Skip to main content

8. Subnetwork Dependent Functions

The Subnetwork Dependent Functions mask the characteristics of the different kinds of Subnetworks from the Subnetwork Independent Routeing Functions. The only two types of circuits the Subnetwork Independent Functions recognise are broadcast and general topology.

The Subnetwork Dependent Functions include:

  • The use of the ISO 8473 Subnetwork Dependent Convergence Functions (SNDCF) so that this protocol may transmit and receive PDUs over the same subnetwork types, using the same techniques, as does ISO 8473.
  • Co-ordination with the operation of the ESIS protocol (ISO 9542) in order to determine the Network layer addresses (and on Broadcast subnetworks, the subnetwork points of attachment) and identities (End System or Intermediate System) of all adjacent neighbours. This information is held in the Adjacency data base. It is used to construct Link State PDUs.
  • The exchange of IIH PDUs. While it is possible for an Intermediate System to identify that it has an Intermediate System neighbour by the receipt of an ISO 9542 ISH PDU, there is no provision within ISO 9542 to indicate whether the neighbour is a Level 1 or a Level 2 Intermediate System. Specific PDUs (LAN Level 1, LAN Level 2 and Point to point IIH PDUs) are defined to convey this information.

8.1. Multi-destination Circuits on ISs at a Domain Boundary​

Routeing information (e.g. Link State PDUs) is not exchanged across a routeing domain boundary. All routeing information relating to a circuit connected to another routeing domain is therefore entered via the Reachable Address managed objects. This information is disseminated to the rest of the routeing domain via Link State PDUs as described in 7.3.3.2. This has the effect of causing NPDUs destined for NSAPs which are included in the addressPrefixes of the Reachable Addresses to be relayed to that Intermediate System at the domain boundary. On receipt of such an NPDU the Intermediate system shall forward it onto the appropriate circuit, based on its own Link State information. However in the case of multi-destination subnetworks (such as an ISO 8208 subnetwork using Dynamic Assignment, a broadcast subnetwork, or a connectionless subnetwork) it is necessary to ascertain additional subnetwork dependent addressing information in order to forward the NPDU to a suitable SNPA. (This may be the target End system or an Intermediate system within the other domain.)

In general the SNPA address to which an NPDU is to be forwarded can be derived from the destination NSAP of the NPDU. It may be possible to perform some algorithmic manipulation of the NSAP address in order to derive the SNPA address. However there may be some NSAPs where

this is not possible. In these cases it is necessary to have pre-configured information relating an address prefix to a particular SNPA address.

This is achieved by additional information contained in the Reachable Address managed object. The mappingType attribute may be specified as Manual, in which case a particular SNPA address or set of SNPA addresses is specified in the SNPA Address characteristic. Alternatively the name of an SNPA address extraction algorithm may be specified.

8.2. Point to Point Subnetworks​

This clause describes the identification of neighbours on both point to point links and Static circuits.

The IS shall operate the ISO 9542 protocol, shall be able to receive ISO 9542 ISH PDUs from other ISs, and shall store the information so obtained in the adjacency database.

8.2.1. Receipt of ESH PDUs Database of End Systems​

An IS shall enter an End system into the adjacency database when an ESH PDU is received on a circuit. If an ESH PDU is received on the same circuit, but with a different NSAP address, the new address shall be added to the adjacency, with a separate timer. A single ESH PDU may contain more than one NSAP address. When a new data link address or NSAP address is added to the adjacency database, the IS shall generate an adjacencyStateChange (Up) notification on that adjacency.

The IS shall set a timer for the value of Holding Time in the received ESH PDU. If another ESH PDU is not received from the ES before that timer expires, the ES shall be purged from the database, provided that the Subnetwork Independent Functions associated with initialising the adjacency have been completed. Otherwise the IS shall clear the adjacency as soon as those functions are completed.

When the adjacency is cleared, the Subnetwork Independent Functions shall be informed of an adjacencyStateChange (Down) notification, and the adjacency can be re-used after the Subnetwork Independent Functions associated with bringing down the adjacency have been completed.

8.2.2. Receiving ISH PDUs by an Intermediate System​

On receipt of an ISH PDU by an Intermediate System, the IS shall create an adjacency (with state Initialising and neighbourSystemType Unknown), if one does not already exist, and then perform the following actions:.

  1. If the Adjacency state is Up and the ID portion of the NET field in the ISH PDU does not match the neighbourID of the adjacency then the IS shall:
  2. generate an adjacencyStateChange (Down) notification;
  3. delete the adjacency; and
  4. create a new adjacency with:
  5. state set to Initialising, and
  6. neighbourSystemType set to Unknown.
  7. perform the following actions..
  8. If the Adjacency state is Initialising, and the neighbourSystemType status is Intermediate System, the ISH PDU shall be ignored.
  9. If the Adjacency state is Initialising and the neighbourSystemType status is not Intermediate System, a point to point IIH PDU shall be transmitted as described in 8.2.3.
  10. The neighbourSystemType status shall be set to Intermediate System indicating that the neighbour is an Intermediate system, but the type (L1 or L2) is, as yet, unknown.

