5. 5250 Data Stream Enhancements
This section is intended to be used as an addendum to the IBM 5250 Information Display System, Functions Reference Manual. Described here are enhancements to the 5250 data stream which are not yet documented in the current version of that manual. The current version of that manual at the time of this writing has the IBM publication number SA21-9247-6. Also described in this section are corrections to erroneous information contained in SA21-9247-6. Listed below are the specific corrections and enhancements, with an approximate page number reference to the above manual.
5.1 Errors or Inconsistencies in SA21-9247-6
The Insert Cursor (IC) order on pages 2-136 and 2-137 is incorrectly listed with a value of Hex 03; the correct value is Hex 13.
On page 2-137, the listed "Restrictions" for the Insert Cursor, Repeat to Address, and Set Buffer Address orders should be updated to describe how Row and Column values must be valid for the current display screen size (either 24 x 80 or 27 x 132).
5.2 Enhancements to Existing 5250 Data Stream Commands/Orders
A new flag is added to the second byte of the Control Character on page 2-40. This flag is used to specify whether the cursor should be moved or not moved at the end of the Write to Display processing. Bit 1 of the second byte, which was previously reserved, will now be used for this flag. If bit 1 is a 0, the cursor continues to be moved to the system IC address on a Lock-to-Unlock keyboard transition. If bit 1 is a 1, the cursor is not moved.
A new Field Control Word (FCW) will be added on page 2-65 to indicate an entry field contains transparent data. This means the entry field contents are sent from the display screen directly to the host at read time with no formatting. Therefore, an entry field can contain any values (Hex 00 to Hex FF). A transparent field is indicated by a Hex 84xx FCW, where xx is any value. Note: unpredictable results will occur if a field is defined as both signed numeric and a transparent field.
The Read Immediate, Read Input Fields, and Read MDT Fields commands have been enhanced to include support for transparent fields (page 2-5). If a transparent FCW is found for an input field, the field data is not formatted (for example, nulls are not converted to blanks).
The restriction listed for the Set Buffer Address (SBA) order (page 2-138) on the column address equal to zero is no longer always the case. A reference to Start of Field (SF) row 1/column 1 field support should be made. A note should be added in SF to describe Row 1/Column 1 field support. A Row 1/Column 1 field is defined by a SBA of row 1/column 0, followed by an SF. For a Row 1/Column 1 input field, the first input-capable position is row 1/column 1. If the SF defines an input field, the screen attribute is not allowed to be nondisplay. Writing of the screen attribute is suppressed for a Row 1/Column 1 field and the attribute discarded.
5.3 New 5250 Data Stream Commands/Orders
The Read MDT Fields Alternate input command has been added. It is the same as the Read MDT Fields command except:
- The command is indicated by a X'82'
- Leading and embedded nulls within the field remain as nulls
The Read MDT Fields Immediate Alternate input command has been added. It is the same as the Read MDT Fields Alternate command except:
- The command is indicated by a X'83'
- The command is an immediate read command like Read Immediate; therefore, no control characters follow the command byte, field data is returned immediately, and the aid code is X'00'.
The Move Cursor order (MC) has been added (page 2-137). The MC order moves the cursor to the location specified by the two bytes following the order. Byte 1 gives the row address and byte 2 gives the column address. The MC order is useful when the cursor is to be moved without affecting the system IC address. The MC order is unaffected by the Write to Display control character values including the "Leave Cursor" flag (CC1 bit 1). If more than one MC or IC are found in the data stream, the cursor will move to the address specified in the last MC or IC.
Restrictions:
A parameter error will be posted when:
- There are fewer then two bytes following the order.
- The row address is zero or greater than the number of rows on the display screen.
- The column address is zero or greater than the number of columns on the display screen.
Format:
Move Cursor Order Byte 1 Byte 2
X'14' Row Address Column Address
Results:
The address specified by the MC order is used to move the cursor when the Write to Display is completed.
The Transparent Data order (TD) has been added (page 2-137). The TD order is followed by two length bytes and transparent data. The transparent data is written to the display screen at the current display address; any values (Hex 00 to Hex FF) are allowed in the transparent data. All length values are valid as long as the end of the display screen is not overwritten.
Restrictions:
A parameter error will be posted when:
- There are fewer then two bytes following the order.
