メインコンテンツまでスキップ

5. 定義

        RFC1318-MIB DEFINITIONS ::= BEGIN

        IMPORTS
                Counter
                        FROM RFC1155-SMI
                transmission
                        FROM RFC1213-MIB
                OBJECT-TYPE
                        FROM RFC-1212;

-- this is the MIB module for Parallel-printer-like
-- hardware devices

para    OBJECT IDENTIFIER ::= { transmission 34 }

-- the generic Parallel-printer-like group

-- Implementation of this group is mandatory for all
-- systems that have Parallel-printer-like hardware
-- ports supporting higher level services such as
-- character streams

paraNumber OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of ports (regardless of their current
        state) in the Parallel-printer-like port table."
    ::= { para 1 }

-- the Parallel-printer-like Port table

paraPortTable OBJECT-TYPE
    SYNTAX SEQUENCE OF ParaPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "A list of port entries.  The number of entries is
        given by the value of paraNumber."
    ::= { para 2 }

paraPortEntry OBJECT-TYPE
    SYNTAX ParaPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Status and parameter values for a port."
    INDEX { paraPortIndex }
    ::= { paraPortTable 1 }

ParaPortEntry ::=
    SEQUENCE {
        paraPortIndex
            INTEGER,
        paraPortType
            INTEGER,
        paraPortInSigNumber
            INTEGER,
        paraPortOutSigNumber
            INTEGER
    }

paraPortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "A unique value for each port.  Its value ranges
        between 1 and the value of paraNumber.  By
        convention and if possible, hardware port numbers
        map directly to external connectors.  The value for
        each port must remain constant at least from one
        re-initialization of the network management agent to
        the next."
    ::= { paraPortEntry 1 }

paraPortType OBJECT-TYPE
    SYNTAX INTEGER {
        other(1),
        centronics(2),
        dataproducts(3)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The port's hardware type."
    ::= { paraPortEntry 2 }

paraPortInSigNumber OBJECT-TYPE

    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of input signals for the port in the
        input signal table (paraPortInSigTable).  The table
        contains entries only for those signals the software
        can detect."
    ::= { paraPortEntry 3 }

paraPortOutSigNumber OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of output signals for the port in the
        output signal table (paraPortOutSigTable).  The
        table contains entries only for those signals the
        software can assert."
    ::= { paraPortEntry 4 }

-- the Input Signal table

paraInSigTable OBJECT-TYPE
    SYNTAX SEQUENCE OF ParaInSigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "A list of port input control signal entries."
    ::= { para 3 }

paraInSigEntry OBJECT-TYPE
    SYNTAX ParaInSigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Input control signal status for a hardware port."
    INDEX { paraInSigPortIndex, paraInSigName }
    ::= { paraInSigTable 1 }

ParaInSigEntry ::=
    SEQUENCE {
        paraInSigPortIndex
            INTEGER,
        paraInSigName
            INTEGER,
        paraInSigState

            INTEGER,
        paraInSigChanges
            Counter
    }

paraInSigPortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The value of paraPortIndex for the port to which
        this entry belongs."
    ::= { paraInSigEntry 1 }

paraInSigName OBJECT-TYPE
    SYNTAX INTEGER { power(1), online(2), busy(3),
                     paperout(4), fault(5) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Identification of a hardware signal."
    ::= { paraInSigEntry 2 }

paraInSigState OBJECT-TYPE
    SYNTAX INTEGER { none(1), on(2), off(3) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The current signal state."
    ::= { paraInSigEntry 3 }

paraInSigChanges OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of times the signal has changed from
        'on' to 'off' or from 'off' to 'on'."
    ::= { paraInSigEntry 4 }

-- the Output Signal table

paraOutSigTable OBJECT-TYPE
    SYNTAX SEQUENCE OF ParaOutSigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION

        "A list of port output control signal entries."
    ::= { para 4 }

paraOutSigEntry OBJECT-TYPE
    SYNTAX ParaOutSigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Output control signal status for a hardware port."
    INDEX { paraOutSigPortIndex, paraOutSigName }
    ::= { paraOutSigTable 1 }

ParaOutSigEntry ::=
    SEQUENCE {
        paraOutSigPortIndex
            INTEGER,
        paraOutSigName
            INTEGER,
        paraOutSigState
            INTEGER,
        paraOutSigChanges
            Counter
    }

paraOutSigPortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The value of paraPortIndex for the port to which
        this entry belongs."
    ::= { paraOutSigEntry 1 }

paraOutSigName OBJECT-TYPE
    SYNTAX INTEGER { power(1), online(2), busy(3),
                     paperout(4), fault(5) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Identification of a hardware signal."
    ::= { paraOutSigEntry 2 }

paraOutSigState OBJECT-TYPE
    SYNTAX INTEGER { none(1), on(2), off(3) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The current signal state."

    ::= { paraOutSigEntry 3 }

paraOutSigChanges OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of times the signal has changed from
        'on' to 'off' or from 'off' to 'on'."
    ::= { paraOutSigEntry 4 }

END