8.2.3. Sending Point to Point IIH PDUs​

An IS shall send Point-to-Point IIH PDUs on those Point-to-Point circuits whose externalDomain attribute is set False. The IIH shall be constructed and transmitted as follows:

  1. The Circuit Type field shall be set according to Table 3.
  2. The Local Circuit ID field shall be set to a value assigned by this Intermediate system when the circuit is created. This value shall be unique among all the circuits of this Intermediate system.
  3. The first Point to Point IIH PDU (i.e. that transmitted as a result of receiving an ISH PDU, rather than as a result of timer expiration) shall be padded (with trailing PAD options containing arbitrary valued octets) so that the SNSDU containing the IIH PDU has a length of at least maxsize - 1 octets77The minimum length of PAD which may be added is 2 octets, since that is the size of the option header. Where possible the PDU should be padded to maxsize, but if the PDU length is maxsize- 1 octets no padding is possible (or required). where maxsize is the maximum of
1)dataLinkBlocksize
2)originating

L1

LSP

Buf

fer

Size
3)originatingL2LSPBufferSize

This is done to ensure that an adjacency will only be formed between systems which are capable of exchanging PDUs of length up to maxsize octets. In the absence of this check, it would be possible for an adjacency to exist with a lower maximum block size, with

the result that some LSPs and SNPs (i.e. those longer than this maximum, but less than maxsize) would not be exchanged.

NOTE - It is necessary for the manager to ensure that the value of dataLinkBlocksize on a circuit which will be used to form an Intermediate system to Intermediate system adjacency is set to a value greater than or equal to the maximum of the LSPBufferSize characteristics listed above. If this is not done, the adjacency will fail to initialise. It is not possible to enforce this requirement, since it is not known until initialisation time whether or not the neighbour on the circuit will be an End system or an Intermediate system. An End system adjacency may operate with a lower value for dataLinkBlocksize.

  1. If the value of the circuitTransmitPassword for the circuit is non-null, then the IS shall include the Authentication Information field in the transmitted IIH PDU, indicating an Authentication Type of Password and containing the circuitTransmitPassword as the authentication value.

8.2.4. Receiving Point to Point IIH PDUs​

8.2.4.1. PDU Acceptance Tests​

On receipt of a Point-to-Point IIH PDU, perform the following PDU acceptance tests:

  1. If the IIH PDU was received over a circuit whose externalDomain attribute is set True, the IS shall discard the PDU.
  2. If the ID Length field of the PDU is not equal to the value of the IS's routeingDomainIDLength, the PDU shall be discarded and an iDFieldLengthMismatch notification generated.
  3. If the set of circuitReceivePasswords for this circuit is non-null, then perform the following tests:
  4. If the PDU does not contain the Authentication Information field then the PDU shall be discarded and an authenticationFailure notification generated.
  5. If the PDU contains the Authentication Information field, but the Authentication Type is not equal to Password, then the PDU shall be accepted unless the IS implements the authentica tiion procedure indicated by the Authentication

Type. In this case whether the IS accepts or ignores the PDU is outside the scope of this International Standard. 3. Otherwise, the IS shall compare the password in the received PDU with the passwords in the set of circuitReceivePasswords for the circuit on which the PDU was received. If the value in the PDU matches any of these passwords, the IS shall accept the PDU for further processing. If the value in the PDU does not match any of the circuitReceivePasswords, then the IS shall ignore the PDU and generate an authenticationFailure notification.

8.2.4.2. IIH PDU Processing​

When a Point to Point IIH PDU is received by an Intermediate system, the area addresses of the two Intermediate Systems shall be compared to ascertain the validity of the adjacency. If the two Intermediate systems have an area address in common, the adjacency is valid for all combinations of Intermediate system types (except where a Level 1 Intermediate system is connected to a Level 2 Intermediate system with manualL2OnlyMode set True). However, if they have no area address in common, the adjacency is only valid if both Intermediate systems are Level 2, and the IS shall mark the adjacency as Level 2 Only. This is described in more detail below.

On receipt of a Point to Point IIH PDU, each of the area addresses from the PDU shall be compared with the set of area addresses in the manual

Area

Addresses attribute.
  1. If a match is detected between any pair the following actions are taken.
  2. If the local system is of iSType L1
Inter

mediate

Sys

tem the IS shall perform the action indicated
by Table 4.
  1. If the local system is of iSType L2
Intermediate

System and the Circuit manualL2OnlyMode
has the value False, the IS shall perform the ac
tion indicated by Table 5.
  1. If the local system is of iSType L2
Intermediate

System and the Circuit manualL2OnlyMode
has the value True, the IS shall perform the ac
tion indicated by Table 6.
  1. If a no match is detected between any pair, the following actions shall be performed.
  2. If the local system is of iSType L1
Inter

mediate

Sys

tem and the adjacency is not in state Up,
the IS shall delete the adjacency (if any) and gen
erate an initialisationFailure (Area Mismatch)
notification.
  1. If the local system is of iSType L1
Inter

mediate

Sys

tem and the adjacency is in state Up, the IS
shall delete the adjacency and generate an adja
cencyStateChange (Down Area Mismatch)
notification .
  1. If the local system is of iSType L2

Intermediate System the IS shall perform the action indicated by Table 7 (irrespective of the value of manualL2OnlyMode for this circuit).

c)If the action taken is Up, as detailed in the tables referenced above, the IS shall compare the Source ID field of the PDU with the local systemID.

1)If the local Intermediate system has the higher Source ID, the IS shall set the Circuit CircuitID status to the concatenation of the local systemID and the Local Circuit ID (as sent in the Local Circuit ID field of point to point IIH PDUs from this Intermediate System) of this circuit.

2)If the remote Intermediate system has the higher Source ID, the IS shall set the Circuit CircuitID status to the concatenation of the remote system's Source ID (from the Source ID field of the PDU), and the remote system's Local Circuit ID (from the Local Circuit ID field of the PDU).

3)If the two source IDs are the same (i.e. the system is initialising to itself), the local systemID is used.

