Skip to main content

4. Mapping of the MODULE-COMPLIANCE macro

The MODULE-COMPLIANCE macro is used to convey a minimum set of requirements with respect to implementation of one or more MIB modules. It should be noted that the expansion of the MODULE-COMPLIANCE macro is something which conceptually happens during implementation and not during run-time.

A requirement on all "standard" MIB modules is that a corresponding MODULE-COMPLIANCE specification is also defined, either in the same information module or in a companion information module.

4.1. Mapping of the STATUS clause​

The STATUS clause, which must be present, indicates whether this definition is current or historic.

The values "current", and "obsolete" are self-explanatory. The "deprecated" value indicates that that object is obsolete, but that an implementor may wish to support that object to foster interoperability with older implementations.

4.2. Mapping of the DESCRIPTION clause​

The DESCRIPTION clause, which must be present, contains a textual definition of this compliance statement and should embody any information which would otherwise be communicated in any ASN.1 commentary annotations associated with the statement.

4.3. Mapping of the REFERENCE clause​

The REFERENCE clause, which need not be present, contains a textual cross-reference to a compliance statement defined in some other information module.

4.4. Mapping of the MODULE clause​

The MODULE clause, which must be present, is repeatedly used to name each MIB module for which compliance requirements are being specified. Each MIB module is named by its module name, and optionally, by its associated OBJECT IDENTIFIER as well. The module name can be omitted when the MODULE-COMPLIANCE invocation occurs inside a MIB module, to refer to the encompassing MIB module.

4.4.1. Mapping of the MANDATORY-GROUPS clause​

The MANDATORY-GROUPS clause, which need not be present, names the one or more groups within the correspondent MIB module which are unconditionally mandatory for implementation. If a SNMPv2 entity acting in an agent role claims compliance to the MIB module, then it must implement each and every object within each conformance group listed. That is, if a SNMPv2 entity returns a noSuchObject exception in response to a management protocol get operation [5] for any object within any mandatory conformance group for every MIB view, then that SNMPv2 entity is not a conformant implementation of the MIB module.

4.4.2. Mapping of the GROUP clause​

The GROUP clause which need not be present, is repeatedly used to name each MIB group which is conditionally mandatory or unconditionally optional for compliance to the MIB module. A MIB group named in a GROUP clause must be absent from the correspondent MANDATORY-GROUPS clause.

Conditionally mandatory groups include those which are mandatory only if a particular protocol is implemented, or only if another group is implemented. A GROUP clause's DESCRIPTION specifies the conditions under which the group is conditionally mandatory.

A MIB group which is named in neither a MANDATORY-GROUPS clause nor a GROUP clause, is unconditionally optional for compliance to the MIB module.

4.4.3. Mapping of the OBJECT clause​

The OBJECT clause which need not be present, is repeatedly used to name each MIB object for which compliance has a refined requirement with respect to the MIB module definition. The MIB object must be present in one of the conformance groups named in the correspondent MANDATORY-GROUPS clause or GROUP clauses.

4.4.3.1. Mapping of the SYNTAX clause​

The SYNTAX clause, which need not be present, is used to provide a refined SYNTAX for the object named in the correspondent OBJECT clause. Note that if this clause and a WRITE-SYNTAX clause are both present, then this clause only applies when instances of the object named in the correspondent OBJECT clause are read.

Consult Section 10 of [2] for more information on refined syntax.

4.4.3.2. Mapping of the WRITE-SYNTAX clause​

The WRITE-SYNTAX clause, which need not be present, is used to provide a refined SYNTAX for the object named in the correspondent OBJECT clause when instances of that object are written.

Consult Section 10 of [2] for more information on refined syntax.

4.4.3.3. Mapping of the MIN-ACCESS clause​

The MIN-ACCESS clause, which need not be present, is used to define the minimal level of access for the object named in the correspondent OBJECT clause. If this clause is absent, the minimal level of access is the same as the maximal level specified in the correspondent invocation of the OBJECT-TYPE macro. If present, this clause must not specify a greater level of access than is specified in the correspondent invocation of the OBJECT-TYPE macro.

The level of access for certain types of objects is fixed according to their syntax definition. These types are: conceptual tables and rows, auxiliary objects, and objects with the syntax of Counter32, Counter64, or certain types of textual conventions (e.g., RowStatus [6]). A MIN-ACCESS clause should not be present for such objects.

An implementation is compliant if the level of access it provides is greater or equal to the minimal level in the MODULE-COMPLIANCE macro and less or equal to the maximal level in the OBJECT-TYPE macro.

4.4.3.4. Mapping of the DESCRIPTION clause​

The DESCRIPTION clause must be present for each use of the GROUP or OBJECT clause. For an OBJECT clause, it contains a textual description of the refined compliance requirement. For a GROUP clause, it contains a textual description of the conditions under which the group is conditionally mandatory or unconditionally optional.

4.5. Mapping of the MODULE-COMPLIANCE value​

The value of an invocation of the MODULE-COMPLIANCE macro is an OBJECT IDENTIFIER. As such, this value may be authoritatively used when referring to the compliance statement embodied by that invocation of the macro.

4.6. Usage Example​

Consider how a compliance statement might be included at the end of the MIB-II document [3], assuming that conformance groups were defined therein:

mibIICompliances
OBJECT IDENTIFIER ::= { mibIIConformance 1 }
mibIIGroups OBJECT IDENTIFIER ::= { mibIIConformance 2 }

mibIICompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMPv2 entities
residing on systems which implement the Internet
suite of protocols."
MODULE -- compliance to the containing MIB module
MANDATORY-GROUPS { systemGroup, snmpGroup }

GROUP interfacesGroup
DESCRIPTION
"The interfaces group is mandatory for systems
with network interfaces."

GROUP ipGroup
DESCRIPTION
"The ip group is mandatory for systems which
implement IP."

GROUP icmpGroup
DESCRIPTION
"The icmp group is mandatory for systems which
implement ICMP."

GROUP tcpGroup
DESCRIPTION
"The tcp group is mandatory for systems which
implement TCP."
OBJECT tcpConnState
MIN-ACCESS read-only
DESCRIPTION
"A compliant system need not allow
write-access to this object."

GROUP udpGroup

DESCRIPTION
"The udp group is mandatory for systems which
implement UDP."

GROUP egpGroup
DESCRIPTION
"The egp group is mandatory for systems which
implement EGP."

::= { mibIICompliances 1 }

According to this invocation, to claim alignment with the compliance statement named

     { mibIICompliances 1 }

a system must implement RFC1213's systemGroup and snmpGroup conformance groups. If the system implements any network interfaces, then RFC1213's interfacesGroup conformance group must be implemented. Further, if the system implements any of the IP, ICMP, TCP, UDP, or EGP protocols, then the correspondent conformance group in RFC1213 must be implemented, if compliance is to be claimed. Finally, although RFC1213 specifies that it makes "protocol sense" for the tcpConnState object to be writable, this specification allows the system to permit only read-only access and still claim compliance.