Skip to main content

Specific Recommendations

The committee reached consensus on the following recommendations:

  1. The ECO and ERP command should each be 8 bits long.

  2. The ERR command should be 96 bits long.

  3. Message Data Types should be eliminated. Third-level protocol people may reinstate such a mechanism.

  4. The Cease mechanism should be discontinued.

  5. A new pair of one byte commands RST (reset) and RRP (reset reply) should be added. The RST should be interpreted as a signal to purge the NCP tables of any existing entries which arose from the sending Host. The RRP command should be returned to acknowledge receipt of the RST. The Host sending the RST may proceed after receiving either a RST or a RRP in return. A RST may be returned if the second Host comes up after the first Host.

  6. Although it was suggested at the Urbana meeting that connections should be full-duplex, the committee recommends against this change.

  7. Messages should be an integral number of bytes, and the number of bytes and the byte size should be specified in each message. The marking convention should be abandoned and the padding ignored.

    The number of bytes in the message should be a 16-bit number following the leader. The byte size should be in the next 8-bit field. Two suggestions were generated for the starting point of the text, and these are explained in the next session.

    For flow control purposes, the number of bits in a message is the product of the number of bytes and the byte size. The leader and other fixed format fields are not counted.

  8. The problem of synchronizing the interrupt signal in a console input stream was considered. We consider the console input scanner as a process and note two reasonable implementations: it may either read characters as fast as it can, looking for the interrupt character and throwing away characters if there is no room in the user process' input queue; it may read characters only as fast as the user process can receive them, (or at least has room for them).

    The first implementation guarantees that the interrupt character (e.g., control - C on the PDP-10 10/50) will always be acted on, but requires that the using process interpret the output stream to detect when it is sending too fast. The second implementation avoids overrun but may not allow for sending an interrupt code. Note that in the first case, allocation is always renewed as soon as possible by the console input interpreter; whereas in the second case, allocation is renewed only as the result of acceptance of data by the user process.

    We decided that this is really a third-level protocol matter, viz, use the INS to mean that a special code has been inserted into the input stream. In conjunction with this, create the special code to be put into the input sequence.

    This special code would be network-wide and independent of the particular interrupt character peculiar to the serving system. The scheme for interrupting a serving process is that the using process inserts the serving Host's interrupt sequence, followed by the network special code, and also issue the INS.