NOTE The circuitID status is not used to generate the Local Circuit ID to be sent in the Local Circuit ID field of IIH PDUs transmitted by this Intermediate system. The Local Circuit ID value is assigned once, when the circuit is created and is not subsequently changed.

d)If the action taken is Accept and the new value computed for the circuitID is different from that in the existing adjacency, the IS shall

1)generate an adjacencyStateChange(Down) notification, and

2)delete the adjacency.

e)If the action taken is Up or Accept the IS shall

1)copy the Adjacency neighbourAreas entries from the PDU,

2)set the holdingTimer to the value of the Holding Time from the PDU, and

3)set the neighbourSystemID to the value of the Source ID from the PDU.

8.2.5. Monitoring Point-to-point Adjacencies​

The IS shall keep a holding time (adjacency holding Timer) for the point-to-point adjacency. The value of the holding Timer shall be set to the Holding Time as reported in the Holding Timer field of the Pt-Pt IIH PDU. If a neighbour is not heard from in that time, the IS shall

a)purge it from the database; and

b)generate an adjacencyStateChange (Down) notification.

8.3. ISO 8208 Subnetworks​

8.3.1. Network Layer Protocols​

The way in which the underlying service assumed by ISO 8473 is provided for ISO 8208 subnetworks is described in clause 8 of ISO 8473. This defines a set of Subnetwork Dependent Convergence Functions (SNDCFs) that relate the service provided by specific individual ISO-standard subnetworks to the abstract underlying service defined in clause 5.5 of ISO 8473. In particular 8.4.3 describes the Subnetwork Dependent Convergence Functions used with ISO 8208 Subnetworks.

8.3.2. SVC Establishment​

8.3.2.1. Use of ISO 8473 Subnetwork Dependent Convergence Functions​

SVCs shall be established according to the procedures defined in the ISO 8208 Subnetwork Dependent Convergence Functions of ISO 8473 (this may be on system management action or on arrival of data depending on the type of circuit). The Call Request shall contain a Protocol Discriminator specifying ISO 8473 in the first octet of Call Userdata. In the case of a static circuit, an SVC shall be established only upon system management action. The IS shall use neighbourSNPAAddress as the called SNPA address. In the case of a DA circuit, the call establishment procedures are initiated by the arrival of traffic for the circuit.

8.3.2.2. Dynamically Assigned Circuits​

A dynamically assigned circuit has multiple adjacencies, and can therefore establish SVCs to multiple SNPAs. In general the SNPA address to which a call is to be established can be derived from the NSAP to which an NPDU is to be forwarded. In the case where all the NSAPs accessible over the ISO 8208 subnetwork have IDIs which are their SNPA addresses, the correct SNPA can be ascertained by extracting the IDI. However there may be some NSAPs, which it is required to reach over the ISO 8208 subnetwork, whose IDI does not correspond to the SNPA address of their point of attachment to the ISO 8208 subnetwork. The IDI may refer to some other SNPA address which is sub-optimally connected to the target NSAP (or not even connected at all), or the IDP may not contain an X.121 address at all (e.g. ISO DCC scheme). In these cases the IS shall have pre-configured information relating an IDP (or address prefix) to a particular SNPA address to call.

This is achieved, as described in 8.1, by additional information contained in the Reachable Address managed object. The address extraction algorithm may be specified to extract the IDI portion where the IDI is the required X.121 address. An example of a set of Reachable Addresses is shown in Table 8.

Table 8 - Example of address prefixesAddress Prefix

39
37 aaaaa
37
*
37 D
SNPA Address
123X
B
Y
Extract X.121 SNPA address
R, S, T

This is interpreted as follows:

a)For the ISO DCC prefix 39 123, call the SNPA address X.

b)For the X.121 IDI address prefix 37 aaaaa, don't call aaaaa, but call B instead.

c)For all IDPs based on SNPAs with DNIC D (i.e. with address prefix 37 D), call the address Y (which would probably be a gateway to a subnetwork with DNIC D).

d)For any other X.121 IDI (i.e. address prefix 37) call the SNPA whose address is used as the IDI.

e)Anything else (* in table 8) call one of the SNPA addresses R, S or T. These would typically be the SNPA addresses of Level 2 Intermediate Systems through which any other addresses could potentially be reached.

NOTE - If a DA circuit is defined with a reachable address prefix which includes the addresses reachable over a DCM or STATIC circuit, the cost(s) for the DA circuit must be greater than those of the STATIC circuit. If this is not the case, the DA circuit may be used to establish a call to the remote SNPA supporting the STATIC circuit, which would then (wrongly) assume it was the STATIC circuit.

8.3.2.3. Initiating Calls (Level 2 Intermediate Systems)​

When an NPDU is to be forwarded on a dynamically assigned circuit, for destination NSAP address D, the IS shall:

a)Calculate D's subnetwork address, either as explicitly stated in the circuit database, or as extracted from the IDP.

1)If this system is an ES and there is an entry in the RedirectCache or ReversePathCache for D, use the subnetwork address in the cache entry.

2)If this system is an ES or Level 2 Intermediate system, and the address matches one of the listed reachable address prefixes (including *, if present), the subnetwork address is that specified according to the mappingType attribute (either Manual, indicating that the set of addresses in the sNPAAddresses attribute of that Reachable Address are to be used, or Algorithm, indicating that it is to be extracted from the IDP using the specified algorithm). If multiple SNPA addresses are specified, and there is already an adjacency up to one of those SNPA addresses, then choose that subnetwork address, otherwise choose the subnetwork address with the oldest timestamp as described in 8.3.2.4.

