5. 定義

RFC1317-MIB DEFINITIONS ::= BEGIN
     IMPORTS
        Counter
                FROM RFC1155-SMI
        transmission
                FROM RFC1213-MIB
        OBJECT-TYPE
                FROM RFC-1212;

-- this is the MIB module for RS-232-like hardware devices

rs232    OBJECT IDENTIFIER ::= { transmission 33 }

-- the generic RS-232-like group

-- Implementation of this group is mandatory for all
-- systems that have RS-232-like hardware ports
-- supporting higher level services such as character
-- streams or network interfaces

rs232Number OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of ports (regardless of their current
        state) in the RS-232-like general port table."
    ::= { rs232 1 }

-- the RS-232-like general Port table

rs232PortTable OBJECT-TYPE
    SYNTAX SEQUENCE OF Rs232PortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "A list of port entries.  The number of entries is
        given by the value of rs232Number."
    ::= { rs232 2 }

rs232PortEntry OBJECT-TYPE
    SYNTAX Rs232PortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Status and parameter values for a port."
    INDEX { rs232PortIndex }
    ::= { rs232PortTable 1 }

Rs232PortEntry ::=
    SEQUENCE {
        rs232PortIndex
            INTEGER,
        rs232PortType
            INTEGER,
        rs232PortInSigNumber
            INTEGER,
        rs232PortOutSigNumber
            INTEGER,
        rs232PortInSpeed
            INTEGER,
        rs232PortOutSpeed
            INTEGER    }

rs232PortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "A unique value for each port.  Its value ranges
        between 1 and the value of rs232Number.  By
        convention and if possible, hardware port numbers
        map directly to external connectors.  The value for
        each port must remain constant at least from one
        re-initialization of the network management agent to
        the next."
    ::= { rs232PortEntry 1 }

rs232PortType OBJECT-TYPE
    SYNTAX INTEGER { other(1), rs232(2), rs422(3),
                     rs423(4), v35(5) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The port's hardware type."
    ::= { rs232PortEntry 2 }

rs232PortInSigNumber OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of input signals for the port in the
        input signal table (rs232PortInSigTable).  The table
        contains entries only for those signals the software
        can detect."
    ::= { rs232PortEntry 3 }

rs232PortOutSigNumber OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of output signals for the port in the
        output signal table (rs232PortOutSigTable).  The
        table contains entries only for those signals the
        software can assert."
    ::= { rs232PortEntry 4 }

rs232PortInSpeed OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The port's input speed in bits per second."
    ::= { rs232PortEntry 5 }

rs232PortOutSpeed OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The port's output speed in bits per second."
    ::= { rs232PortEntry 6 }

-- the RS-232-like Asynchronous Port group

-- Implementation of this group is mandatory if the system
-- has any asynchronous ports.  Otherwise it is not
-- present.

rs232AsyncPortTable OBJECT-TYPE
    SYNTAX SEQUENCE OF Rs232AsyncPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "A list of asynchronous port entries.  The maximum
        entry number is given by the value of rs232Number.
        Entries need not exist for synchronous ports."
    ::= { rs232 3 }

rs232AsyncPortEntry OBJECT-TYPE
    SYNTAX Rs232AsyncPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Status and parameter values for an asynchronous
        port."
    INDEX { rs232AsyncPortIndex }
    ::= { rs232AsyncPortTable 1 }

Rs232AsyncPortEntry ::=
    SEQUENCE {
        rs232AsyncPortIndex
            INTEGER,
        rs232AsyncPortBits
            INTEGER,
        rs232AsyncPortStopBits
            INTEGER,
        rs232AsyncPortParity
            INTEGER,
        rs232AsyncPortAutobaud
            INTEGER,
        rs232AsyncPortParityErrs
            Counter,
        rs232AsyncPortFramingErrs
            Counter,
        rs232AsyncPortOverrunErrs
            Counter

