed routing algorithm that provides the final binding service without anyone noticing it.