3)If the address does not match one of the listed reachable address prefixes (and there is no * entry), invoke the ISO 8473 Discard PDU function.

b)Scan the adjacencies for one already open to D's subnetwork address (i.e. reserveTimer has not yet expired). If one is found, transmit the NPDU on that adjacency.

c)If no adjacency has a call established to the required subnetwork address, but there is a free adjacency, attempt to establish the call using that subnetwork address.

d)If there is no free adjacency invoke the ISO 8473 Discard PDU function.

NOTE Where possible, when an adjacency is reserved (when an SVC has been cleared as a result of the idleTimer expiring, but the reserveTimer has not yet expired), resources within the subnetwork service provider should be reserved, in order to minimise the probability that the adjacency will not be able to initiate a call when required.

8.3.2.4. Call Attempt Failures​

The Reachable Address managed objects may contain a set of SNPA addresses, each of which has an associated time-stamp. The time-stamps shall be initialised to infinitely old.

Some of the SNPAs in this set may be unreachable. If a call attempt fails to one of the SNPA addresses listed, the IS shall mark that entry in the list with the time of the latest failed attempt. When an SNPA address is to be chosen from the list, the IS shall choose the one with the oldest time-stamp , unless the oldest time-stamp is more recent than recallTimer. If the oldest time-stamp is more recent than recallTimer, all SNPAs in the set shall be assumed temporarily unreachable and no call attempt is made. The IS shall instead invoke the ISO 8473 Discard PDU function.

When attempting to establish a connection to a single specific subnetwork address (not through one of a set of SNPA addresses), if a call attempt to a particular SNPA address, A, fails for any reason, the IS shall invoke the ISO 8473 Discard PDU function. Additionally the adjacency on which the call attempt was placed shall be placed in Failed state, and the recall timer set. Until it expires, the IS shall not attempt call establishment for future NPDUs to be forwarded over subnetwork address A, but instead the IS shall invoke the ISO 8473 Discard PDU function. When the recall timer expires, the IS shall free the adjacency for calls to a different destination or retry attempts to subnetwork address A.

NOTE - If an implementation can store the knowledge of SNPA addresses that have failed along with the time since the attempt was made in a location other than the adjacency on which the call was attempted, then that adjacency can be used for other calls.

8.3.3. Reverse Path Forwarding on DA Circuits​

Where a subdomain is attached to a Connection-oriented subnetwork by two or more SNPAs, the IDP for the addresses within the subdomain may be chosen to be constructed from the address of one of the points of attachment. (It need not be. The whole subdomain could be multi-homed by using both SNPA addresses, or some other IDP could be chosen; e.g. ISO DCC.) Traffic to the subdomain from some other SNPA will cause a call to be established to the SNPA corresponding to the IDP of the addresses in the subdomain. Traffic from the subdomain may use either of the SNPAs depending on the routeing decisions made by the subdomain. This is illustrated in the diagram below (figure 5).

Figure 5 - B.xB.yC.zISO 8208 SubnetworkBACExample for reverse path
forwarding

The subdomain is attached to the connection-oriented subnetwork via SNPAs A and B. The addresses on the subdomain are constructed using the SNPA address of B as the IDI. If traffic for C.z is sent from B.x, a call will be established from A to C. The reverse traffic from C.z to B.x will cause another call to be established from C to B. Thus two SVCs have been established where only one is required.

This problem is prevented by the local system retaining a cache (known as the ReversePathCache) of NSAP addresses from which traffic has been received over each adjacency. When it has traffic to forward over the connection-oriented subnetwork, the IS shall it first check to see if the destination NSAP is in the cache of any of its adjacencies, and if so forwards the traffic over that adjacency. An NSAP shall only be added to the cache when the remote SNPA address of the adjacency over which it is received differs from the SNPA address to be called which would be generated by checking against the Circuit Reachable Addresses managed objects. If the cache is full, the IS shall overwrite the least recently used entry. The ReversePathCache, if implemented, shall have a size of at least one entry. The IS shall purge the cache when the adjacency is taken down (i.e. when the reserve timer expires).

8.3.4. Use of ISO 9542 on ISO 8208 subnetworks​

STATIC and DA circuits are equivalent to point to point links, and as such permit the operation of ISO 9542 as described for point to point links in 8.2.

For DA circuits, it is impractical to use ISO 9542 to obtain configuration information, such as the location of Intermediate systems, since this would require calls to be established to all possible SNPA addresses.

The IS shall not send ISO 9542 ISH PDUs on a DA circuit. The IS shall take no action on receipt of an ESH PDU or ISH PDU, and the circuit shall complete initialisation without waiting for their arrival.

The IS shall not send Point to point IIH PDU on DA circuits. The IS shall ignore receipt of a point-point IIH PDU. (This would only occur if a STATIC or DA circuit became erroneously connected to an SVC being used for a DA circuit.)

8.3.5. Interactions with the Update Process​

A dynamically assigned circuit contains a list of <reachable address prefix, cost, SNPA address> tuples. Also, each dynamically assigned circuit has a specified call establishment cost measured by call

Estab

lish

ment

Met

rick (where k indexes the four defined metrics). The call establishment cost is always an internal metric, and is therefore directly comparable with the reachable address metric only if the reachable address metric is also internal. When the circuit is enabled, the Subnetwork Dependent functions in an Intermediate system shall report (to the Update Process) adjacency cost change events for all address prefixes in the circuit Reachable Address managed object, together with the Reachable address metrick + Deltak increment. If reachable address metrick is internal, then Deltak = callEstab-lishmentMetrick. If reachable address metrick is external, then Deltak = 0. This causes this information to be included in subsequently generated LSPs as described in 7.3.3.2. Routeing PDUs (LSPs and Sequence number PDUs) shall not be sent on dynamically assigned circuits. NOTE - In the following sub-clauses, it is assumed that the Reachable Addresses referenced are only those which have been enabled (i.e. that have state On), and whose parent circuit is also in state On.