    }

rs232AsyncPortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "A unique value for each port.  Its value is the
        same as rs232PortIndex for the port."
    ::= { rs232AsyncPortEntry 1 }

rs232AsyncPortBits OBJECT-TYPE
    SYNTAX INTEGER (5..8)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The port's number of bits in a character."
    ::= { rs232AsyncPortEntry 2 }

rs232AsyncPortStopBits OBJECT-TYPE
    SYNTAX INTEGER { one(1), two(2),
                     one-and-half(3), dynamic(4) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The port's number of stop bits."
    ::= { rs232AsyncPortEntry 3 }

rs232AsyncPortParity OBJECT-TYPE
    SYNTAX INTEGER { none(1), odd(2), even(3),
                     mark(4), space(5) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The port's sense of a character parity bit."
    ::= { rs232AsyncPortEntry 4 }

rs232AsyncPortAutobaud OBJECT-TYPE
    SYNTAX INTEGER { enabled(1), disabled(2) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "A control for the port's ability to automatically
        sense input speed.

        When rs232PortAutoBaud is 'enabled', a port may
        autobaud to values different from the set values for
        speed, parity, and character size.  As a result a
        network management system may temporarily observe
        values different from what was previously set."
    ::= { rs232AsyncPortEntry 5 }

rs232AsyncPortParityErrs OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Total number of characters with a parity error,
        input from the port since system re-initialization
        and while the port state was 'up' or 'test'."
    ::= { rs232AsyncPortEntry 6 }

rs232AsyncPortFramingErrs OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Total number of characters with a framing error,
        input from the port since system re-initialization
        and while the port state was 'up' or 'test'."
    ::= { rs232AsyncPortEntry 7 }

rs232AsyncPortOverrunErrs OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Total number of characters with an overrun error,
        input from the port since system re-initialization
        and while the port state was 'up' or 'test'."
    ::= { rs232AsyncPortEntry 8 }

-- the RS-232-like Synchronous Port group

-- Implementation of this group is mandatory if the system
-- has any synchronous ports.  Otherwise it is not
-- present.

rs232SyncPortTable OBJECT-TYPE
    SYNTAX SEQUENCE OF Rs232SyncPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "A list of synchronous port entries.  The maximum
        entry number is given by the value of rs232Number.
        Entries need not exist for asynchronous ports."
    ::= { rs232 4 }

rs232SyncPortEntry OBJECT-TYPE
    SYNTAX Rs232SyncPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Status and parameter values for a synchronous
        port."
    INDEX { rs232SyncPortIndex }
    ::= { rs232SyncPortTable 1 }

Rs232SyncPortEntry ::=
    SEQUENCE {
        rs232SyncPortIndex
            INTEGER,
        rs232SyncPortClockSource
            INTEGER,
        rs232SyncPortFrameCheckErrs
            Counter,
        rs232SyncPortTransmitUnderrunErrs
            Counter,
        rs232SyncPortReceiveOverrunErrs
            Counter,
        rs232SyncPortInterruptedFrames
            Counter,
        rs232SyncPortAbortedFrames
            Counter
    }

rs232SyncPortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "A unique value for each port.  Its value is the
        same as rs232PortIndex for the port."
    ::= { rs232SyncPortEntry 1 }

rs232SyncPortClockSource OBJECT-TYPE
    SYNTAX INTEGER  { internal(1), external(2), split(3) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Source of the port's bit rate clock. 'split' means
        the tranmit clock is internal and the receive clock
        is external."
    ::= { rs232SyncPortEntry 2 }

rs232SyncPortFrameCheckErrs OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Total number of frames with an invalid frame check
        sequence, input from the port since system
        re-initialization and while the port state was 'up'
        or 'test'."
    ::= { rs232SyncPortEntry 3 }

rs232SyncPortTransmitUnderrunErrs OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Total number of frames that failed to be
        transmitted on the port since system
        re-initialization and while the port state was 'up'
        or 'test' because data was not available to the
        transmitter in time."
    ::= { rs232SyncPortEntry 4 }

rs232SyncPortReceiveOverrunErrs OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Total number of frames that failed to be received
        on the port since system re-initialization and while
        the port state was 'up' or 'test' because the
        receiver did not accept the data in time."
    ::= { rs232SyncPortEntry 5 }

rs232SyncPortInterruptedFrames OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Total number of frames that failed to be received
        or transmitted on the port due to loss of modem
        signals since system re-initialization and while the
        port state was 'up' or 'test'."
    ::= { rs232SyncPortEntry 6 }

rs232SyncPortAbortedFrames OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Number of frames aborted on the port due to
        receiving an abort sequence since system
        re-initialization and while the port state was 'up'
        or 'test'."
    ::= { rs232SyncPortEntry 7 }

