4. Overview
These objects are used when the particular media being used to realize an interface is a DS1 physical interface. At present, this applies to these values of the ifType variable in the Internet-standard MIB:
ds1 (18)
e1 (19)
The definitions contained herein are based on the AT&T T-1 specifications and Extended Superframe (ESF) format [9, 10], the latter of which conforms to proposed ANSI specifications [14, 15]. The various T1 and E1 line disciplines are similar enough that separate MIBs are unwarranted, although there are some differences. For example, Loss of Frame is defined more rigorously in the ESF specification than in the D4 specification, but it is defined in both.
4.1. Binding between Interfaces and CSUs
It should be noted that it is possible to multiplex multiple bit streams onto a single DS1 physical interface (CSU), realizing multiple interfaces from the perspective of the Internet-standard MIB. It is also possible to concatenate physical interfaces to provide a single logical interface. As such, it is important to be able to distinguish between the indices used to identify the CSUs attached to a node and the indices used to identify an interface (in the MIB sense) attached to a node.
Each agent which resides on a host which uses DS1 physical interfaces is required to assign a small, positive integer uniquely to each CSU. This is known as the "CSUIndex", and is used to distinguish between different CSUs attached to a node. The CSUIndex is also used as the "key" when accessing tabular information about DS1 physical interfaces.
The potentially many-to-one binding between CSU indices and the ifIndex value assigned to each MIB interface are defined in the ds1ConfigTable table defined in the next section.
4.2. Objectives of this MIB Module
There are numerous things that could be included in a MIB for DS1 Interfaces: the management of multiplexors, CSUs, DSUs, and the like. The intent of this document is to facilitate the common management of CSUs, both in-chassis and external via proxy. As such, a design decision was made up front to very closely align the MIB with the set of objects that can generally be read from CSUs that are currently deployed, which is to say ESF CSUs conforming to AT&T specifications. However, by simple generalization of these objects, the MIB is also made applicable to D4 and G.704 devices.
To meet a requirement not easily satisfied in other places, there is one additional group present, the Fractional DS1 group. This is intended to facilitate the use of fractional DS1 devices (i.e., devices which utilize a subset of the 8 bit channels available in the frame) over the managed CSUs.
4.3. DS1 Terminology
The terminology used in this document to describe error conditions on a T1 or E1 circuit monitored by a CSU are from references [10], [11], [14], and [15].
Out of Frame event: An Out of Frame event is declared when the receiver detects two or more framing-bit errors within a 3 millisecond period, or two or more errors out of five or less consecutive framing-bits. At this time, the framer enters the Out of Frame State, and starts searching for a correct framing pattern. The Out of Frame state ends when reframe occurs.
Loss of Signal: This event is declared upon observing 175 +/- 75 contiguous pulse positions with no pulses of either positive or negative polarity (also called keep alive).
Code Violation Error Event: A Code Violation Error Event is the occurrence of a received Cyclic Redundancy Check code that is not identical to the corresponding locally-calculated code.
Bipolar Violation: A Bipolar Violation, for B8ZS-coded signals, is the occurrence of a received bipolar violation that is not part of a zero-substitution code. It also includes other error patterns such as: eight or more consecutive zeros and incorrect parity.
Errored Seconds: An Errored Second is a second with one or more Code Violation Error Events OR one or more Out of Frame events. In D4 and G.704 section 2.1.3.2 (eg, G.704 which does not implement the CRC), the presence of Bipolar Violations also triggers an Errored Second.
Severely Errored Seconds: A Severely Errored Second is a second with 320 or more Code Violation Error Events OR one or more Out of Frame events.
Severely Errored Framing Second: An Severely Errored Framing Second is a second with one or more Out of Frame events.
Unavailable Signal State: This state is declared at the onset of 10 consecutive Severely Errored Seconds. It is cleared at the onset of 10 consecutive seconds with no Severely Errored Second.
Unavailable Seconds: Unavailable Seconds are calculated by counting the number of seconds that the CSU is in the Unavailable Signal State, including the initial 10 seconds to enter the state but not including the 10 seconds to exit the state.
Note that any second that may be counted as an Unavailable Second may not be counted as an Errored Second, a Severely Errored Second. Since the 10 Severely Errored Seconds that comprise the transition from the available to Unavailable Signal State may also be counted as Errored Seconds, and Severely Errored Seconds previous to entering the state, these three counters are adjusted so that any second counted during this transition is then subtracted. The 10 seconds in the transition from unavailable to available may be counted as Errored Seconds.
A special case exists when the 10 or more second period crosses the 900 second statistics window boundary, as the foregoing description implies that the Severely Errored Second and Unavailable Second counters must be adjusted when the Unavailable Signal State is entered. Clearly, successive GETs of the affected ds1IntervalSES and ds1IntervalUAS objects will return differing values if the first GET occurs during the first few seconds of the window. This is viewed as an unavoidable side-effect of selecting the presently deployed AT&T objects as a basis for this memo.
Yellow Alarm: A Yellow Alarm is declared because of an incoming Yellow Signal from the far-end. In effect, the circuit is declared to be a one way link.
Red Alarm: A Red Alarm is declared because of an incoming Loss of Signal, Loss of Framing, Alarm Indication Signal. After a Red Alarm is declared, the device sends a Yellow Signal to the far-end. The far-end, when receives the Yellow Signal, declares a Yellow Alarm.
Circuit Identifier: This is a character string specified by the circuit vendor, and is useful when communicating with the vendor during the troubleshooting process.