8.3.5.1. Adjacency Creation​

After an SVC to SNPA address D is successfully established and a new adjacency created for it (whether it was initiated by the local or the remote system), if callEstab-lishmentMetrickIncrement is greater than 0, the IS shall scan the circuit Reachable Address managed objects for all addressPrefixes listed with D as (one of) the sNPAAddress(es). For Reachable Addresses with mappingType Algorithm, the IS shall construct an implied address prefix88i.e. some address prefix which matches the addressPrefix of the Reachable Address, and which would generate the SNPA Address D when the extraction algorithm is applied

from the actual remote SNPA address D and the address extraction algorithm. The IS shall generate an Adjacency cost change event for each such address prefix (both actual and implied) with the Reachable Address metrick (without the added callEstab-lishmentMetrickIncrement). This causes information that those address prefixes are reachable with the lower cost to be included in subsequently generated LSPs. The effect of this is to encourage the use of already established SVCs where possible.

8.3.5.2. Adjacency Deletion​

When the adjacency with sNPAAddress D is freed (Reserve Timer has expired, or the adjacency is deleted by System Management action) then if callEstab-lishmentMetrickIncrement is greater than 0, the IS shall scan the Circuit Reachable Address managed objects for all those with mappingType Manual and (one of) their sNPAAddresses equal to D. The IS shall generate Adjacency cost change events to the Update Process for all such address prefixes with the Reachable Address metrick + Deltak increment (where Deltak is the same as defined above). For Reachable Addresses with mappingType X.121 for which it is possible to construct an implied address prefix as above, the IS shall generate an adjacencyStateChange notification for that implied prefix. A cost change event shall only be generated when the count of the number of subnetwork addresses which have an established SVC changes between 1 and 0.

8.3.5.3. Circuit Call Establishment Increment Change​

On a dynamically assigned circuit, when system management changes the Circuit callEstab-lishmentMetrickIncrement for that circuit, the IS shall generate adjacency cost change events for all address prefixes affected by the change (i.e. those for which calls are not currently established). The IS shall scan all the Reachable Address managed objects of that Circuit. If the Reachable Address has mappingType X.121, the IS shall generate an adjacency cost change event for that name with the Reachable Address metrick + the new value of Deltak. If (based on the new value of callEstab-lishmentMetrickIncrement) the Reachable Address has mappingType Manual, the IS shall scan all the Adjacencies of the Circuit for an Adjacency with sNPAAddress equal to (one of) the sNPAAddresses of that Reachable Address. If no such adjacency is found the IS shall generate an adjacency cost change event for that name with the Reachable Address metrick + the new value of Deltak (based on the new value of callEstlishmentMetrickIncrement).

8.3.5.4. Reachable Address Cost Change​

When the metrick characteristic of a Reachable Address in state On is changed by system management, the IS shall generate cost change events to the Update Process to reflect this change. If the Reachable Address has mappingType Manual, the IS shall scan all the Adjacencies of the Circuit for an Adjacency with sNPAAddress equal to (one of) the sNPAAddresses of that Reachable Address. If one or more such adjacencies are found, the IS shall generate an adjacency cost change event for that name with the new Reachable Address metrick. If no such adjacency is found the IS shall generate an adjacency cost change event for that name with the new Reachable Address metrick. If the Reachable Address has mappingType X.121, the IS shall generate an adjacency cost change event for that name with the new Reachable Address metrick + Deltak (based on the new value of callEstab-lishmentMetrickIncrement). In addition, for all Adjacencies of the Circuit with an sNPAAddress for which an implied address prefix can be generated for this Reachable Address, the IS shall generate an adjacency cost change event for that implied address prefix and the new Reachable Address metrick.

8.3.5.5. Disabling a Reachable Address​

When a Reachable Address managed object is disabled via management action, the IS shall generate an Adjacency down event to the Update Process for the name of that Reachable Address and also for any implied prefixes associated with that Reachable Address.

8.3.5.6. Enabling a Reachable Address​

When a Reachable Address is enabled via system management action, the IS shall generate Adjacency cost change events as described for Reachable Address cost change in 8.3.5.4 above.

8.4. Broadcast Subnetworks​

8.4.1. Broadcast Subnetwork IIH PDUs​

All Intermediate systems on broadcast circuits (both Level 1 and Level 2) shall transmit LAN IIH PDUs as described in 8.4.3. Level 1 Intermediate systems shall transmit only Level 1 LAN IIH PDUs. Level 2 Intermediate Systems on circuits with manualL2OnlyMode set to the value True, shall transmit only Level 2 LAN IIH PDUs. Level 2 Intermediate systems on circuits with manualL2OnlyMode set to the value False, shall transmit both. Level n LAN IIH PDUs contain the transmitting Intermediate system's ID, holding timer, Level n Priority and manualAreaAddresses, plus a list containing the lANAddresses of all the adjacencies of neighbourSystemType Ln Intermediate System (in state Initialising or Up) on this circuit. LAN IIH PDUs shall be padded (with trailing PAD options containing arbitrary valued octets) so that the SNSDU containing the IIH PDU has a length of at least maxsize- 1 octets99The minimum length of PAD which may be added is 2 octets, since that is the size of the option header. Where possible the PDU should be padded to maxsize, but if the PDU length is maxsize- 1 octets no padding is possible (or required). where maxsize for Level 1 IIH PDUs is the maximum of

