2. Objects
Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. Objects in the MIB are defined using the subset of Abstract Syntax Notation One (ASN.1) [6] defined in the SMI. In particular, each object has a name, a syntax, and an encoding. The name is an object identifier, an administratively assigned name, which specifies an object type. The object type together with an object instance serves to uniquely identify a specific instantiation of the object. For human convenience, we often use a textual string, termed the OBJECT DESCRIPTOR, to also refer to the object type.
The syntax of an object type defines the abstract data structure corresponding to that object type. The ASN.1 language is used for this purpose. However, the SMI [1] purposely restricts the ASN.1 constructs which may be used. These restrictions are explicitly made for simplicity.
The encoding of an object type is simply how that object type is represented using the object type's syntax. Implicitly tied to the notion of an object type's syntax and encoding is how the object type is represented when being transmitted on the network.
The SMI specifies the use of the basic encoding rules of ASN.1 [7], subject to the additional requirements imposed by the SNMP.
2.1. Format of Definitions
Section 4 contains contains the specification of all object types contained in this MIB module. The object types are defined using the conventions defined in the SMI, as amended by the extensions specified in STD 16, RFC 1212 [2].
2.2. Changes from RFC 1232
The changes from RFC 1232 are the following:
- This MIB module contains three groups: DS1 Near End Group which is mandatory, DS1 Far End Group which is optional, and the Fractional Table, which is optional.
- The Far End Group is a new group and contains statistics that are collected from the far end DS1 interface. The Far End Group may only be implemented by DS1 systems that use the facilities data link to exchange this information - both T1.403 and PUB 54016 define ways to exchange this information over data links; vendors may use other proprietary means to do this on various link types.
- ds1CSUIndex has been renamed dsx1LineIndex. This object is the identifier of a DS1 Interface on a device. On a CSU, a single DS1 data stream will cross two DS1 interfaces, which have separate dsx1LineIndex values.
- ds1Index has been renamed dsx1IfIndex. This value for this object is equal to the value of ifIndex from the Interfaces table of MIB II (STD 17, RFC 1213).
- an object has been added (dsx1TransmitClockSource) to indicate the source of transmit clock.
- The ACCESS for objects in the dsx1ConfigTable has been set to read-write for items that are configurable.
- Description of test configurations has changed. A new object has been added called dsx1LoopbackConfig, which better describes the loopback capabilities of a DS1 interface on a device.
- The description of line alarm status has changed. A new object has been added called dsx1LineStatus. This object better describes the status (e.g., failure state and loopback state) of a DS1 interface.
- All Counters have been changed to Gauges.
- Information about how applications might use the zero code suppression have been removed; only the actual line coding algorithm is described. For clarity the object was thus renamed to dsx1LineCoding.
- A Line Errored Seconds object has been added to all near end tables and the count of Bipolar Violations (BPVs) was changed to a count of Line Code Violations (LCVs).
- Bursty Errored Seconds (a.k.a., Errored Seconds Type B) and Degraded Minutes objects have been added to all near end tables.
- The Coding Violation error event is now referred to as a Path Coding Violation (PCV) Error Event.