- There are fewer bytes in the data stream then specified in the length field.
- Attempting to write beyond the end of the display screen.
Format:
TD Order Bytes 1 and 2 Bytes 3 to ?
X'10' Length of transparent Transparent data
data (not counting
length bytes)
Results:
The transparent data is written to the display.
The Query command is a new input command (page 2-5) and is used by the server to obtain information on the functional capabilities of the client 5250 display. When the client receives a Query command, the client sends a Query Reply describing its capabilities back to the server.
The Query command must follow an Escape ('04'X) and Write Structured Field command ('F3'X). The format of the Query command is as follows:
Byte Value Description
====== ======= ========================
0-1 X'0005' Length of command
2 X'D9' Command Class
3 X'70' Command Type - Query
4 X'00' Flag Byte
Bit 0: B'0' - Query Command
Bit 1-7: - Reserved (set to zero)
The format of the Query Reply is as follows:
Byte Value Description
===== ======== ===================================
0-1 X'0000' Cursor Row/Column (set to zero)
2 X'88' Inbound Write Structured Field Aid
3-4 X'003A' Length of Query Reply
5 X'D9' Command Class
6 X'70' Command Type - Query
7 X'80' Flag Byte
Bit 0: B'1' - Query Reply
Bit 1-7: - Reserved (set to zero)
8-9 Controller Hardware Class
X'0001' - Local Twinax Controller
X'0061' - Local ASCII Controller
X'0101' - SDLC/X.21/X.25 Twinax Controller
(5394 emulating a 5294)
X'0103' - SDLC/X.21/X.25 Twinax Controller (5394)
X'0200' - PC DOS non-DBCS WSF
X'0300' - OS/2 non-DBCS WSF
X'0400' - PC DOS DBCS WSF
X'0500' - OS/2 DBCS WSF
X'0600' - Other WSF or any other 5250 Emulator
10-12 Controller Code Level
X'010300' - For example, Version 1 Rel 3.0
13-28 X'00' Reserved (set to zero)
29 Device Type
X'01' - 5250 Display or 5250 Emulation
30-33 C'cccc' Device Type (e.g. 3180 for 3180 Mod 2)
34-36 C'ccc' Device Model (e.g. 002 for 3180 Mod 2)
37 Keyboard ID
X'02' - Standard Keyboard
X'82' - G Keyboard
38 X'00' Extended Keyboard ID
39 X'00' Reserved
40-43 X'xxxxxxxx' Display Serial Number
44-45 Maximum number of input fields
X'0100' - Typically = 256 input fields
46-48 X'00' Reserved (set to zero)
49-53 Controller/Display Capability
Bit 0-1: B'00' - No Row 1/Col 1 support
B'01' - Row 1/Col 1 support
Bit 2: B'0' - No Read MDT Alternate Command support
B'1' - Read MDT Alternate Command support
Bit 3: B'0' - Display does not have PA1/PA2 support
B'1' - Display does have PA1/PA2 support
Bit 4: B'0' - Display does not have PA3 support
B'1' - Display does have PA3 support
Bit 5: B'0' - Display does not have Cursor Select support
B'1' - Display does have Cursor Select support
Bit 6: B'0' - Display does not have Move Cursor Order support
B'1' - Display does have Move Cursor Order support
Bit 7: B'0' - No Read MDT Immediate Alt Command support
B'1' - Read MDT Immediate Alt Command support
50
Bit 0-3: B'0001' - 24 x 80 Screen Size
B'0011' - Capable of 24 x 80 and 27 x 132
Bit 4: B'0' - No light pen support
B'1' - Light pen support
Bit 5: B'0' - No Mag Stripe Reader support
B'1' - Mag Stripe Reader support
Bit 6-7: B'00' - Mono display
B'01' - 5292/3179 style color, including color PCs
51 X'00' - Reserved
52
Bit 0-2: B'000' - No Double Byte Character Set (DBCS)
capability
B'001' - Presentation screen DBCS capability only
Bit 3-7: B'00000' - Reserved
53
Bit 0-2: B'000' - No graphics capability
B'001' - 5292-2 style graphics
Bit 3-7: B'00000' - Reserved
54-60 X'00' Reserved (set to zero)