  • dataLinkBlocksize
  • originatingL1LSPBufferSize

and for Level 2 IIH PDUs is the maximum of

  • dataLinkBlocksize
  • originatingL2LSPBufferSize

This is done to ensure that an adjacency will only be formed between systems which are capable of exchanging PDUs of length up to maxsize octets. In the absence of this check, it would be possible for an adjacency to exist with a lower maximum block size, with the result that some LSPs and SNPs (i.e. those longer than this maximum, but less than maxsize) would not be exchanged. NOTE - An example of a topology where this could occur is one where an extended LAN is constructed from LAN segments with different maximum block sizes. If, as a result of mis-configuration or some dynamic reconfiguration, a path exists between two Intermediate systems on separate LAN segments having a large maximum block size, which involves transit of a LAN segment with a smaller maximum block size, loss of larger PDUs will occur if the Intermediate systems continue to use the larger maximum block size. It is better to refuse to bring up the adjacency in these circumstances. Level 1 Intermediate systems shall transmit Level 1 LAN IIH PDUs to the multi-destination address AllL1ISs, and also listen on that address. They shall also listen for ESH PDUs on the multi-destination address AllIntermediateSystems. The list of neighbour Intermediate systems shall contain only Level 1 Intermediate Systems within the same area. (i.e. Adjacencies of neighbourSystemType L1 Intermediate System.) Level 2 Only Intermediate systems (i.e. Level 2 Intermediate systems which have the Circuit manualL2OnlyMode characteristic set to the value True) shall transmit Level 2 LAN IIH PDUs to the multi-destination address AllL2ISs, and also listen on that address. The list of neighbour Intermediate systems shall contain only Level 2 Intermediate systems. (i.e. Adjacencies of neighbourSystemType L2 Intermediate System.) Level 2 Intermediate systems (with manualL2OnlyMode False) shall perform both of the above actions. Separate Level 1 and Level 2 LAN IIH PDUs shall be sent to the multi-destination addresses AllL1ISs and AllL2ISs describing the neighbour Intermediate systems for Level 1 and Level 2 respectively. Separate adjacencies shall be created by the receipt of Level 1 and Level 2 LAN IIH PDUs.

8.4.1.1. IIH PDU Acceptance Tests​

On receipt of a Broadcast IIH PDU, perform the following PDU acceptance tests:

  1. If the IIH PDU was received over a circuit whose externalDomain attribute is True, the IS shall discard the PDU.
  2. If the ID Length field of the PDU is not equal to the value of the IS's routeingDomainIDLength, the PDU shall be discarded and an iDFieldLengthMismatch notification generated.
  3. If the set of circuitReceivePasswords for this circuit is non-null, then perform the following tests:
    1. If the PDU does not contain the Authentication Information field then the PDU shall be discarded and an authenticationFailure notification generated.

2)If the PDU contains the Authentication Information field, but the Authentication Type is not equal to Password, then the PDU shall be accepted unless the IS implements the authentication procedure indicated by the Authentication Type. In this case whether the IS accepts or ignores the PDU is outside the scope of this International Standard.

3)Otherwise, the IS shall compare the password in the received PDU with the passwords in the set of circuitReceivePasswords for the circuit on which the PDU was received. If the value in the PDU matches any of these passwords, the IS shall accept the PDU for further processing. If the value in the PDU does not match any of the circuitReceivePasswords, then the IS shall ignore the PDU and generate an authenticationFailure notification.

8.4.1.2. Receipt of Level 1 IIH PDUs​

On receipt of a Level 1 LAN IIH PDU on the multi-destination address AllL1ISs, the IS shall compare each of the area addresses, from the received IIH PDU with the set of area addresses in the manual Area Addresses characteristic. If a match is not found between any pair (i.e. the local and remote system have no area address in common), the IS shall reject the adjacency and generate an initialisationFailure (area mismatch) notification. Otherwise (a match is found) the IS shall accept the adjacency and set the Adjacency neighbourSystemType to L1 Intermediate System.

8.4.1.3. Receipt of Level 2 IIH PDUs​

On receipt of a Level 2 LAN IIH PDU on the multi-destination address AllL2ISs, the IS shall accept the adjacency, and set the Adjacency neighbourSystemType to L2 Intermediate System.

8.4.1.4. Existing Adjacencies​

When a Level n LAN IIH PDU (Level 1 or Level 2) is received from an Intermediate system for which there is already an adjacency with

  1. the Adjacency lANAddress equal to the MAC Source address of the PDU, and
  2. the Adjacency neighbourSystemID equal to the Source ID field from the PDU and
  3. the neighbourSystemType equal to Ln Intermediate System,

the IS shall update the holding timer, LAN Priority and neighbourAreas according to the values in the PDU.

8.4.1.5. New Adjacencies​

When

  1. a Level n LAN IIH PDU (Level 1 or Level 2) is received (from Intermediate system R), and
  2. there is no adjacency for which the Adjacency lANAddress is equal to the MAC Source address of the PDU; and
  3. the Adjacency neighbourSystemID is equal to the Source ID field from the PDU, and
  4. neighbourSystemType is Ln Intermediate System,

the IS shall create a new adjacency. However, if there is insufficient space in the adjacency database, to permit the creation of a new adjacency the IS shall instead perform the actions described in 8.4.2.

