Skip to main content

4. Overview

These objects are used when the particular media being used to realize an interface is a DS3 interface. At present, this applies to these values of the ifType variable in the Internet-standard MIB:

ds3 (30)

The definitions contained herein are based on the DS3 specifications in ANSI T1.102-1987, ANSI T1.107-1988, and ANSI T1.404-1989 [9,10,11].

4.1. Binding between Interfaces and CSUs​

Each agent which resides on a host which uses DS3 interfaces is required to assign a small, positive integer uniquely to each CSU. This is known as the "CSUIndex", and is used to distinguish between different CSUs attached to a node. The CSUIndex is also used as the "key" when accessing tabular information about DS3 interfaces.

The ds3Index column of the DS3 Configuration table relates each CSU to its corresponding interface in the Internet-standard MIB.

4.2. Objectives of this MIB Module​

There are numerous things that could be included in a MIB for DS3 signals: the management of multiplexors, CSUs, DSUs, and the like. The intent of this document is to facilitate the common management of CSUs, both in-chassis and external via proxy. As such, a design decision was made up front to very closely align the MIB with the set of objects that can generally be read from CSUs that are currently deployed.

4.3. DS3 Terminology​

The terminology used in this document to describe error conditions on a DS3 circuit as monitored by a DS3 CSU are from the ANSI T1M1.3/90 draft standard [12].

Out of Frame (OOF) event: An OOF event is detected when any three or more errors in sixteen or fewer consecutive F-bits occur within a DS3 M-frame. An OOF event is cleared when reframe occurs.

Loss of Signal (LOS): This state is declared upon observing 175 +/- 75 contiguous pulse positions with no pulses of either positive or negative polarity.

Coding Violation (CV): For all DS3 applications, a coding violation is a P-bit Parity Error event. A P-bit Parity Error event is the occurrence of a received P-bit code on the DS3 M-frame that is not identical to the corresponding locally-calculated code. For C-Bit Parity applications, it is also the occurrence of a received CP-Bit parity violation. For SYNTRAN applications, it is also the occurrence of a received CRC-9 code that is not identical to the corresponding locally calculated code.

Bipolar Violation (BPV): A bipolar violation, for B3ZS-coded signals, is the occurrence of a received bipolar violation that is not part of a zero-substitution code. For B3ZS-coded signals, a bipolar violation may also include other error patterns such as: three or more consecutive zeros and incorrect parity.

Errored Seconds (ES): An ES is a second with one or more Coding Violation OR one or more Out of Frame events OR an AIS.

Severely Errored Seconds (SES): A SES is a second with 44 or more Coding Violations OR one or more Out of Frame events OR an AIS.

Severely Errored Framing Seconds (SEFS): A SEFS is a second with one or more Out of Frame events.

Unavailable Seconds (UAS): UAS are calculated by counting the number of seconds that the CSU is in the Unavailable signal state (i.e., declared a Red Alarm or a Yellow Alarm), including the initial 10 seconds to enter the state but not including the 10 seconds to exit the state.

Note that any second that may be counted as an UAS may not be counted as an ES or a SES. Since the 10 SESs that comprise the transition from the available to unavailable signal state may also be counted as ESs and SESs previous to entering the state, these three counters are adjusted so that any second counted during this transition is then subtracted. The 10 seconds in the transition from unavailable to available may be counted as ESs.

A special case exists when the 10 or more second period crosses the 900 second statistics window boundary, as the foregoing description implies that the SES and UAS counters must be adjusted when the Unavailable Signal State is entered. Clearly, successive GETs of the affected ds3IntervalSES and ds3IntervalUAS objects will return differing values if the first GET occurs during the first few seconds of the window. This is viewed as an unavoidable side-effect of selecting the presently defined managed objects as a basis for this memo.

Yellow Alarm: The Yellow Alarm is declared after detecting the Yellow Signal. See ANSI T1.107-1989 [10].

Red Alarm: The Red Alarm is declared after detecting a Loss of Signal, a Loss of Frame (a persistent OOF event), or an Alarm Indication Signal, see [10] for at least 2-10 seconds. The Red Alarm is cleared at the onset of 10 consecutive seconds with no SES.

Circuit Identifier: This is a character string specified by the circuit vendor, and is useful when communicating with the vendor during the troubleshooting process.