-- the Input Signal table

rs232InSigTable OBJECT-TYPE
    SYNTAX SEQUENCE OF Rs232InSigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "A list of port input control signal entries."
    ::= { rs232 5 }

rs232InSigEntry OBJECT-TYPE
    SYNTAX Rs232InSigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Input control signal status for a hardware port."
    INDEX { rs232InSigPortIndex, rs232InSigName }
    ::= { rs232InSigTable 1 }

Rs232InSigEntry ::=
    SEQUENCE {
        rs232InSigPortIndex
            INTEGER,
        rs232InSigName
            INTEGER,
        rs232InSigState
            INTEGER,
        rs232InSigChanges
            Counter
    }

rs232InSigPortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The value of rs232PortIndex for the port to which
        this entry belongs."
    ::= { rs232InSigEntry 1 }

rs232InSigName OBJECT-TYPE
    SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
                     dcd(6), sq(7), srs(8), srts(9),
                     scts(10), sdcd(11) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Identification of a hardware signal, as follows:

            rts    Request to Send
            cts    Clear to Send
            dsr    Data Set Ready
            dtr    Data Terminal Ready
            ri     Ring Indicator
            dcd    Received Line Signal Detector
            sq     Signal Quality Detector
            srs    Data Signaling Rate Selector
            srts   Secondary Request to Send
            scts   Secondary Clear to Send
            sdcd   Secondary Received Line Signal Detector
        "
    REFERENCE
        "EIA Standard RS-232-C, August 1969."
    ::= { rs232InSigEntry 2 }

rs232InSigState OBJECT-TYPE
    SYNTAX INTEGER { none(1), on(2), off(3) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The current signal state."
    ::= { rs232InSigEntry 3 }

rs232InSigChanges OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of times the signal has changed from
        'on' to 'off' or from 'off' to 'on'."
    ::= { rs232InSigEntry 4 }

-- the Output Signal table

rs232OutSigTable OBJECT-TYPE
    SYNTAX SEQUENCE OF Rs232OutSigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "A list of port output control signal entries."
    ::= { rs232 6 }

rs232OutSigEntry OBJECT-TYPE
    SYNTAX Rs232OutSigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Output control signal status for a hardware port."
    INDEX { rs232OutSigPortIndex, rs232OutSigName }
    ::= { rs232OutSigTable 1 }

Rs232OutSigEntry ::=
    SEQUENCE {
        rs232OutSigPortIndex
            INTEGER,
        rs232OutSigName
            INTEGER,
        rs232OutSigState
            INTEGER,
        rs232OutSigChanges
            Counter
    }

rs232OutSigPortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The value of rs232PortIndex for the port to which
        this entry belongs."
    ::= { rs232OutSigEntry 1 }

rs232OutSigName OBJECT-TYPE
    SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
                     dcd(6), sq(7), srs(8), srts(9),
                     scts(10), sdcd(11) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Identification of a hardware signal, as follows:

            rts    Request to Send
            cts    Clear to Send
            dsr    Data Set Ready
            dtr    Data Terminal Ready
            ri     Ring Indicator
            dcd    Received Line Signal Detector
            sq     Signal Quality Detector
            srs    Data Signaling Rate Selector
            srts   Secondary Request to Send
            scts   Secondary Clear to Send
            sdcd   Secondary Received Line Signal Detector
        "
    REFERENCE
        "EIA Standard RS-232-C, August 1969."
    ::= { rs232OutSigEntry 2 }

rs232OutSigState OBJECT-TYPE
    SYNTAX INTEGER { none(1), on(2), off(3) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The current signal state."
    ::= { rs232OutSigEntry 3 }

rs232OutSigChanges OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of times the signal has changed from
        'on' to 'off' or from 'off' to 'on'."
    ::= { rs232OutSigEntry 4 }

END