The IS shall

  1. set neighbourSystemType status to Ln Intermediate System (where n is the level of the IIH PDU),
  2. set the holding timer, LAN Priority, neighbourID and neighbourAreas according to the values in the PDU., and
  3. set the lANAddress according to the MAC source address of the PDU.

The IS shall set the state of the adjacency to initialising, until it is known that the communication between this system and the source of the PDU (R) is two-way. However R shall be included in future Level n LAN IIH PDUs transmitted by this system.

When R reports this circuit's lANAddress in its Level n LAN IIH PDUs, the IS shall

  1. set the adjacency's state to Up, and
  2. generate an adjacencyStateChange (Up) notification.

The IS shall keep a separate Holding Time (Adjacency holding Timer) for each Ln Intermediate System adjacency. The value of holding Timer shall be set to the Holding Time as reported in the Holding Timer field of the Level n LAN IIH PDUs. If a neighbour is not heard from in that time, the IS shall

  1. purge it from the database; and
  2. generate an adjacencyStateChange (Down) notification.

If a Level n LAN IIH PDU is received from neighbour N, and this system's lANAddress is no longer in N's IIH PDU, the IS shall

  1. set the adjacency's state to initialising, and
  2. generate an adjacencyStateChange (Down) notification.

8.4.2. Insufficient Space in Adjacency Database​

If an IS needs to create a new Intermediate system adjacency, but there is insufficient space in the adjacency database, the adjacency of neighbourSystemType Ln Intermediate System with lowest lANPriority (or if more than one adjacency has the lowest priority, the adjacency with the lowest lANAddress, from among those with the lowest priority) shall be purged from the database. If the new adjacency would have the lowest priority, it shall be ignored, and a rejectedAdjacency notification generated.

If an old adjacency must be purged, the IS shall generate an adjacencyStateChange (Down) notification for that adjacency. After the Subnetwork Independent Functions issue an adjacency down complete, the IS may create a new adjacency.

8.4.3. Transmission of LAN IIH PDUs​

A Level 1 IS shall transmit a Level 1 LAN IIH PDU immediately when any circuit whose externalDomain attribute is False has been enabled. A Level 2 Intermediate System shall transmit a Level 2 LAN IIH PDU. A Level 2 Intermediate System shall also transmit a Level 1 LAN IIH PDU unless the circuit is marked as manualL2OnlyMode True.

The IS shall also transmit a LAN IIH PDU when at least 1 second has transpired since the last transmission of a LAN IIH PDU of the same type on this circuit by this system and:

  1. iSIS Hello Timer seconds have elapsed1010Jitter is applied as described in 10.1. since the last periodic LAN IIH PDU transmission

The Holding Time is set to ISISHoldingMultiplier W iSIS Hello Timer. For a Designated Intermediate System the value of dRISIS Hello Timer1111 In this case jitter is not applied, since it would result in intervals of less than one second. is used instead of iSISHelloTimer. The Holding Time for this PDU shall therefore be set to ISISHoldingMultiplier W dR ISIS Hello Timer seconds. This permits failing Designated Intermediate Systems to be detected more rapidly,

or

  1. the contents of the next IIH PDU to be transmitted would differ from the contents of the previous IIH PDU transmitted by this system, or
  2. this system has determined that it is to become or resign as LAN Designated Intermediate System for that level.

To minimise the possibility of the IIH PDU transmissions of all Intermediate systems on the LAN becoming synchronised, the Hello Time timer shall only be reset when a IIH PDU is transmitted as a result of timer expiration, or on becoming or resigning as Designated Intermediate System.

Where an Intermediate system is transmitting both Level 1 and Level 2 LAN IIH PDUs, it shall maintain a separate timer (separately jittered) for the transmission of the Level 1 and Level 2 IIH PDUs. This avoids correlation between the Level 1 and Level 2 IIH PDUs and allows the reception buffer requirements to be minimised.

If the value of the circuitTransmitPassword for the circuit is non-null, then the IS shall include the Authentication Information field in the transmitted IIH PDU, indicating an Authentication Type of Password and containing the circuitTransmitPassword as the authentication value.

8.4.4. LAN Designated Intermediate Systems​

A LAN Designated Intermediate System is the highest priority Intermediate system in a particular set on the LAN, with numerically highest MAC source lANAddress breaking ties. (See 7.1.5 for how to compare LAN addresses.) There are, in general, two LAN Designated Intermediate Systems on each LAN, namely the LAN Level 1 Designated Intermediate System and the LAN Level 2 Designated Intermediate System. They are elected as follows.

  1. Level 1 Intermediate systems elect the LAN Level 1 Designated Intermediate System.
  2. Level 2 Only Intermediate systems (i.e. Level 2 Intermediate Systems which have the Circuit manual L2 Only Mode characteristic set to the value True) elect the LAN Level 2 Designated Intermediate System.
  3. Level 2 Intermediate systems (with manualL2OnlyMode False) elect both the LAN Level 1 and LAN Level 2 Designated Intermediate Systems.

The set of Intermediate systems to be considered includes the local Intermediate system, together with all Intermediate systems of the appropriate type as follows.

