Skip to main content

Preface

The subroutines described in this document have been implemented at UCSB and make the Network (via the NCP) accessible to Fortran programs executing in the 360/75. They are callable from within any Fortran main program or subroutine compiled at UCSB.

A set of assembly-language written subprograms is provided to facilitate the sue of the Network by FORTRAN programmers. They serve as an interface between the user and the Network Control Program (NCP), which supervises all Network operations at this site.

A concept fundamental to FORTRAN Network operations is that of a completion code variable. Associated with each socket that is not in the closed state is a unique variable, called a completion code variable. This variable serves two purposes: it identifies the local socket referenced, and upon completion of the operation it contains a completion code to indicate the outcome of the operation to the programmer. It may be used at any time for any purpose other than network operations. Its value at the beginning of a Network operation is immaterial; rather it is the variable itself that is important. In all Network operations, whenever a completion code variable is called for, the only acceptable type variable is INTERGER*4.

In general, the subprograms will initiate the operation, and enter the WAIT state (consume no CPU time) until notified by the NCP of the completion of the operation. For such operations, the programmer supplies a time limit, of type INTERGER*4, which specifies, in tenths of a second, the maximum length of time the subprogram is to wait for the operation to complete. If this time limit is exceeded, a completion code is supplied to indicate the error; and control is returned to the calling program, with the operation still pending.

In those operations requiring a socket to be specified by its socket identifier, the following format is used. The identifier is specified as a INTEGER*4 array with at least two elements, or an element of such an array. The first element specified is taken to be the site number, and the next element the socket number. A socket number may have any value, positive, negative, or zero. Since negative numbers are represented internally in two's complement form, for the purposes of the gender of a socket, a socket number is even for odd according to whether its absolute value is even or odd, respectively.

Following is a description of each subprogram, its function and calling sequence.