  1. For the LAN Level 1 Designated Intermediate System, it is the set of Intermediate systems from which LAN Level 1 IIH PDUs are received and to which Level 1 adjacencies exist in state Up. When the local system either becomes or resigns as LAN Level 1 Designated Intermediate System, the IS shall generate a lan Level1 Designated Inter mediate Sys tem Change notification. In addition, when it becomes LAN Level 1 Designated Intermediate System, it shall perform the following actions.
    1. Generate and transmit Level 1 pseudonode LSPs using the existing End system configuration.
    2. Purge the Level 1 pseudonode LSPs issued by the previous LAN Level 1 Designated Intermediate System (if any) as described in 7.2.3.
    3. Solicit the new End system configuration as described in 8.4.5.
  2. For the LAN Level 2 Designated Intermediate System, it is the set of Intermediate systems from which LAN Level 2 IIH PDUs are received and to which Level 2 adjacencies exist in state Up. When the local system either becomes or resigns as LAN Level 2 Designated Intermediate System, the IS shall generate a lan Level2 Designated Inter mediate System Change notification. In addition, when it becomes LAN Level 2 Designated Intermediate System, it shall perform the following actions.
    1. Generate and transmit a Level 2 pseudonode LSP.
    2. Purge the Level 2 pseudonode LSPs issued by the previous LAN Level 2 Designated Intermediate System (if any) as described in 7.2.3.

When an Intermediate system resigns as LAN Level 1 or Level 2 Designated Intermediate System it shall perform the actions on Link State PDUs described in 7.2.3.

When the broadcast circuit is enabled on an Intermediate system the IS shall perform the following actions.

  1. Commence sending IIH PDUs with the LAN ID field set to the concatenation of its own systemID and its locally assigned one octet Local Circuit ID.
  2. Solicit the End system configuration as described in 8.4.5.
  3. Start listening for ISO 9542 ISH PDUs and ESH PDUs and acquire adjacencies as appropriate. Do not run the Designated Intermediate System election process.
  4. After waiting iSIS Hello Timer * 2 seconds, run the Level 1 and or the Level 2 Designated Intermediate System election process depending on the Intermediate system type. This shall be run subsequently whenever an IIH PDU is received or transmitted as described in 8.4.3. (For these purposes, the transmission of the system's own IIH PDU is equivalent to receiving it). If there has been no change to the information on which the election is performed since the last time it was run, the previous result can be assumed. The relevant information is 1)the set of Intermediate system adjacency states, 2)the set of Intermediate System priorities (including this system's) and 3)the existence (or otherwise) of at least one Up End system (not including Manual Adjacencies) or Intermediate system adjacency on the circuit.

An Intermediate system shall not declare itself to be a LAN Designated Intermediate system of any type until it has at least one Up End system (not including Manual Adjacencies) or Intermediate system adjacency on the circuit. (This prevents an Intermediate System which has a defective receiver and is incapable of receiving any PDUs from erroneously electing itself LAN Designated Intermediate System.)

The LAN ID field in the LAN IIH PDUs transmitted by this system shall be set to the value of the LAN ID field reported in the LAN IIH PDU (for the appropriate level) received from the system which this system considers to be the Designated Intermediate System. This value shall also be passed to the Update Process, as the pseudonode ID, to enable Link State PDUs to be issued for this system claiming connectivity to the pseudonode.

If this system, as a result of the Designated Intermediate System election process, considers itself to be designated Intermediate System, the LAN ID field shall be set to the concatenation of this system's own system ID and the locally assigned one octet Local Circuit ID.

8.4.5. Soliciting the ES configuration​

When there is a change in the topology or configuration of the LAN (for example the partitioning of a LAN into two segments by the failure of a repeater or bridge), it is desirable for the (new) Designated Intermediate System to acquire the new End system configuration of the LAN as quickly as possible in order that it may generate Link State PDUs which accurately reflect the actual configuration. This is achieved as follows.

When the circuit is enabled, or the Intermediate system detects a change in the set of Intermediate systems on the LAN, or a change in the Designated Intermediate System ID, the IS shall initiate a poll of the ES configuration by performing the following actions.

  1. Delay a random interval between 0 and iSIS

Hello

Timer seconds. (This is to avoid synchronisation with other Intermediate systems which have detected the change.) 2. If (and only if) an Intermediate System had been removed from the set of Intermediate systems on the LAN, reset the entryRemainingTime field in the endSystemIDs adjacency database record of all adjacencies on this circuit to the value (iSIS

Hello

Timer + pollESHelloRate) W HoldingMultiplier or the existing value whichever is the lower. (This causes any End systems which are no longer present on the LAN to be rapidly timed out, but not before they have a chance to respond to the poll.) 3. Transmit HoldingMultiplier ISH PDUs for each NET possessed by the Intermediate system with a Suggested ES Configuration Timer value of poll

ES

Hello

Rate at an interval between them of iSIS

Hello

Timer seconds and a holding time of hello

Timer * HoldingMultiplier. 4. Resume sending ISH PDUs at intervals of hello

Timer seconds with a Suggested ES Configuration Timer value of defaultESHelloTimer.

8.4.6. Receipt of ESH PDUs Database of End Systems​

An IS shall enter an End system into the adjacency database when an ESH PDU is received from a new data link address. If an ESH PDU is received with the same data link address as a current adjacency, but with a different NSAP address, the new address shall be added to the adjacency, with a separate timer. A single ESH PDU may contain more than one NSAP address. When a new data link address or NSAP address is added to the adjacency database, the IS shall generate an adjacencyStateChange (Up) notification on that adjacency.

The IS shall set a timer for the value of the Holding Time field in the received ESH PDU. If another ESH PDU is not received from the ES before that timer expires, the ES shall be purged from the database, provided that the Subnetwork Independent Functions associated with initialising the adjacency have been completed. Otherwise the IS shall clear the adjacency as soon as those functions are completed.

When the adjacency is cleared, the Subnetwork Independent Functions shall be informed of an adjacencyStateChange (Down) notification, and the adjacency can be re-used after the Subnetwork Independent Functions associated with bringing down the adjacency have been completed.